    Run #33239 (sosonly) - /cdaqs1/data1/hnss_33239.log

    Beam Energy (MeV) 17281721
    SOS Momentum (GeV/c) 1.1201.120
    SOS Angle -1.001.85
    Target NUMBER 44
    SOS Q Set Current 401.91401.91
    SOS Q Field 6449.006449.00
    SOS B1 Set Current 528.19528.19
    SOS B1 Hall Probe 12759.5012759.50
    SOS B2 Set Current 448.86448.86
    SOS B2 Hall Probe -12991.50-12991.50
    Splitter Set Current 370.36700370.36700
    Splitter Current Readback 370.108370.108
    Enge Set Current 319.40319.40
    Enge Current Readback 317.35317.26

    C12 production run

    4/4*ACbar*GCbar*SHLObar (A+B)
    Collimator: Large
    Beam current: 0.6 uA
    ps1=1 ps2=1

    SSD bias voltage = 80 V,
    SSD vth's are 340 mV