0000 | 0100 | 0200 | 0300 | 0400 | 0500 | 0600 | 0700 | Total Time | |
---|---|---|---|---|---|---|---|---|---|
Acceptable Beam in Use | 21 | 45 | 38 | 0.0 | 17 | 45 | 53 | 60 | 4.65 |
Beam Available but Not in Use | 39 | 0 | 22 | 60 | 38 | 0 | 7 | 0.0 | 2.77 |
Beam Not Available or Unacceptable | 0 | 15 | 0 | 0 | 5 | 15 | 0 | 0 | 0.58 |
Accelerator Con- figuration Chage | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.00 |
Experiment Ready | 21 | 60 | 38 | 0.0 | 22 | 60 | 53 | 60 | 5.23 |
Planned Config- uration Change | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.00 |
Unplanned Experiment Down | 39 | 0 | 22 | 60 | 38 | 0 | 7 | 0 | 2.77 |
Hall not ready reasons | |||||||||
Target | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.00 |
HMS | 39 | 0 | 22 | 60 | 38 | 0 | 0 | 0 | 2.65 |
Npol | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.00 |
Data Acq | 0 | 0 | 0 | 0 | 0 | 0 | 7 | 0 | 0.12 |
Other | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | 0.00 |
Comments: 00:39 Q2 back, taking data. 01:38 Beam off, MCC will do Q measurement. 01:53 Beam back, taking data. 02:38 Q2 problem, He level very low. 04:38 Q2 back, taking data. 04:55-05:15 was no beam. 06:01 DAQ problem, reboot TSO.
Data Entry by: hamlet