Jefferson Lab Hall C Logbook for August 01 - Run Starts
Main INDEX
Friday
39680 08/31/01 11:45 cdaq Run 41308: cosmics runs
39670 08/31/01 07:09 cdaq Run 41307: COSMICS
39668 08/31/01 07:05 cdaq Run 41306: ND3 top cell,P_t=+13.4%,FR=2.4A,SR=7.2,launch angle=4.41, half plate in
39665 08/31/01 06:24 cdaq Run 41305: ND3 top cell,P_t=+13.4%,FR=2.4A,SR=7.2,launch angle=4.41, half plate in
39662 08/31/01 05:30 cdaq Run 41304: ND3 top cell,P_t=+14.2%,FR=2.4A,SR=7.2,launch angle=4.41, half plate in
39659 08/31/01 04:44 cdaq Run 41303: ND3 top cell,P_t=+14.4%,FR=2.4A,SR=7.2,launch angle=4.41
39656 08/31/01 03:58 cdaq Run 41302: ND3 top cell,P_t=+14.4%,FR=2.4A,SR=7.2,launch angle=4.41
39654 08/31/01 03:08 cdaq Run 41301: ND3 top cell,P_t=+15.7%,FR=2.4A,SR=7.2,launch angle=4.41
39650 08/31/01 02:11 cdaq Run 41300: ND3 top cell,P_t=+16.7%,FR=2.4A,SR=7.2,launch angle=4.41
39647 08/31/01 01:29 cdaq Run 41299: ND3 top cell,P_t=+16.7%,FR=2.4A,SR=7.2,launch angle=4.41
39643 08/31/01 00:37 cdaq Run 41298: ND3 top cell,P_t=+17.6%,FR=2.4A,SR=7.2,launch angle=4.41
Thursday
39636 08/30/01 23:40 cdaq Run 41297: ND3 bottom cell,P_t=+18.6%,FR=2.4A,SR=7.2,launch angle=4.41
39634 08/30/01 22:58 cdaq Run 41296: ND3 bottom cell,P_t=+19.4%,FR=2.4A,SR=7.2,launch angle=4.41
39629 08/30/01 22:05 cdaq Run 41295: ND3 bottom cell,P_t=+22.5%,FR=2.4A,SR=7.2,launch angle=4.41
39625 08/30/01 21:47 cdaq Run 41294: ND3 bottom cell,P_t=+20.5%,FR=2.4A,SR=7.2,launch angle=4.41
39621 08/30/01 20:53 cdaq Run 41293: ND3 bottom cell,P_t=+21.6%,FR=2.4A,SR=7.2,launch angle=4.41
39619 08/30/01 20:11 cdaq Run 41292: ND3 bottom cell,P_t=+22.6%,FR=2.4A,SR=7.2,launch angle=4.41
39614 08/30/01 19:21 cdaq Run 41291: ND3 bottom cell,P_t=+24.2%,FR=2.4A,SR=7.2,launch angle=4.41
39608 08/30/01 18:28 cdaq Run 41290: ND3 bottom cell,P_t=+24.6%,FR=2.4A,SR=7.2,launch angle=4.41
39607 08/30/01 18:18 cdaq Run 41289: ND3 bottom cell,P_t=+24.7%,FR=2.4A,SR=7.2,launch angle=4.41
39601 08/30/01 17:26 cdaq Run 41288: ND3 bottom cell,P_t=+25.4%,FR=2.4A,SR=7.2,launch angle=4.41
39594 08/30/01 14:58 cdaq Run 41286: MT target,FR=2.4A,SR=7.2,launch angle=4.41
39592 08/30/01 13:58 cdaq Run 41285: 12C,FR=2.4A,SR=7.2,launch angle=4.41
39589 08/30/01 13:12 cdaq Run 41284: 12C,FR=2.4A,SR=7.2,launch angle=4.41
39586 08/30/01 12:11 cdaq Run 41283: ND3 top cell,P_t=-20.4%,FR=2.4A,SR=7.2,launch angle=4.41
39584 08/30/01 11:18 cdaq Run 41282: ND3 top cell,P_t=-22.0%,FR=2.4A,SR=7.2,launch angle=4.41
39581 08/30/01 10:21 cdaq Run 41281: ND3 top cell,P_t=-22.0%,FR=2.4A,SR=7.2,launch angle=4.41
39579 08/30/01 09:30 cdaq Run 41280: ND3 top cell,P_t=-22.0%,FR=2.4A,SR=7.2,launch angle=4.41
39575 08/30/01 08:33 cdaq Run 41279: ND3 top cell,P_t=-22.0%,FR=2.4A,SR=7.2,launch angle=4.41
39570 08/30/01 07:45 cdaq Run 41278: ND3 top cell,P_t=-22.0%,FR=2.4A,SR=7.2,launch angle=4.41
39564 08/30/01 06:52 cdaq Run 41277: ND3 top cell,P_t=-22.2%,FR=2.4A,SR=7.2,launch angle=4.41
39561 08/30/01 06:01 cdaq Run 41276: ND3 top cell,P_t=-22.5%,FR=2.4A,SR=7.2,launch angle=4.41
39558 08/30/01 05:31 cdaq Run 41275: ND3 top cell,P_t=-22.7%,FR=2.4A,SR=7.2,launch angle=4.41
39554 08/30/01 04:40 cdaq Run 41274: ND3 top cell,P_t=-23.5%,FR=2.4A,SR=7.2,launch angle=4.41
39553 08/30/01 04:38 cdaq Run 41273: ND3 top cell,P_t=-23.5%,FR=2.4A,SR=7.2,launch angle=4.41
39552 08/30/01 04:29 cdaq Run 41272: ND3 top cell,P_t=-23.5%,FR=2.4A,SR=7.2,launch angle=4.41
39551 08/30/01 04:08 cdaq Run 41271: ND3 top cell,P_t=-23.3%,FR=2.4A,SR=7.2,launch angle=4.41
39547 08/30/01 03:14 cdaq Run 41270: ND3 top cell,P_t=-23.7%,FR=2.4A,SR=7.2,launch angle=4.41
39541 08/30/01 02:25 cdaq Run 41269: ND3 top cell,P_t=-24.1%,FR=2.4A,SR=7.2,launch angle=4.41
39539 08/30/01 02:22 cdaq Run 41268: ND3 top cell,P_t=-24.1%,FR=2.4A,SR=7.2,launch angle=4.41
39537 08/30/01 02:15 cdaq Run 41267: ND3 top cell,P_t=-27.7%,FR=2.4A,SR=7.2,launch angle=4.4, Current 110 nA
39534 08/30/01 02:08 cdaq Run 41266: ND3 top cell,P_t=-27.7%,FR=2.4A,SR=7.2,launch angle=4.4, Current 90 nA
39528 08/30/01 00:54 cdaq Run 41264: ND3 top cell,P_t=-27.3%,FR=2.4A,SR=7.2,launch angle=4.41
39521 08/30/01 00:00 cdaq Run 41263: ND3 top cell,P_t=-27.0%,FR=2.4A,SR=7.2,launch angle=4.41
Wednesday
39519 08/29/01 23:40 cdaq Run 41262: ND3 top cell,P_t=-27.7%,FR=2.4A,SR=7.2,launch angle=4.41
39516 08/29/01 23:02 cdaq Run 41261: ND3 top cell,P_t=-27.0%,FR=2.4A,SR=7.2,launch angle=4.41
39513 08/29/01 21:58 cdaq Run 41259: ND3 top cell,P_t=-26.5%,FR=2.4A,SR=7.2,launch angle=4.41
39510 08/29/01 21:15 cdaq Run 41258: ND3 top cell,P_t=-27.0%,FR=2.4A,SR=7.2,launch angle=4.41
39508 08/29/01 20:27 cdaq Run 41257: ND3 top cell,P_t=-27.3%,FR=2.4A,SR=7.2,launch angle=4.41
