\documentclass{chowto} \title{Hall-C Base Equipment Checklist} \howtotype{user} % ``expert'', ``user'', ``reference'' %\experiment{Name of experiment} % Optional \author{H. Fenker} \category{general} % Subject area of this document %\maintainer{Name of person maintaining document} % Optional \date{April 4, 2003} % Can use \today as the argument \begin{document} \providecommand{\degg}{\ensuremath{^{\circ}\ }} \begin{abstract} This document provides the shift checklist covering the Hall-C base equipment. This checklist should be filled out at least once per eight-hour shift during experiment data-taking shifts, and at least once per 24-hour period during {\it Standby} shifts. Each experiment should modify and/or amend this checklist to satisfy its own particular needs. The checklist itself composes Section 2. You should make multiple copies of the pages of that section for shift workers to fill out. When all the columns on a printed copy have been filled in, the shift-checker should scan the pages into an hclog entry and file the paper copies in the checklist binder. The remaining sections provide guidance for filling out the checklist. {\bf Considerable effort was required to format the checklist tables for the printed version of this document. The tables do not reproduce well in the web version. To view the tables, get the postscript or pdf version of this document and print it.} \end{abstract} \section{Related {\it Howtos}} \begin{itemize} \item Monitoring HMS ``Utilities'' Systems. \cite{howto:hms_detector_monitoring} \item Drift Chamber Gas System \cite{howto:drift_gas_system} \item Monitoring the SOS Magnet System \cite{howto:sos_magnet_monitoring} \item Monitoring the HMS Magnet System \cite{howto:hms_magnet_monitoring} \item Reading the Ion Chambers and BLM's \cite{howto:ion_blm_reading} \item Remote Rotation of the HMS and SOS \cite{howto:spectrometer_rotation} \item Hall-C Analyzer \cite{howto:analyzer} \end{itemize} \section{Base Equipment Checklist} %============================================================================================= \small \textwidth=8.truein \textheight=10.0truein \hoffset=-1.0truein \pagestyle{empty} \newpage \subsection{Base Equipment Checklist -- Page 1 of 2} \begin{center} \begin{tabular}{|l|c|p{1.70cm}|p{1.70cm}|p{1.70cm}|p{1.70cm}|} \hline \hline DATE (month-day-year) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline Time (24 hour clock) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline Your Name &{\it Nominals} & ~ & ~ & ~ & ~ \\ \hline \hline \multicolumn{6}{|l|}{\bf Beam Conditions from Overview Screen, DAQ, MEDMs, and Scalers} \\ \hline Beam Energy (MeV) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline Beam Current &- - - - - - & ~ & ~ & ~ & ~ \\ \hline Rates on BLMs &- - - - - - & ~ & ~ & ~ & ~ \\ \hline &- - - - - - & ~ & ~ & ~ & ~ \\ \hline &- - - - - - & ~ & ~ & ~ & ~ \\ \hline &- - - - - - & ~ & ~ & ~ & ~ \\ \hline &- - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Trigger Rate (vis. scalers) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS Trigger Rate (vis. scalers) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Dead Time (vis. scalers) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS Dead Time (vis. scalers) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline IPM3H00A position (medm) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline IPM3H00B position (medm) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline Fast Raster Radius$_{max}$,Ix,Iy (medm) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline Slow Raster? (medm) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline M\o ller Target &~~OUT & ~ & ~ & ~ & ~ \\ \hline M\o ller LHe/LN2 Levels &~~$>70\%$ &~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline \hline \multicolumn{6}{|l|}{\bf Stats of Recently Replayed Run from files in the current experiment's online } \\ \multicolumn{6}{|l|}{\bf ~~~~~~replay directory, typically: $\sim$cdaq/{\it experiment}/replay/scalers/) } \\ \hline %gen{\it run\_number}.txt)} \\ \hline Run Number &- - - - - -& ~ & ~ & ~ & ~ \\ \hline HMS WC fiducial effi. &$>90\%$ & ~ & ~ & ~ & ~ \\ \hline SOS WC fiducial effi. &$>90\%$ & ~ & ~ & ~ & ~ \\ \hline Computer Deadtime &- - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Electronic Deadtime &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS