Targets & Target Control
Here is drawings of water cell target test.Media:WCT-Test.pdf
Solid Targets Design of the plate for targets mount. Media:Ladder-Plate.pdf
Quotation of enriched Li6 and Li7 Media:QuoteLi6-7.pdf
- Lithium target should avoid air!
Li in moisture air in even room temperature reacts with nitrogen. 6 Li + 3 N_2 -> 2 Li_3N Lithium nitrode reacts with water in room temperature, and gives lithium hydroxide (white solid) and ammonia Li_3N + 3 H_2O -> 3 LiOH + NH_3 Therefore, Li left in air for a while will be white and smell bad.
- Targets list in hand
E01-011 Solid targets on the ladder : Stored at Radiation Container
- 1 BeO
- 2 Li7 DISPOSED
- 3 Pb
- 4 Li6 DISPOSED
- 5 B10
- 6 Si28 (65mg/cm2, enriched)
Enriched Li7 and Li6 : ordered by Dave.
At C110
Si28 (from Russia, 80mg/cm2) Y89 V51
Cr52 (enriched from Sugai-san)
C12 BeO (0.5 mm)
Si28 (from Russia), Si(nat) B10 B11 two pieces Lots of Be9 (1mm thick)
Operation You can boot the control GUI by following procedure;
*Login to any cdaq machines (cdaql1 - cdaql6) by cvxwrks account. Password is same as cdaq's one (you might find if you look the white board at counting room). *"> cd /home/cvxwrks/hksEpics/R3.14.6/base/hksApp/src/" (location might be change) *">./sst-control.tcl"
, then pop a GUI window up as shown follows. HKS and HES Sieve Slit control menus are also listed on the window, but never click control buttons except for authorized users.
There are three categories on the GUI menu; Position, Control List and Status. The position indicates where beam hits on the ladder. if the position indicates similar value on the control button, it means beam hits that target. Twelve buttons are listed on the control category; home, water cell and six solid targets #1 - #6 in position, +-1mm move for the fine tuning, all out for target folder exchange and emergency stop. The ladder inserts from left side of the beamline. Water cell and #1 - #6 solid targets are located from right to left. + direction is the ladder in and - direction is out.