39505 08/29/01 19:36 cdaq Run 41256: ND3 top cell,P_t=-27.8%,FR=2.4A,SR=7.2,launch angle=4.41
39503 08/29/01 18:59 cdaq Run 41255: ND3 top cell,P_t=-28.1%,FR=2.4A,SR=7.2,launch angle=4.41
39499 08/29/01 18:09 cdaq Run 41254: ND3 top cell,P_t=-29.8,FR=2.4A,SR=7.2,launch angle=4.41
39469 08/29/01 13:24 cdaq Run 41238: ND3 top cell,P_t=-29.5,FR=2.4A,SR=7.2,launch angle=4.41
39466 08/29/01 12:45 cdaq Run 41237: ND3 top cell,P_t=-29.8,FR=2.4A,SR=7.2,launch angle=4.41
39461 08/29/01 11:55 cdaq Run 41236: ND3 top cell,P_t=-30.7,FR=2.4A,SR=7.2,launch angle=4.41
39459 08/29/01 11:47 cdaq Run 41235: raster check
39457 08/29/01 11:19 cdaq Run 41234: ND3 top cell,P_t=-31.2,FR=2.4A,SR=7.2,launch angle=4.41
39452 08/29/01 10:17 cdaq Run 41233: ND3 top cell,P_t=-30.8,FR=2.4A,SR=7.2,launch angle=4.41
39449 08/29/01 09:40 cdaq Run 41232: ND3 top cell,P_t=-31.7,FR=2.4A,SR=7.2,launch angle=4.41
39443 08/29/01 08:39 cdaq Run 41231: ND3 top cell,P_t=-33.2,FR=2.4A,SR=7.2,launch angle=4.41
39437 08/29/01 07:33 cdaq Run 41230: ND3 top cell,P_t=-38.6,FR=2.4A,SR=7.2,launch angle=4.41
39432 08/29/01 06:07 cdaq Run 41229: ND3 top cell,P_t=-26.4,FR=2.4A,SR=7.2,launch angle=4.41
39429 08/29/01 03:06 cdaq Run 41227: Carbon target , launch angle 4.41, I=100na
39427 08/29/01 02:11 cdaq Run 41226: Carbon target , launch angle 4.41, I=100na
39425 08/29/01 00:59 cdaq Run 41225: Empty target , launch angle 4.41, I=100na
Tuesday
39420 08/28/01 23:12 cdaq Run 41224: Empty target , launch angle 4.41, I=100na
39415 08/28/01 19:58 cdaq Run 41221: bottom target , t.p =-19.5%, launch angle 4.41, I=100na
39412 08/28/01 19:14 cdaq Run 41220: bottom target , t.p =-19.5%, launch angle 4.41, I=100na
39408 08/28/01 18:23 cdaq Run 41219: bottom target , t.p =-20.5%, launch angle 4.41, I=100na
39405 08/28/01 17:26 cdaq Run 41218: bottom target , t.p =-21.1%, launch angle 4.41, I=100na
39401 08/28/01 16:46 cdaq Run 41217: bottom target , t.p =-20.9%, launch angle 4.41, I=100na
39400 08/28/01 16:40 cdaq Run 41216: bottom target , t.p =-20.9%, launch angle 4.41, I=100na
39393 08/28/01 15:37 cdaq Run 41212: bottom ND3 , Pt = -21.8 %, launch angle 4.41, I=100na
39389 08/28/01 14:44 cdaq Run 41211: bottom ND3 , Pt = -24.3 %, launch angle 4.41, I=100na
39386 08/28/01 13:45 cdaq Run 41210: bottom ND3 , Pt = -24.6 %, launch angle 4.41, I=100na
39383 08/28/01 12:04 cdaq Run 41209: bottom target , Pt = -29.9 %, launch angle 4.41, I=100na
39375 08/28/01 10:06 cdaq Run 41208: COSMICS
39372 08/28/01 09:08 cdaq Run 41207: top target , t.p 21.7 %, launch angle 4.41, I=100na
39366 08/28/01 07:50 cdaq Run 41206: top target , t.p . 23.5%, launch angle 4.41, I=100na
39362 08/28/01 06:51 cdaq Run 41205: top target , t.p . 22.6%, launch angle 4.41, I=100na
39357 08/28/01 05:53 cdaq Run 41203: top target , t.p . 25.1%, launch angle 4.41, I=100na
39354 08/28/01 05:14 cdaq Run 41202: top target , t.p . 23.0%, launch angle 4.41, I=100na
39352 08/28/01 04:23 cdaq Run 41201: top target , t.p . 23.5%, launch angle 4.41, I=100na
39349 08/28/01 03:31 cdaq Run 41200: top target , t.p . 24.5%, launch angle 4.41, I=100na
39347 08/28/01 02:36 cdaq Run 41199: top target , t.p . 24.4%, launch angle 4.41, I=100na
39344 08/28/01 01:48 cdaq Run 41198: top target , t.p . 26.6%, launch angle 4.41, I=100na
39341 08/28/01 00:47 cdaq Run 41197: top target , t.p . 29.2%, launch angle 4.41, I=100na
Monday
39335 08/27/01 23:54 cdaq Run 41196: top target , t.p . 29.1%, launch angle 4.41, I=100na
39332 08/27/01 23:24 cdaq Run 41195: top target , t.p . 25.8%, launch angle 4.41, I=100na
39329 08/27/01 22:22 cdaq Run 41194: top target , t.p . 26.6%, launch angle 4.41, I=100na
39327 08/27/01 21:28 cdaq Run 41193: top target , t.p . 27.4%, launch angle 4.41, I=100na
39324 08/27/01 20:45 cdaq Run 41192: top target , t.p . 27.7%, launch angle 4.41, I=100na
39321 08/27/01 19:57 cdaq Run 41191: top target , t.p . 28.2%, launch angle 4.41, I=100na
39317 08/27/01 19:04 cdaq Run 41190: top target , t.p . 31.4%, launch angle 4.41, I=100na
39315 08/27/01 18:25 cdaq Run 41189: top target , t.p . 31.9 %, launch angle 4.41, I=100na
39312 08/27/01 17:24 cdaq Run 41188: top target , t.p . 33.6 %
39308 08/27/01 16:41 cdaq Run 41187: Cosmics run
39302 08/27/01 15:45 cdaq Run 41186: top ND3, Pt = 31.5%, I=100 nA, FR=2.4, SR=7.2
39298 08/27/01 14:56 cdaq Run 41185: top ND3, Pt = 32.7%, I=100 nA, FR=2.4, SR=7.2
39296 08/27/01 14:13 cdaq Run 41184: top ND3, Pt = 34.5%, I=100 nA, FR=2.4, SR=7.2
39291 08/27/01 13:21 cdaq Run 41183: top ND3, Pt = 36.5%, I=100 nA, FR=2.4, SR=7.2
39288 08/27/01 12:15 cdaq Run 41182: ND3 top.
