Beam Energy (MeV) | 2.33 | 2.33 |
HMS Momentum (GeV/c) | 1.9627 | 1.9627 |
HMS Angle | -1084.42 | -1084.42 |
Q1 Set Current | 254.975 | 254.975 |
Q2 Set Current | -202.500 | -202.500 |
Q3 Set Current | 98.889 | 98.889 |
Q1 B Field (G) | 3499.0000 | 3499.0000 |
Q2 B Field (G) | -4118.4000 | -4118.4000 |
Q3 B Field (G) | 1980.0000 | 1980.0000 |
D Current Readback | -600.750 | -600.750 |
B_true | -0.5378478 | -0.5378478 |
Target Encoder | 39678 | 39678 |
Target Insert (a - d) | 0 | 0 |
Target Position (-1 - 7) | 1 | 1 |
Target Polarization | -31.4 | -31.4 |
Target Field (T) | 5.003 | 5.003 |
Targ Acc Charge (10^15 e-) | 0.000 | 0.000 |
Beam Current (nA) | ~100 | ~100 |
SEM pos x,y (mm) | 0.9,0.2 | 0.9,0.2 |
SEM dia x,y (mm) | 19.2,19.9 | 19.2,19.9 |
Fast Raster dia (mm) | 0.5 | 0.5 |
ND3 bottom, Pol=-31.4, threshold=25 mv