Electronic Deadtime &- - - - - - & ~ & ~ & ~ & ~ \\ \hline \multicolumn{6}{|l|}{\bf Walk-through of Electronics Room} \\ \hline WC Thresholds HMS1/HMS2/SOS &5.5/5.5/5.2&~~~~/~~~~/&~~~~/~~~~/&~~~~/~~~~/&~~~~/~~~~/ \\ \hline Unser Monitor Temperature &$110\pm 1\degg C$ & ~ & ~ & ~ & ~ \\ \hline HMS Trigger (e.g. 3/4*anything) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS Trigger (e.g. 3/4*electron) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline \multicolumn{6}{|l|}{\bf Gas-Yard Checks (Gas Yard Key is \#29} \\ \hline Argon Manifold High/Low (PSI) &$>200/30$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline Ethane Manifold High/Low (PSI) &- - - - - -/$>20$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline Ethane Bottle Weights (lbs) &{\footnotesize $>[Full-30]$}&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline Helium bottle Pressure/Flow &$>200/1.5$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline \multicolumn{6}{|l|}{\bf Gas-Shed Checks (Gas Shed Key is \#29} \\ \hline SOS Flows: Ar CH1/Eth CH2 &0.15/0.15 {\it \footnotesize slpm}&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline HMS Flows: Ar CH3/Eth CH4 &0.3/0.3 {\it \footnotesize slpm}&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline HMS/SOS Fridge (degC) &$2\pm 1\degg C$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline Alcohol Bubbling? (HMS/SOS) &~y~/~y~ &~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline \end{tabular} \end{center} You can find this document as well as help for filling it out among the Hall-C {\it Howtos}~\cite{howto:base_equip_checklist}. %============================================================================================= \newpage \subsection{Base Equipment Checklist -- Page 2 of 2} \begin{center} \begin{tabular}{|l|c|p{1.70cm}|p{1.70cm}|p{1.70cm}|p{1.70cm}|} \hline \hline DATE (month-day-year) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline Time (24 hour clock) &- - - - - - & ~ & ~ & ~ & ~ \\ \hline &{\it Nominals} & ~ & ~ & ~ & ~ \\ \hline \hline \hline HMS/SOS Slits &- - - - - - &~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline Scattering Chamber Vacuum & $<10^-5$& ~ & ~ & ~ & ~ \\ \hline Target (material, length) & ~ & ~ & ~ & ~ & ~ \\ \hline HMS Shutter Open? & yes & ~ & ~ & ~ & ~ \\ \hline HMS angle (TV/GUI) &- - -/- - -&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline SOS angle (TV/GUI) &- - -/- - -&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline Hall Survey (TV) & OK & ~ & ~ & ~ & ~ \\ \hline HMS Cer. Temp/Press (TV) & $22\pm 3$/- - -& ~ & ~ & ~ & ~ \\ \hline SOS Door Closed? (TV) & yes & ~ & ~ & ~ & ~ \\ \hline SOS Cerenkov Pressure (TV) & $|P|<0.020$& ~ & ~ & ~ & ~ \\ \hline \hline \multicolumn{6}{|l|}{\bf High Voltages: HV {\it ON} and GUI Alarm {\it Enabled?}} \\ \hline HMS Hodoscopes / Drift Chambers &~$\surd ~~/~\surd$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline HMS Cerenkovs: Gas / Aerogel &~$\surd ~~/~\surd$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline HMS Pb-Glass &~$\surd ~~$& ~ & ~ & ~ & ~ \\ \hline \hline SOS Hodoscopes / Drift Chambers &~$\surd ~~/~\surd$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline SOS Cerenkovs: Gas / Aerogel &~$\surd ~~/~\surd$&~~~~~~/&~~~~~~/&~~~~~~/&~~~~~~/ \\ \hline SOS Pb-Glass / Lucite &~$\surd ~~/~\surd$&~~~~~~ &~~~~~~ &~~~~~~ &~~~~~~ \\ \hline \hline \multicolumn{6}{|l|}{\bf Spectrometer Magnets} \\ \hline HMS Q1 Current: $\pm$ setpt & - - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Q2 Current: $\pm$ /setpt & - - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Q3 Current: $\pm$ /setpt & - - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Q1 Hall Field: $\pm$ reading & - - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Q2 Hall Field: $\pm$ reading & - - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS Q3 Hall Field: $\pm$ reading & - - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS D Current: $\pm$ readback & - - - - - - & ~ & ~ & ~ & ~ \\ \hline HMS D NMR Field: $\pm$ readback & - - - - - - & ~ & ~ & ~ & ~ \\ \hline \hline HMS Q1 N2/He Level (\%) &{\footnotesize$>70~ / >70$}& ~ & ~ & ~ & ~ \\ \hline HMS Q2 N2/He Level (\%) &{\footnotesize$>70~ / >70$}& ~ & ~ & ~ & ~ \\ \hline HMS Q3 N2/He Level (\%) &{\footnotesize$>70~ / >70$}& ~ & ~ & ~ & ~ \\ \hline HMS