39285 08/27/01 11:52 cdaq Run 41181: ND3 top.
39279 08/27/01 10:57 cdaq Run 41179: ND3 top target.
39277 08/27/01 10:38 cdaq Run 41178: ND3 top. Previous run had ROC2 crash at end.
39273 08/27/01 10:07 cdaq Run 41177: Top ND3 target
39265 08/27/01 07:21 cdaq Run 41176: Cosmics
39258 08/27/01 04:17 cdaq Run 41174: Carbon Target
39255 08/27/01 03:58 cdaq Run 41173: Carbon Target
39252 08/27/01 03:23 cdaq Run 41172: Carbon Target
39250 08/27/01 03:13 cdaq Run 41171: Carbon Target
39247 08/27/01 00:05 cdaq Run 41169: bottom ND3, Pt = 20.0%, I=100 nA, FR=2.4, SR=7.2
Sunday
39242 08/26/01 23:12 cdaq Run 41168: bottom ND3, Pt = 21.4%, I=100 nA, FR=2.4, SR=7.2
39239 08/26/01 22:19 cdaq Run 41167: bottom ND3, Pt = 22.3%, I=100 nA, FR=2.4, SR=7.2
39236 08/26/01 21:35 cdaq Run 41166: bottom ND3, Pt = 23.4%, I=100 nA, FR=2.4, SR=7.2
39232 08/26/01 20:33 cdaq Run 41164: bottom ND3, Pt = 23.7%, I=100 nA, FR=2.4, SR=7.2
39227 08/26/01 19:43 cdaq Run 41163: bottom ND3, Pt = 25.5%, I=100 nA, FR=2.4, SR=7.2
39226 08/26/01 19:35 cdaq Run 41162: bottom ND3, Pt = 30.5%, I=100 nA, FR=2.4, SR=7.2
39225 08/26/01 19:29 cdaq Run 41161: bottom ND3, Pt = 30.5%, I=100 nA, FR=2.4, SR=7.2
39223 08/26/01 19:03 cdaq Run 41160: bottom ND3, Pt = 30.5%, I=100 nA, FR=2.4, SR=7.2
39221 08/26/01 18:58 cdaq Run 41159: bottom ND3, Pt = 30.5%, I=100 nA, FR=2.4, SR=7.2
39184 08/26/01 08:02 cdaq Run 41147: Cosmics
39174 08/26/01 05:47 cdaq Run 41146: bottom ND3, Pt = 27.7%, I=100 nA, FR=2.4, SR=7.2
39171 08/26/01 04:52 cdaq Run 41145: bottom ND3, Pt = 29.9%, I=100 nA, FR=2.4, SR=7.2
39169 08/26/01 03:53 cdaq Run 41144: bottom ND3, Pt = 32.6%, I=100 nA, FR=2.4, SR=7.2
39166 08/26/01 03:28 cdaq Run 41143: bottom ND3, Pt = 32.5%, I=100 nA, FR=2.4, SR=7.2
39163 08/26/01 02:13 cdaq Run 41142: Carbon Target, Pt = 0, I=100 nA, FR=2.4, SR=7.2
39159 08/26/01 01:21 cdaq Run 41141: Carbon Target, Pt = 0, I=100 nA, FR=2.4, SR=7.2
39152 08/26/01 00:10 cdaq Run 41139: ND3 Top target, Pt = -19.9, I=100 nA, FR=2.4, SR=7.2
Saturday
39147 08/25/01 23:46 cdaq Run 41138: ND3 Top target, Pt = -20.1, I=100 nA, FR=2.4, SR=7.2
39145 08/25/01 22:53 cdaq Run 41137: ND3 Top target, Pt = -20.7, I=100 nA, FR=2.4, SR=7.2
39141 08/25/01 21:38 cdaq Run 41136: ND3 Top target, Pt = -22.3, I=100 nA, FR=2.4, SR=7.2
39137 08/25/01 20:46 cdaq Run 41135: ND3 Top target, Pt = -20.8%I=100 nA, FR=2.4, SR=7.2
39134 08/25/01 20:10 cdaq Run 41134: ND3 Top target, Pt = -21.0, I=100 nA, FR=2.4, SR=7.2
39125 08/25/01 19:06 cdaq Run 41133: ND3 Top target, Pt = -21.5, I=100 nA, FR=2.4, SR=7.2
39121 08/25/01 18:53 cdaq Run 41132: ND3 Top target, Pt = -21.5, I=100 nA, FR=2.4, SR=7.2
39118 08/25/01 18:27 cdaq Run 41131: ND3 Top target, Pt = -21.7, I=100 nA, FR=2.4, SR=7.2
39115 08/25/01 18:18 cdaq Run 41130: ND3 Top target, Pt = -21.7, I=100 nA, FR=2.4, SR=7.2
39112 08/25/01 17:26 cdaq Run 41129: ND3 Top target, Pt = -22.2, I=100 nA, FR=2.4, SR=7.2
39106 08/25/01 16:39 cdaq Run 41128: ND3 Top target, Pt = -22.2, I=100 nA, FR=2.4, SR=7.2
39100 08/25/01 15:48 cdaq Run 41127: ND3 Top target, Pt = -22.6, I=100 nA, FR=2.4, SR=7.2
39097 08/25/01 15:18 cdaq Run 41126: ND3 Top target, Pt = -23.0, I=100 nA, FR=2.4, SR=7.2
39089 08/25/01 14:18 cdaq Run 41125: ND3 Top target, Pt = -23.0, I=100 nA, FR=2.4, SR=7.2
39086 08/25/01 13:47 cdaq Run 41124: COSMIC, ND3 Top target, FR=2.4, SR=7.2
39083 08/25/01 13:24 cdaq Run 41123: ND3 Top target, Pt = -23.5, I=100 nA, FR=2.4, SR=7.2
39079 08/25/01 12:33 cdaq Run 41122: ND3 Top target, Pt = -23.5, I=100 nA, FR=2.4, SR=7.2
39075 08/25/01 11:40 cdaq Run 41121: ND3 Top target, Pt = -23.8, I=100 nA, FR=2.4, SR=7.2
39073 08/25/01 11:35 cdaq Run 41120: ND3 Top target, Pt = -23.9%, I=100 nA, FR=2.4, SR=7.2
39067 08/25/01 10:33 cdaq Run 41119: ND3 Top target, Pt = -24.5%, I=100 nA, FR=2.4, SR=7.2
