A Checklist on safety and operational items shall be completed before
an experiment can start data taking. The following items must be
included in the pre experiment checklist. The Hall C Physics
Liaison is responsible for ensuring that the checklist has been
completed.
- [ ]
- VESDA system activated?
- [ ]
- Hydrogen sniffers not past calibration date?
- [ ]
- Manual valves between cryogenic targets and recovery tanks locked in
the open position before the targets are filled?
- [ ]
- All magnets equipped with functioning warning beacon?
- [ ]
- All magnet current leads covered by non-conductive or grounded shields?
- [ ]
- All of above shields equipped with properwarning signs?
- [ ]
- All magnet power supply doors are closed and properly interlocked?
- [ ]
- All power leads of fastbus power supplies covered by shields?
- [ ]
- Visual inspection of all vacuum windows performed?
- [ ]
- Dates of removal on tags of vacuum windows not expired or close to expiring?
- [ ]
- Proper warning signs installed close to all thin vacuum windows?
- [ ]
- Ear plugs available close to all thin vacuum windows?
- [ ]
- HMS shutter in HMS detector hut operational?
- [ ]
- Air-conditioning on in both HMS and SOS detector hut?
- [ ]
- Hardware switches installed to limit spectrometer rotation?
- [ ]
- HMS and SOS hardware angle limitations verified?
- [ ]
- HMS and SOS angle ranges loaded in rotation PLC?
- [ ]
- No oil leaks in SOS door hydraulics?
- [ ]
- Safety rails removed where they conflict with required angle ranges by experiment?