D N2/He Level (\%) &{\footnotesize$>70~ / >70$}& ~ & ~ & ~ & ~ \\ \hline \hline SOS Q Current polarity/setpt &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS B1 Current polarity/setpt &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS B2 Current polarity/setpt &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS Q Hall Field &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS B1 Hall Field &- - - - - - & ~ & ~ & ~ & ~ \\ \hline SOS B2 Hall Field &- - - - - - & ~ & ~ & ~ & ~ \\ \hline \hline \multicolumn{6}{|l|}{\bf Enter Screen Snapshots of the Following Screens in {\it hclog}} \\ \hline BPM medm screen &~~~$\surd$ & ~ & ~ & ~ & ~ \\ \hline BCM medm screen &~~~$\surd$ & ~ & ~ & ~ & ~ \\ \hline \hline \multicolumn{5}{|r|}{\bf Scan this sheet into {\it hclog} when full. $\longrightarrow$}& ~ \\ \hline Check List Complete ({\it Initial})& xyz & ~ & ~ & ~ & ~ \\ \hline \end{tabular} \end{center} You can find this document as well as help for filling it out among the Hall-C {\it Howtos} \cite{howto:base_equip_checklist}. \clearpage %============================================================================================= \section{Help with Check List Items} \subsection{Help with Page 1} \small \flushleft \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline What & Where to find it & How to do it \\ \hline \hline DATE (month-day-year) & As given by Run Control & Enter as MM/DD/YY \\ \hline Time (24 hour clock) & As given by Run Control & Write the time into the cell \\ \hline Your Name & As given by your parents & Write legibly \\ \hline \hline \multicolumn{3}{|l|}{\bf Beam Conditions from Overview Screen, DAQ, MEDMs, and Scalers} \\ \hline \raggedright Beam Energy (MeV) & Large TV monitor on top of console, displaying accelerator program. & Get the beam energy of Hall C and write it down \\ \hline \raggedright Beam Current & Xterm on the far top-left. Look for the BCM screen. The two values indicate two different measurements and should be similar. & Write the beam current in the cell. \\ \hline \raggedright Rates on BLM's & Check rates on Upstream and Downstream BLM. On cdaqs1: run scaler\_display & Write down rates for the BLMs \\ \hline \raggedright HMS Trigger Rate (vis. scalers) & Red digital readouts in the right-center of the console.& How many HMS triggers occur over roughly 10 sec.? Divide by 10 and write down the result. \\ \hline \raggedright SOS Trigger Rate (vis. scalers) & Red digital readouts in the right-center of the console.& How many SOS triggers occur over roughly 10 sec.? Divide by 10 and write down the result. \\ \hline \raggedright HMS Dead Time (vis. scalers) & Red digital readouts in the right-center of the console.& Compute: 1-[(HMS~trigger)/(HMS~pretrigger)] Write it in the field. \\ \hline \raggedright SOS Dead Time (vis. scalers) & Red digital readouts in the right-center of the console.& Compute: 1-[(SOS~trigger)/(SOS~pretrigger)] Write it in the field. \\ \hline \raggedright IPM3H00A nominal? (medm) & Xterm on the fartop- left. Look for the BPM screen.& Record the displayed beam position. Compare it with the nominal position posted on the white board or sticky note. \\ \hline \raggedright IPM3H00B nominal? (medm) & Xterm on the fartop- left. Look for the BPM screen.& Record the displayed beam position. Compare it with the nominal position posted on the white board or sticky note. \\ \hline \raggedright Fast Raster R$_{max}$,Ix,Iy (medm) & Xterm on the top of the right console. Look for the raster\_hlc\_FR window.& In the ``set spiral magnet current'' field, record: R$_{max}$= Radius(mm) Ix=MRAT301H Iy=MRAT301V\\ \hline \raggedright Slow Raster? (medm) & & \\ \hline \raggedright M\o ller Target & Xterm on the top of the left console. Find the target section of the M\o ller Polarimeter controls screen.& Unless a M\o ller run is in progress, the target should be retracted ($\sim -3.85$). \\ \hline \raggedright M\o ller LHe/LN2 Levels & Xterm on the top of the left console. Find the liquid levels on the M\o ller Cryogenics controls screen.