39063 08/25/01 10:12 cdaq Run 41118: cosmics run while recovering from dipole trip
39061 08/25/01 09:45 cdaq Run 41117: ND3 Top target, Pt = -24.6%, I=100 nA, FR=2.4, SR=7.2
39057 08/25/01 08:52 cdaq Run 41116: ND3 Top target, Pt = -25.0%, I=100 nA, FR=2.4, SR=7.2
39054 08/25/01 08:04 cdaq Run 41115: ND3 Top target, Pt = -28.7%, I=100 nA, FR=2.4, SR=7.3
39047 08/25/01 07:15 cdaq Run 41114: ND3 Top target, Pt = -25.4%, I=100 nA, FR=2.4, SR=7.3
39044 08/25/01 06:20 cdaq Run 41113: ND3 Top target, Pt = -25.9%, I=100 nA, FR=2.4, SR=7.3
39038 08/25/01 05:29 cdaq Run 41112: ND3 Top target, Pt = -26.3%, I=100 nA, FR=2.4, SR=7.3
39032 08/25/01 04:47 cdaq Run 41111: ND3 Top target, Pt = -26.7%, I=100 nA, FR=2.4, SR=7.3
39028 08/25/01 04:19 cdaq Run 41110: ND3 Top target, Pt = -27.1%, I=100 nA, FR=2.4, SR=7.3
39023 08/25/01 03:31 cdaq Run 41109: ND3 Top target, Pt = -27.6%, I=100 nA, FR=2.4, SR=7.3
39015 08/25/01 02:01 cdaq Run 41108: ND3 Top target, Pt = -28.5%, I=100 nA, FR=2.4, SR=7.3
39012 08/25/01 01:22 cdaq Run 41107: ND3 Top target, Pt = -28.9%, I=100 nA, FR=2.4, SR=7.3
39008 08/25/01 00:30 cdaq Run 41106: ND3 Top target, Pt = -29.2%, I=100 nA, FR=2.4, SR=7.3
Friday
39001 08/24/01 23:39 cdaq Run 41105: ND3 Top target, Pt = -29.6%, I=100 nA, FR=2.4, SR=7.3
38997 08/24/01 22:47 cdaq Run 41103: ND3 Top target, Pt = -31.2%, I=100 nA, FR=2.4, SR=7.3
38994 08/24/01 21:51 cdaq Run 41102: ND3 Top target, Pt = -31.3%, I=100 nA, FR=2.4, SR=7.3
38989 08/24/01 21:30 cdaq Run 41101: ND3 Top target, Pt = -31.5%, I=100 nA, FR=2.4, SR=7.3
38987 08/24/01 21:09 cdaq Run 41100: ND3 Top target, Pt = -32.6%, I=100 nA, FR=2.4, SR=7.3
38983 08/24/01 20:26 cdaq Run 41099: ND3 Top target, Pt = -33.%, I=100 nA, FR=2.4, SR=7.3
38980 08/24/01 19:25 cdaq Run 41098: ND3 Top target, Pt = -33.2%, I=100 nA, FR=2.4, SR=7.3
38976 08/24/01 18:30 cdaq Run 41097: ND3 Top target, Pt = -33.5%, I=100 nA, FR=2.4, SR=7.3
38971 08/24/01 17:45 cdaq Run 41096: ND3 Top target, Pt = -34.1%, I=100 nA, FR=2.4, SR=7.3
38969 08/24/01 17:43 cdaq Run 41095: ND3 Top target, Pt = -36.1%, I=100 nA, FR=2.4, SR=7.3
38961 08/24/01 16:51 cdaq Run 41094: ND3 Top target, Pt = -36.1%, I=100 nA, FR=2.4, SR=7.3
38958 08/24/01 16:20 cdaq Run 41093: cosmic run; normal cosmic trigger
38955 08/24/01 16:13 cdaq Run 41092: cosmic run
38948 08/24/01 15:00 cdaq Run 41091: ND3 Top target, Pt = -36.4%, I=100 nA, FR=2.4, SR=7.3
38945 08/24/01 14:56 cdaq Run 41090: ND3 Top target, Pt = -36.3%, I=100 nA, FR=2.4, SR=7.3
38942 08/24/01 14:50 cdaq Run 41089: ND3 Top target, Pt = -37.4%, I=100 nA, FR=2.4, SR=7.3
38940 08/24/01 14:43 cdaq Run 41088: ND3 Top target, Pt = -38%, I=100 nA, FR=2.4, SR=7.3
38936 08/24/01 13:11 cdaq Run 41087: cosmics run
38913 08/24/01 09:36 cdaq Run 41081: cosmics run
38909 08/24/01 08:32 cdaq Run 41080: Empty target, I=200 nA, FR=2.4, SR=7.3
38904 08/24/01 07:45 cdaq Run 41078: Carbon target, I=200 nA, FR=2.4, SR=7.3
38902 08/24/01 07:22 cdaq Run 41077: Carbon run, I=100 nA, FR=2.4, SR=7.3
38897 08/24/01 06:14 cdaq Run 41075: Top ND3, P_t=-18.3, FR=2.4, SR=7.3
38895 08/24/01 06:11 cdaq Run 41074: Top ND3, P_t=-18.4, FR=2.4, SR=7.3
38890 08/24/01 05:33 cdaq Run 41073: Top ND3, P_t=-18.6, FR=2.4, SR=7.3
38888 08/24/01 04:42 cdaq Run 41072: Top ND3, P_t=-18.8, FR=2.4, SR=7.3
38886 08/24/01 03:48 cdaq Run 41071: Top ND3, P_t=-19.6, FR=2.4, SR=7.3
38880 08/24/01 02:53 cdaq Run 41070: Top ND3, P_t=-19.2, FR=2.4, SR=7.3
38877 08/24/01 02:05 cdaq Run 41069: Top ND3, P_t=-21.5, FR=2.4, SR=7.07
38868 08/24/01 00:33 cdaq Run 41068: Bottom ND3, P_t=-13.3, FR=2.4, SR=7.07
Thursday
38862 08/23/01 23:55 cdaq Run 41067: Bottom ND3, P_t=-14.3 FR=2.4, SR=7.3
38857 08/23/01 22:57 cdaq Run 41066: Bottom ND3, P_t=-14.0, FR=2.4, SR=7.3
