    keyword=organized run list from last nite's luminosity scan on Carbon

    The purpose of our 3rd and final luminosity scan on Carbon was to significantly improve the statistics for an HMS tracking-based analysis, acquire for the first time in FpiII enough SOS electron data to permit an SOS tracking-based analysis, and check yield versus computer deadtime in a controlled manner. All runs have 1 million events, consisting roughly of 1/3 million HMS e-, 1/3 million SOS e', and 1/3 million SOS pi-. (Each corresponds to about 0.18% statistics before track-finding and cuts.) Beam stability was excellent.
    I. LUMI-WISE LIST OF USEFUL RUNS
    (taken at roughly constant computer deadtime):
    
    Run     beamCurr      PS1   PS2   comments
            (microA)
    ----------------------------------------------
    
    47760   27            250   1     ~27% DT
    
    47761   53            500   2     ~28% DT
    
    47763   80            750   3     ~28% DT
    
    
    II. COMPUTER DEADTIME-WISE LIST OF USEFUL RUNS
    (ie, electronic and computer deadtime are controlled variables):
    
    47759   80            2000  8     ~11% DT
    
    47758   80            1000  4     ~22% DT
    
    47763   80            750   3     ~28% DT
    
    47757   80            500   2     ~44% DT     
    
    47764   80            250   1     ~55% DT
    
    
    III. LIST OF ALL RUNS IN THIS SERIES:
    
    Run     beamCurr      PS1   PS2   comments
            (microA)
    ------------------------------------------
    47755-6                           junk
    
    47757   80            500   2     ~44% DT     
    
    47758   80            1000  4     ~22% DT
    
    47759   80            2000  8     ~11% DT
    
    47760   27            250   1     ~27% DT
    
    47761   53            500   2     ~28% DT
    
    47762                             junk
    
    47763   80            750   3     ~28% DT
    
    47764   80            250   1     ~55% DT
    


    A copy of this log entry has been emailed to: hornt@jlab.org,blok@jlab.org,huberg@jlab.org