& Record the helium and nitrogen liquid levels (percent). They should be near full if the M\o ller solenoid is being used. \\ \hline \end{tabular} %--------------------------------------------------------------------- \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline \multicolumn{3}{|l|}{\bf Stats of Recently Replayed Run (from files in the current experiment's online } \\ \multicolumn{3}{|l|}{\bf ~~~~~~replay directory, typically: $\sim$cdaq/{\it experiment}/replay/scalers/) } \\ \hline Run Number & See the RunControl window for the current run. Record items below for a recently taken and analyzed run.& Enter the run number which gives the results noted in the next few lines. \\ \hline HMS WC fiducial effi. & grep effic stats{\it run\_number}.txt& Record the number on the line labeled ``fid~effic'' \\ \hline SOS WC fiducial effi. & grep effic stats{\it run\_number}.txt& Record the number on the line labeled ``fid~effic'' \\ \hline Computer Deadtime & grep 'D.T.' hms{\it run\_number}.txt& Record the Computer deadtime. \\ \hline HMS Electronic Deadtime & grep 'D.T.' hms{\it run\_number}.txt& Record the Elec. deadtime. \\ \hline SOS Electronic Deadtime & grep 'D.T.' hms{\it run\_number}.txt& Record the Elec. deadtime. \\ \hline \end{tabular} %--------------------------------------------------------------------- \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline \multicolumn{3}{|l|}{\bf Walk-through of Electronics Room} \\ \hline \raggedright WC Thresholds HMS1/HMS2/SOS & Rack CH03B10. Three digital voltage readouts. Should be 5.5 v for both HMS chambers. 4.0 for SOS.& Record the values. \\ \hline \raggedright Unser Monitor Temperature & top of rack CH03B12, LED digits. Nominal 110 degrees.& Record the reading. \\ \hline \raggedright HMS Trigger (e.g. 3/4*anything) & CH03B07. NIM crate, third crate from top. Rightmost logic module. Top half.& Where is the coincidence level pin located? \\ \hline \raggedright SOS Trigger (e.g. 3/4*anything) & CH03B05. NIM crate, third crate from top. Rightmost logic module. Top half.& Where is the coincidence level pin located? \\ \hline \end{tabular} %--------------------------------------------------------------------- \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline \multicolumn{3}{|l|}{\bf Gas-Yard Checks (Gas Yard Key is \#29} \\ \hline \raggedright Argon Manifold High/Low (PSI) & Outside gas shed, under roof, right-center.& Record the two pressure gauge readings on the argon gas manifold. \\ \hline \raggedright Ethane Manifold High/Low (PSI) & Outside gas shed, under roof, on the right.& Record the two pressures on the ethane gas manifold.\\ \hline \raggedright Ethane Bottle Weights (lbs) & Outside gas shed, under roof, on the right.& Record the two bottle weights (digital scales). \\ \hline \raggedright Helium bottle Pressure/Flow & Outside gas shed, under roof, on the left.& Record the bottle pressure and the flowmeter reading. \\ \hline \end{tabular} %--------------------------------------------------------------------- \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline \multicolumn{3}{|l|}{\bf Gas-Shed Checks (Gas Shed Key is \#29} \\ \hline \raggedright SOS Flows: Ar CH1/Eth CH2 & Inside gas shed, on the CRT display - channels 1 and 2.& Record the values on the ``Actual flow'' line \\ \hline \raggedright HMS Flows: Ar CH3/Eth CH4 & Inside gas shed, on the CRT display - channels 3 and 4.& Record the values on the ``Actual flow'' line \\ \hline \raggedright HMS/SOS Fridge (degC) & Inside gas shed, digital temperature displays near top of left rack.& Record the temperatures. \\ \hline \raggedright Alcohol Bubbling? (HMS/SOS) & Inside gas shed, within refrigerator (left=SOS, right=HMS).& QUICKLY open/close door, verify that gas is bubbling through the alcohol inside the glass dome. \\ \hline \end{tabular} %--------------------------------------------------------------------- \subsection{Help with Page 2} \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline What & Where to find it & How to do it \\ \hline \hline DATE (month-day-year) & See what you wrote on page 1. & Enter it here, too.\\ \hline Time (24 hour clock) & See what you wrote on page 1. & Enter it here, too.\\ \hline \hline HMS/SOS Slits & telnet~hctsv7~2003 (HMS) or hctsv5~2005 (SOS). See instructions posted above ``SLOW~CONTROLS'' Xterm or see the Collimators {\it Howto} \cite{howto:slits}. & Determine and record the slit position as either PION or SIEVE or SMALL or LARGE. \\ \hline Scattering Chamber Vacuum & Target cryo screen. Ask target operator if needed.& Record the reading. \\ \hline Target (material, length) & Ask target operator.