38853 08/23/01 21:59 cdaq Run 41065: Bottom ND3, P_t=-15%, FR=2.4, SR=7.3
38850 08/23/01 21:15 cdaq Run 41064: Bottom ND3, P_t=-14.6, FR=2.4, SR=7.3
38847 08/23/01 20:25 cdaq Run 41063: Bottom ND3, P_t=-15.6, FR=2.4, SR=7.3
38844 08/23/01 19:32 cdaq Run 41062: Bottom ND3, P_t=-15.7, FR=2.4, SR=7.3
38838 08/23/01 18:51 cdaq Run 41061: Bottom ND3, P_t=-16.4, FR=2.4, SR=7.3
38834 08/23/01 18:01 cdaq Run 41060: Bottom ND3, P_t=-16.3, FR=2.4, SR=5.8
38827 08/23/01 17:07 cdaq Run 41059: Bottom ND3, P_t=-16.4, FR=2.4, SR=5.8
38822 08/23/01 16:10 cdaq Run 41056: Top ND3, P_t=-16, FR=2.4, SR=5.8
38813 08/23/01 13:55 cdaq Run 41055: Top ND3, P_t=+20.4, FR=2.4, SR=5.8
38809 08/23/01 12:55 cdaq Run 41054: Top ND3, P_t=+21.6%, FR=2.4, SR=5.8
38804 08/23/01 12:08 cdaq Run 41053: Top ND3, P_t=+22.1%, FR=2.4, SR=5.8
38800 08/23/01 11:14 cdaq Run 41052: Top ND3, P_t=+24.0%, FR=2.4, SR=5.8
38794 08/23/01 10:24 cdaq Run 41051: Top ND3, P_t=+23.2%, FR=2.4, SR=5.8
38790 08/23/01 09:49 cdaq Run 41050: Top ND3, P_t=+23.4%, FR=2.4, SR=5.8
38785 08/23/01 08:56 cdaq Run 41049: Top ND3, P_t=+24.1%, FR=2.4, SR=5.8
38779 08/23/01 07:55 cdaq Run 41048: Top ND3, P_t=+26.0%, FR=2.4, SR=5.8
38776 08/23/01 07:04 cdaq Run 41047: Top ND3, P_t=+26.0%, FR=2.4, SR=5.8
38773 08/23/01 06:14 cdaq Run 41046: Top ND3, P_t=+27.1%, FR=2.4, SR=5.8
38766 08/23/01 05:09 cdaq Run 41045: Top ND3, P_t=+28.3%, FR=2.4, SR=5.8
38763 08/23/01 04:14 cdaq Run 41044: Top ND3, P_t=+29.8%, FR=2.4, SR=5.8
38760 08/23/01 03:26 cdaq Run 41043: Top ND3, P_t=+32.3%, FR=2.4, SR=5.8
38757 08/23/01 02:36 cdaq Run 41042: Top ND3, P_t=+34.8%, FR=2.4, SR=5.8
38754 08/23/01 02:10 cdaq Run 41041: Top ND3, P_t=+34.5%, FR=2.4, SR=7.07
38743 08/23/01 00:20 cdaq Run 41040: Empty Target, FR=2.4, SR=7.07
Wednesday
38737 08/22/01 22:37 cdaq Run 41038: Top ND3, P_t=+20.2%, FR=2.4, SR=7.07
38730 08/22/01 21:09 cdaq Run 41037: Bottom ND3, P_t=+20.7% FR=2.4, SR=7.07
38727 08/22/01 20:25 cdaq Run 41036: Bottom ND3, P_t=+22.0%, FR=2.4, SR=7.07
38722 08/22/01 19:29 cdaq Run 41035: Bottom ND3, P_t=+24.0%, FR=2.4, SR=7.07
38717 08/22/01 18:48 cdaq Run 41030: Bottom ND3, P_t=+24.1%, FR=2.4, SR=7.07
38702 08/22/01 15:26 cdaq Run 41029: COSMIC, FR=2.4, SR=7.07
38700 08/22/01 15:01 cdaq Run 41028: COSMIC, FR=2.4, SR=7.07
38695 08/22/01 14:06 cdaq Run 41027: Top ND3, P_t=-21.5%, FR=2.4, SR=7.07
38687 08/22/01 13:22 cdaq Run 41026: Top ND3, P_t=-22.3%, FR=2.4, SR=7.07
38682 08/22/01 12:25 cdaq Run 41025: Top ND3, P_t=-22.1%, FR=2.4, SR=7.29
38680 08/22/01 12:21 cdaq Run 41024: Top ND3, P_t=-22.1%, FR=2.4, SR=7.29
38677 08/22/01 11:28 cdaq Run 41023: Top ND3, P_t=-22.9%, FR=2.4, SR=7.07
38674 08/22/01 10:43 cdaq Run 41022: Top ND3, P_t=-26.0%, FR=2.4, SR=7.07
38670 08/22/01 09:45 cdaq Run 41021: Top ND3, P_t=-24.4%, FR=2.4, SR=7.07
38665 08/22/01 08:57 cdaq Run 41020: Top ND3, P_t=-24.8%, FR=2.4, SR=7.07
38657 08/22/01 08:06 cdaq Run 41019: Top ND3, P_t=-24.3%, FR=2.4, SR=7.07
38655 08/22/01 07:27 cdaq Run 41018: Top ND3, P_t=-25.1%, FR=2.4, SR=7.07
38652 08/22/01 06:28 cdaq Run 41017: ND3 top target, P_t=-24.4%, FR=2.4, SR=7.07
38648 08/22/01 05:35 cdaq Run 41016: Top ND3, P_t=-25.2%, FR=2.4, SR=7.07
38646 08/22/01 05:00 cdaq Run 41015: ND3 top target, P_t=-25.6%, FR=2.4, SR=7.07
38642 08/22/01 04:00 cdaq Run 41014: ND3 top target, P_t=-25.1%, FR=2,4, SR=7.07
38637 08/22/01 03:06 cdaq Run 41013: ND3 top target, P_t=-25.0%,FR=2,4, SR=7.07
38634 08/22/01 02:35 cdaq Run 41012: data run with beam back.
38629 08/22/01 01:44 cdaq Run 41011: data run with beam back.
38624 08/22/01 00:48 cdaq Run 41010: data run with beam back.
Tuesday
38615 08/21/01 23:11 cdaq Run 41006: data run with beam back.
38611 08/21/01 22:19 cdaq Run 41005: data run with beam back.
38607 08/21/01 21:21 cdaq Run 41004: first data run with beam back.
