Operation parameters for HKS magnets

From Hchkswiki
Revision as of 11:46, 18 August 2009 by Nakamura (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

This is a summary of HKS TOSCA calculation fot Geant4 simulation.

Last modified : May13, 2009

                                  KQ1          KQ2          KD       
Bacic Parameters
Max. Current (A)                  875          450          1140
Number of Turn                    64           80           256
Total Current (A)                 56000        36000        291840
Parameters in TOSCA
Scaling Factor                    0.48         0.65         0.911
Current in Model (A)              420.00       292.50       1038.54
Total Current in Model (A)        26789.94086  23399.97537  265863.0894
TOSCA Analysis Results
Model File (.op3)                 KQ1_48       KQ2_65       KD_30Jan09_0911
Map File (.table)                 KQ1_48       KQ2_65       KD_30Jan09_0911
Field Strength in TOSCA           445.291 g/cm 275.805 g/cm 14447 g
Calculated value from BI curve    -       g/cm -       g/cm - g
HP/NMR coordinate (cm)            To be filled To be filled To be filled


KD-BI.jpg

KQ1-GI.jpg

KQ2-GI.jpg