Often, the screen is hanged up. When the status doesn't change, close the screen
and reopen it.
After a power down and a recycling, we need to adjust the zero(0.0) position.
> Push the button of 'Go home'.
> In case of '+limit latched',
push the button of '-10 mm' and 'Go home'
> In case of '-limit latched',
push move +300 mm with the button of '+10 mm' and 'Go home'
If the target does not move, check the second column for the current position on the screen.
The background color is 'pink' in case of No fault and is 'red' in case of something fault.
If the color is red, you need to cycle power for the controller which is located
behind the 'Splitter' power supply. After you go into HAllC, check the controller box.
In the right side, see LED lights of 'Disable/short'. If the LED is red, it means 'Amp fault'.
Anyway, In the behind of the rack, there is a plug labeled 'TARGET'. Unplug and plug it for
power cycling. For a test, push the bottom of '+1mm' and confirm the problem is solved.
Do not forget the zero adjustment.