38601 08/21/01 18:56 cdaq Run 41003: cosmic test
38590 08/21/01 09:13 cdaq Run 41002: Cosmics run
38587 08/21/01 09:00 cdaq Run 41001: ND3 bottom Target, P_t=+15.5, FR=2.4A, SR=7.2
38585 08/21/01 08:38 cdaq Run 41000: ND3 bottom Target, P_t=+14.2, FR=2.4A, SR=7.2
38581 08/21/01 08:03 cdaq Run 40998: ND3 bottom Target, P_t=+16.8, FR=2.4A, SR=7.2
38577 08/21/01 07:11 cdaq Run 40997: ND3 bottom Target, P_t=+17.3, FR=2.4A, SR=7.2
38574 08/21/01 06:36 cdaq Run 40996: ND3 bottom Target, P_t=+17.2, FR=2.4A, SR=7.2
38571 08/21/01 05:42 cdaq Run 40995: ND3 bottom Target, P_t=+23.0, FR=2.4A, SR=7.2
38569 08/21/01 05:19 cdaq Run 40994: ND3 bottom Target, P_t=+20.8, FR=2.4A, SR=7.2
38563 08/21/01 04:03 cdaq Run 40993: ND3 bottom Target, P_t=+19.8, FR=2.4A, SR=7.2
38560 08/21/01 03:21 cdaq Run 40992: ND3 bottom Target, P_t=+19.8, FR=2.4A, SR=7.2
38556 08/21/01 02:31 cdaq Run 40991: ND3 bottom Target, P_t=+19.4, FR=2.4A, SR=7.2
38551 08/21/01 01:41 cdaq Run 40990: ND3 bottom Target, P_t=+22.1, FR=2.4A, SR=7.2
Monday
38541 08/20/01 21:29 cdaq Run 40989: ND3 Top Target, P_t=-23.1, FR=2.4A, SR=7.2
38538 08/20/01 20:38 cdaq Run 40988: ND3 Top Target, P_t=-23.1, FR=2.4A, SR=7.2
38533 08/20/01 19:42 cdaq Run 40987: ND3 Top Target, P_t=-23.1, FR=2.4A, SR=7.2
38529 08/20/01 19:00 cdaq Run 40986: ND3 Top Target, P_t=-24.8, FR=2.4A, SR=7.6
38525 08/20/01 18:08 cdaq Run 40985: ND3 Top Target, P_t=-24.6, FR=2.4A, SR=7.6
38521 08/20/01 17:18 cdaq Run 40984: ND3 Top Target, P_t=-24.6, FR=2.4A, SR=7.6
38519 08/20/01 17:00 cdaq Run 40983: ND3 Top Target, P_t=-23.9, FR=2.4A, SR=7.6
38516 08/20/01 16:09 cdaq Run 40982: ND3 Top Target, P_t=-27.9, FR=2.4A, SR=7.6
38512 08/20/01 15:41 cdaq Run 40981: ND3 Top Target, P_t=-26.9, FR=2.4A, SR=7.6
38509 08/20/01 14:44 cdaq Run 40980: ND3 Top Target, P_t=-26.8, FR=2.4A, SR=7.6
38507 08/20/01 14:15 cdaq Run 40979: ND3 Top Target, P_t=-26.4, FR=2.4A, SR=7.6
38503 08/20/01 13:47 cdaq Run 40978: ND3 Top Target, P_t=-26.3, FR=2.4A, SR=7.6
38500 08/20/01 13:13 cdaq Run 40977: ND3 Top Target, P_t=-27.2, FR=2.4A, SR=7.6
38496 08/20/01 12:37 cdaq Run 40976: ND3 Top Target, P_t=-27.2, FR=2.4A, SR=7.6
38493 08/20/01 12:07 cdaq Run 40975: ND3 Top Target, P_t=-25.6,
38480 08/20/01 09:39 cdaq Run 40974: Cosmics run
38474 08/20/01 07:49 cdaq Run 40973: ND3 top, SR=5.8A FR=2.4A P_t=-31.2%
38470 08/20/01 05:26 cdaq Run 40972: ND3 top, SR=5.8A FR=2.4A P_t=-25.4%
38468 08/20/01 05:11 cdaq Run 40971: ND3 top, SR=5.8A FR=2.4A P_t=-25.4%
38465 08/20/01 04:44 cdaq Run 40970: ND3 top, SR=5.8A FR=2.4A P_t=-25.4%
38463 08/20/01 04:19 cdaq Run 40969: ND3 top, SR=5.8A FR=2.4A P_t=-25.4%
Sunday
38453 08/19/01 22:29 cdaq Run 40968: ND3 top, SR=5.8A FR=2.4A P_t=-25.4%
38448 08/19/01 21:54 cdaq Run 40967: ND3 top, SR=5.8A FR=2.4A P_t=-25.4%
38428 08/19/01 16:05 cdaq Run 40954: ND3 top, SR=5.8A FR=2.4A P_t=-21.0%
38423 08/19/01 15:49 cdaq Run 40953: ND3 top, SR=5.8A FR=2.4A P_t=-21.0%
38420 08/19/01 15:13 cdaq Run 40952: ND3 top, SR=5.8A FR=2.4A P_t=-21.5%
38416 08/19/01 14:47 cdaq Run 40951: ND3 top, SR=5.8A FR=2.4A P_t=-22.1%
38413 08/19/01 14:12 cdaq Run 40950: ND3 top, SR=5.8A FR=2.4A P_t=-23.8%
38410 08/19/01 13:38 cdaq Run 40949: ND3 top, SR=5.8A FR=2.4A P_t=-22.5%
38406 08/19/01 12:44 cdaq Run 40948: ND3 top, SR=5.8A FR=2.4A P_t=-25.4%
38405 08/19/01 12:08 cdaq Run 40947: ND3 top, SR=5.8A FR=2.4A P_t=-23.6%
38401 08/19/01 11:51 cdaq Run 40946: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38399 08/19/01 11:23 cdaq Run 40945: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38396 08/19/01 10:29 cdaq Run 40944: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38390 08/19/01 08:05 cdaq Run 40943: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38386 08/19/01 07:33 cdaq Run 40942: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38384 08/19/01 07:04 cdaq Run 40941: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38381 08/19/01 06:34 cdaq Run 40940: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38379 08/19/01 06:19 cdaq Run 40939: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38376 08/19/01 05:53 cdaq Run 40938: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38374 08/19/01 05:17 cdaq Run 40937: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38371 08/19/01 04:49 cdaq Run 40936: ND3 top, SR=5.8A FR=2.4A launch angle=-20.6
38367 08/19/01 03:33 cdaq Run 40935: ND3 bottom, SR=5.8A FR=2.4A launch angle=-20.6
38364 08/19/01 02:47 cdaq Run 40934: ND3 bottom, SR=5.8A FR=2.4A launch angle=-20.6
38361 08/19/01 02:26 cdaq Run 40933: ND3 bottom, SR=5.72A FR=2.4A launch angle=-20.6
38359 08/19/01 01:59 cdaq Run 40932: bottom, SR=5.8A FR=2.4A launch angle=-20.6
38357 08/19/01 01:30 cdaq Run 40931: bottom, SR=5.8A FR=2.4A launch angle=-20.6
38355 08/19/01 01:03 cdaq Run 40930: bottom, SR=5.8A FR=2.4A launch angle=-20.6
38352 08/19/01 00:38 cdaq Run 40929: bottom, SR=5.8A FR=2.4A launch angle=-22.98
38349 08/19/01 00:09 cdaq Run 40928: bottom, SR=5.7A FR=2.4A launch angle=-22.98
Saturday
38345 08/18/01 23:37 cdaq Run 40927: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38343 08/18/01 23:07 cdaq Run 40926: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38340 08/18/01 22:41 cdaq Run 40925: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38338 08/18/01 22:16 cdaq Run 40924: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38335 08/18/01 21:51 cdaq Run 40923: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38333 08/18/01 21:08 cdaq Run 40922: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38328 08/18/01 19:04 cdaq Run 40921: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38324 08/18/01 18:34 cdaq Run 40920: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38322 08/18/01 18:07 cdaq Run 40919: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38319 08/18/01 17:40 cdaq Run 40918: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38317 08/18/01 17:23 cdaq Run 40917: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38314 08/18/01 16:55 cdaq Run 40916: bottom, SR=5.7A FR=2.4A launch angle=-22.98
38289 08/18/01 11:05 cdaq Run 40903: empty, sr=7.53A FR=2.4A launch angle=-22.98
38287 08/18/01 10:37 cdaq Run 40902: empty, sr=7.53A FR=2.4A launch angle=-22.98
