Line 151 
Line 151 
                 the M\o ller collimators are within 0.05cm of their tune positions.                 the M\o ller collimators are within 0.05cm of their tune positions.
  
 \item {\bf Insert M\o ller Target}: from the M\o ller GUI, select target \item {\bf Insert M\o ller Target}: from the M\o ller GUI, select target
         2 (10 $\mu$m thick) or 3 (4 $\mu$m thick).          3 (4 $\mu$m thick).
         (You may also use target 1 (4 $\mu$m thick), but it is known to have pinholes          (You may also use target 2 (1 $\mu$m thick), but this is primarily intended
         in it which, in principle, could affect your rates and measurement.)          for high current tests.  NEVER insert target 1 unless specifically intructed
           to by an expert - this is the ``iron wire'' target that requires careful beam position
           tuning before use.)
  
 \item {\bf Raster}: NEVER take more than 2$\mu$A beam on a M\o ller target \item {\bf Raster}: NEVER take more than 2$\mu$A beam on a M\o ller target
         unless the M\o ller raster system is turned on-- and then only         unless the M\o ller raster system is turned on-- and then only
Line 326 
Line 328 
                 the M\o ller collimators are within 0.05cm of their tune positions.                 the M\o ller collimators are within 0.05cm of their tune positions.
  
 \item {\bf Insert M\o ller Target}: from the M\o ller GUI, select target \item {\bf Insert M\o ller Target}: from the M\o ller GUI, select target
         2 (10 $\mu$m thick) or 3 (4 $\mu$m thick).          3 (4 $\mu$m thick).
         (You may also use target 1 (4 $\mu$m thick), but it is known to have pinholes          (You may also use target 2 (1 $\mu$m thick), but this is primarily intended
         in it which, in principle, could affect your rates and measurement.)          for high current tests.  NEVER insert target 1 unless specifically intructed
           to by an expert - this is the ``iron wire'' target that requires careful beam position
           tuning before use.)
  
 \item {\bf Raster}: NEVER take more than 2$\mu$A beam on a M\o ller target \item {\bf Raster}: NEVER take more than 2$\mu$A beam on a M\o ller target
         unless the M\o ller raster system is turned on-- and then only         unless the M\o ller raster system is turned on-- and then only
Line 424 
Line 428 
  
 % Revision history: % Revision history:
 % $Log$ % $Log$
   % Revision 1.2  2003/11/18 14:44:38  saw
   % (djg) Changed description of target configuration to reflect hardware changes.
   %
 % Revision 1.1  2003/06/12 16:16:47  saw % Revision 1.1  2003/06/12 16:16:47  saw
 % Copied from existing document by hcf 5/6/03 % Copied from existing document by hcf 5/6/03
 % %