& Record which target is in the beam. \\ \hline HMS Shutter Open? & See the LEDs labeled ``HMS SHUTTER'' located above the ``DATA ACQUISITION'' terminal.& Shutter must be ``OUT'' when taking beam. \\ \hline HMS angle (TV/GUI) & TV Monitor 4 and Spectrometer Rotation GUI& Read the angle and write it down. TV and GUI should agree.\\ \hline SOS angle (TV/GUI) & TV Monitor and Spectrometer Rotation GUI& Read the angle and write it down. TV and GUI should agree. \\ \hline Hall Survey (TV) & Scan all the cameras in the hall looking for anything unusual.& Verify that you performed the inspection by checking off the box. \\ \hline HMS Cer. Temp/Press (TV) & Two LED readouts visible on TV monitor \#7. Select the camera labeled ``HMS CERENK''.& Record the values. \\ \hline SOS Door Closed? (TV) & Note this while doing hall TV survey. & SOS Door should be closed when using SOS. \\ \hline SOS Cerenkov Pressure (TV) & TV Monitor button labeled {\it SOS Cerenkov}& Record the differential pressure. If it is outside the range +0.020 to -0.020~psid, notify an SOS Cerenkov expert as the windows may be damaged. \\ \hline \hline \end{tabular} %--------------------------------------------------------------------- \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline \multicolumn{3}{|l|}{\bf High Voltages: HV {\it ON} and GUI Alarm {\it Enabled?}} \\ \hline All HMS Detectors & HMS HV GUI on SLOW CONTROLS xterm.& Verify that GUI is ``RUNNING'' and not indicating any bad channels. \\ \hline All SOS Detectors & SOS HV GUI on SLOW CONTROLS xterm.& Verify that GUI is ``RUNNING'' and not indicating any bad channels. \\ \hline \hline \end{tabular} %--------------------------------------------------------------------- \begin{tabular}{|p{2in}|p{2.5in}|p{2.5in}|} \hline \hline \multicolumn{3}{|l|}{\bf Spectrometer Magnets} \\ \hline HMS Q1,2,3 and D Currents: $\pm$ setpt & PC Monitor in center of control console. See HMS magnet controls {\it Howto} \cite{howto:hms_magnet_controls} for how to navigate.& Write down current polarities and setpoints. \\ \hline HMS Q1, Q2, Q3 Hall Fields: $\pm$ reading & On TV monitor \#5. Button labeled HMS~NMR (it's really a Hall probe). Top to bottom, the three numbers are Hall Probe readings for HMS Q1, Q2, Q3.& Write down the three numbers including sign. \\ \hline HMS D NMR Field: $\pm$ readback & PC Monitor in center of control console. See HMS magnet controls {\it Howto} \cite{howto:hms_magnet_controls} for how to navigate.& Write down the NMR readout. \\ \hline HMS Q1Q2, Q3, D N2/He Level & PC Monitor in center of control console. See HMS magnet controls {\it Howto} \cite{howto:hms_magnet_controls} for how to navigate.& Record He and N2 levels from their respective screens. \\ \hline SOS Q, B1, B2 Current polarity/setpt & telnet VMEC19 and run the program {\tt sos} (see posted instructions for username and password)& Record the readings for {\tt Polarity} and {\tt Current Setpoint} \\ \hline SOS Q, B1, B2 Hall Field & telnet VMEC19 and run the program {\tt sos} (see posted instructions for username and password)& Record the readings for {\tt Hall probe field} \\ \hline \hline Enter Screen Snapshots in {\it hclog} & Xterm on upper left of console. & Start an {\tt hclog} entry. Use the {\tt Grab Screen} and {\tt Grab 2nd Picture} buttons to add the required {\tt MEDM} displays to the log entry. \\ \hline \hline Scan this sheet into {\it hclog} when full. & Any Xterm booted on {\tt cdaqh1} & Place the sheet to be scanned on the scanner in rack CH03B08. Start an {\tt hclog} entry. Use the {\tt ScanIt!} button to scan the page, then use the {\tt Grab Screen} button to grab the display of the scan. \\ \hline \end{tabular} \end{document} % Revision history: adapted from existing checklist 3/10/03 by H. Fenker % $Log: base_equip_checklist.tex,v $ % Revision 1.5 2003/04/11 23:02:14 saw % (hcf) Corrected SOS gas flow rate nominals % % Revision 1.4 2003/04/11 14:15:57 saw % Use correct citation of slits/collimator howto % % Revision 1.3 2003/04/04 18:31:50 saw % (hcf) Add distinct terminal server for SOS slits % % Revision 1.2 2003/04/04 15:52:44 saw % (hcf) Improvments and formatting work % % Revision 1.1 2003/03/11 21:41:24 saw % Initial version. Adapted from existing checklist 3/10/03 by H Fenker %
Analyzer/Replay: Mark Jones, Documents: Stephen Wood |
Powered by ViewCVS 0.9.2-cvsgraph-1.4.0 |