38285 08/18/01 10:06 cdaq Run 40901: carbon, sr=7.53A FR=2.4A launch angle=-22.98
38282 08/18/01 09:46 cdaq Run 40900: carbon, sr=7.53A FR=2.4A launch angle=-22.98
38280 08/18/01 09:31 cdaq Run 40899: carbon, sr=7.53A FR=2.4A launch angle=-22.98
38276 08/18/01 09:11 cdaq Run 40898: carbon, sr=7.53A FR=2.4A launch angle=-22.98
38273 08/18/01 08:09 cdaq Run 40897: ND3 top, pol=28.2, sr=7.53A FR=2.4A launch angle=-22.98
38268 08/18/01 07:45 cdaq Run 40896: ND3 top, pol=31.1, sr=7.53A FR=2.4A launch angle=-22.98
38266 08/18/01 07:21 cdaq Run 40895: ND3 top, pol=27.8, sr=7.53A FR=2.4A launch angle=-22.98
38264 08/18/01 07:01 cdaq Run 40894: ND3 top, pol=26.9, sr=7.53A FR=2.4A launch angle=-22.98
38261 08/18/01 06:41 cdaq Run 40893: ND3 top, pol=27.4, sr=7.53A FR=2.4A launch angle=-22.98
38259 08/18/01 06:32 cdaq Run 40892: ND3 top, pol=27.4, sr=7.53A FR=2.4A launch angle=-22.98
38257 08/18/01 06:09 cdaq Run 40891: ND3 top, pol=31.3, sr=7.53A FR=2.4A launch angle=-22.98
38253 08/18/01 04:32 cdaq Run 40890: ND3 top, pol=26.4, sr=7.43A FR=2.4A launch angle=-22.98
38251 08/18/01 04:17 cdaq Run 40889: ND3 top, pol=32.4, sr=7.53A FR=2.4A launch angle=-22.98
38248 08/18/01 03:49 cdaq Run 40888: ND3 top, pol=32.4, sr=7.53A FR=2.4A launch angle=-22.98
38246 08/18/01 03:23 cdaq Run 40887: ND3 top, pol=28.9, sr=7.4A FR=2.4A launch angle=-22.98
38243 08/18/01 02:48 cdaq Run 40886: ND3 top, pol=28.9, sr=7.4A FR=2.4A launch angle=-22.98
38241 08/18/01 02:33 cdaq Run 40885: ND3 top, pol=28.9, sr=7.53A FR=2.4A launch angle=-22.98
38239 08/18/01 02:06 cdaq Run 40884: ND3 top, pol=28.9, sr=7.53A FR=2.4A launch angle=-22.98
38236 08/18/01 01:40 cdaq Run 40883: ND3 top, pol=29.7, sr=7.4A FR=2.4A launch angle=-22.98
38232 08/18/01 00:21 cdaq Run 40882: ND3 top, pol=35.0, sr=7.4A FR=2.4A launch angle=-22.98
Friday
38226 08/17/01 23:48 cdaq Run 40881: ND3 top, pol=32.0, sr=7.4A FR=2.4A launch angle=-22.98
38224 08/17/01 23:33 cdaq Run 40880: ND3 top, pol=29.9, sr=7.4A FR=2.4A launch angle=-22.98
38222 08/17/01 23:18 cdaq Run 40879: ND3 top, pol=30.9, sr=7.4A FR=2.4A launch angle=-22.98
38220 08/17/01 22:52 cdaq Run 40878: ND3 top, pol=30.8, sr=7.4A FR=2.4A launch angle=-22.98
38218 08/17/01 22:23 cdaq Run 40877: ND3 top, pol=28.8 sr=7.4A FR=2.4A launch angle=-22.98
38216 08/17/01 21:57 cdaq Run 40876: ND3 top, pol=30.3, sr=7.4A FR=2.4A launch angle=-22.98
38214 08/17/01 21:24 cdaq Run 40875: ND3 top, pol=30.2, sr=7.4A FR=2.4A launch angle=-22.98
38212 08/17/01 20:57 cdaq Run 40874: ND3 top, pol=31.0, sr=7.4A FR=2.4A launch angle=-22.98
38210 08/17/01 20:40 cdaq Run 40873: ND3 top, pol=31.5, sr=7.4A FR=2.4A launch angle=-22.98
38208 08/17/01 20:13 cdaq Run 40872: ND3 top, pol=31.7, sr=7.4A FR=2.4A launch angle=-22.98
38206 08/17/01 19:47 cdaq Run 40871: ND3 top, pol=33.0, sr=7.4A FR=2.4A launch angle=-22.98
38201 08/17/01 19:19 cdaq Run 40870: ND3 top, pol=32.0 sr=7.4A FR=2.4A launch angle=-22.98
38199 08/17/01 18:48 cdaq Run 40869: ND3 top, pol=31.6, sr=7.4A FR=2.4A launch angle=-22.98
38197 08/17/01 18:22 cdaq Run 40868: ND3 top, pol=30.3, sr=7.4A FR=2.4A launch angle=-22.98
38170 08/17/01 08:22 cdaq Run 40864: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38164 08/17/01 07:55 cdaq Run 40863: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38162 08/17/01 07:28 cdaq Run 40862: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38159 08/17/01 07:02 cdaq Run 40861: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38156 08/17/01 06:29 cdaq Run 40860: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38152 08/17/01 06:18 cdaq Run 40859: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38151 08/17/01 05:37 cdaq Run 40858: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38148 08/17/01 05:15 cdaq Run 40857: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38145 08/17/01 04:46 cdaq Run 40856: ND3 top, pol=37.9, sr=7.6A FR=2.4A launch angle=-23.99
38141 08/17/01 04:09 cdaq Run 40855: ND3 top, pol=39.7, sr=7.6A FR=2.4A launch angle=-23.99
38139 08/17/01 03:38 cdaq Run 40854: ND3 top, pol=40.0, sr=7.6A FR=2.4A launch angle=-23.99
38136 08/17/01 03:04 cdaq Run 40853: ND3 top, pol=45.2, sr=7.6A FR=2.4A launch angle=-23.99
38132 08/17/01 01:52 cdaq Run 40852: ND3 top, pol=39.8, sr=7.6A FR=2.4A launch angle=-23.99
38130 08/17/01 01:19 cdaq Run 40851: ND3 top, pol=40.3, sr=7.6A FR=2.4A launch angle=-23.99
38127 08/17/01 00:36 cdaq Run 40850: ND3 top, pol=40.8, sr=7.6A FR=2.4A launch angle=-23.99
38123 08/17/01 00:07 cdaq Run 40849: Top ND3 sr=7.6A FR=2.4A launch angle=-23.99
Thursday
38116 08/16/01 19:43 cdaq Run 40848: Top ND3 sr=7.6A FR=2.4A launch angle=-23.99
38114 08/16/01 18:59 cdaq Run 40847: empty target sr=7.6A FR=2.4A launch angle=-23.99
38112 08/16/01 18:37 cdaq Run 40846: empty target sr=7.6A FR=2.4A launch angle=-23.99
38109 08/16/01 17:36 cdaq Run 40845: empty target sr=7.6A FR=2.4A launch angle=-23.99
38106 08/16/01 17:06 cdaq Run 40844: carbon sr=7.6A FR=2.4A launch angle=-23.99
38104 08/16/01 16:44 cdaq Run 40843: carbon sr=7.6A FR=2.4A launch angle=-23.99
38095 08/16/01 12:45 cdaq Run 40840: SEM static mode calibration: 4 mA
38094 08/16/01 12:38 cdaq Run 40839: SEM static mode calibration: 20 mA
38093 08/16/01 12:03 cdaq Run 40838: pulser run SR=1.00cm I=6.59Amp
Wednesday
38084 08/15/01 19:04 cdaq Run 40837: Cosmics for neutron detector
38083 08/15/01 18:50 cdaq Run 40836: Cosmics for neutron detector
38082 08/15/01 18:37 cdaq Run 40835: Cosmics for neutron detector
38081 08/15/01 18:24 cdaq Run 40834: Cosmics for neutron detector
38080 08/15/01 18:08 cdaq Run 40833: Cosmics for neutron detector
38079 08/15/01 17:44 cdaq Run 40832: Cosmics for neutron detector
38077 08/15/01 15:56 cdaq Run 40831: Cosmics for neutron detector
38075 08/15/01 15:20 cdaq Run 40830: Cosmics for neutron detector
38074 08/15/01 14:45 cdaq Run 40829: Cosmics for neutron detector
38073 08/15/01 11:47 cdaq Run 40828: Neutron detector TDC test
38072 08/15/01 10:20 cdaq Run 40827: Cosmics for neutron detector, TDC checkout
Tuesday
38065 08/14/01 16:43 cdaq Run 40826: Cosmics for neutron detector, TDC check
38064 08/14/01 15:29 cdaq Run 40825: Cosmics run. swapped K + L outputs of delay.
38063 08/14/01 15:10 cdaq Run 40824: test run for raster
38062 08/14/01 15:04 cdaq Run 40823: test run for raster
38059 08/14/01 14:52 cdaq Run 40822: raster test run
38058 08/14/01 14:30 cdaq Run 40820: Cosmics for neutron detector new nominal HV
38057 08/14/01 13:53 cdaq Run 40819: Cosmics for neutron detector new nominal HV
38055 08/14/01 09:44 cdaq Run 40818: Cosmics for neutron detector new nominal HV
Monday
38049 08/13/01 18:17 cdaq Run 40817: Cosmics for neutron detector new nominal HV
38048 08/13/01 17:55 cdaq Run 40816: pulser run for SEM 1Hz
38047 08/13/01 17:51 cdaq Run 40815: pulser run for SEM
38046 08/13/01 16:30 cdaq Run 40814: Cosmics for neutron detector - low HV setting.
38044 08/13/01 15:55 cdaq Run 40813: Cosmics for neutron detector - low HV setting.
38043 08/13/01 14:58 cdaq Run 40812: Cosmics for neutron detector - new nominal decremented
38042 08/13/01 13:37 cdaq Run 40811: Cosmics for neutron detector - new nominal values
38041 08/13/01 12:16 cdaq Run 40810: Cosmics for neutron detector with increased HV
38039 08/13/01 11:17 cdaq Run 40809: cosmics run for neutron detector; low ndet HV
38038 08/13/01 10:30 cdaq Run 40808: cosmics run for neutron detector
38037 08/13/01 09:57 cdaq Run 40807: pulser run for 15Hz slow raster test
38036 08/13/01 08:58 cdaq Run 40806: Cosmics for neutron detector. Bar thr=15mv
38035 08/13/01 08:37 cdaq Run 40805: Cosmics for neutron detector
38031 08/13/01 03:53 cdaq Run 40804: SEM = STATIC, ND3 bottom, THRESHOLD 25mV
38029 08/13/01 03:25 cdaq Run 40803: SEM = STATIC, ND3 bottom, THRESHOLD 25mV
38027 08/13/01 02:58 cdaq Run 40802: SEM = STATIC, ND3 bottom, THRESHOLD 25mV
38025 08/13/01 02:34 cdaq Run 40801: SEM = STATIC, ND3 bottom, THRESHOLD 25mV
38021 08/13/01 02:06 cdaq Run 40800: SEM = STATIC, 12C , THRESHOLD 25mV
38019 08/13/01 01:12 cdaq Run 40799: Cosmic run
Sunday
37992 08/12/01 07:15 cdaq Run 40791: SEM = STATIC, 12C , THRESHOLD 25mV
37991 08/12/01 06:48 cdaq Run 40790: SEM = STATIC, 12C , THRESHOLD 25mV
37990 08/12/01 06:25 cdaq Run 40789: SEM = STATIC, 12C , THRESHOLD 25mV
37989 08/12/01 06:02 cdaq Run 40788: SEM = STATIC, 12C , THRESHOLD 25mV
37988 08/12/01 05:39 cdaq Run 40787: SEM = STATIC, 12C , THRESHOLD 25mV
37987 08/12/01 05:15 cdaq Run 40786: SEM = STATIC, 12C , THRESHOLD 25mV
37986 08/12/01 04:51 cdaq Run 40785: SEM = STATIC, 12C , THRESHOLD 25mV
37983 08/12/01 04:18 cdaq Run 40784: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37982 08/12/01 03:53 cdaq Run 40783: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37980 08/12/01 03:29 cdaq Run 40782: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37979 08/12/01 03:02 cdaq Run 40781: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37978 08/12/01 02:37 cdaq Run 40780: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37977 08/12/01 02:11 cdaq Run 40779: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37974 08/12/01 01:45 cdaq Run 40778: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37973 08/12/01 01:30 cdaq Run 40777: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37972 08/12/01 01:04 cdaq Run 40776: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37969 08/12/01 00:39 cdaq Run 40775: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37968 08/12/01 00:12 cdaq Run 40774: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
Saturday
37963 08/11/01 23:46 cdaq Run 40773: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37962 08/11/01 23:32 cdaq Run 40772: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37961 08/11/01 23:08 cdaq Run 40771: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37960 08/11/01 22:42 cdaq Run 40770: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37959 08/11/01 22:16 cdaq Run 40769: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37958 08/11/01 22:12 cdaq Run 40768: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37956 08/11/01 21:46 cdaq Run 40767: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37955 08/11/01 21:20 cdaq Run 40766: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37953 08/11/01 20:53 cdaq Run 40765: SEM = STATIC, ND3 BOTTOM, THRESHOLD 25mV
37952 08/11/01 20:25 cdaq Run 40764: SEM = 115, ND3 BOTTOM, THRESHOLD 25mV
37951 08/11/01 20:04 cdaq Run 40763: SEM = EVENT MODE, ND3 BOTTOM, THRESHOLD 25mV
37949 08/11/01 19:33 cdaq Run 40762: ND3 bottom, Pol=-31.4, threshold=25 mv
37937 08/11/01 14:11 cdaq Run 40761: ND3 bottom, Pol=-29.7, threshold=25 mv
37935 08/11/01 13:47 cdaq Run 40760: ND3 bottom, Pol=-30.5, threshold=25 mv
37934 08/11/01 13:32 cdaq Run 40759: ND3 bottom, Pol=-31.4, threshold=25 mv
37933 08/11/01 13:03 cdaq Run 40758: ND3 bottom, Pol=-31.6, threshold=25 mv
37932 08/11/01 12:37 cdaq Run 40757: ND3 bottom, Pol=-32.3, threshold=25 mv
37930 08/11/01 12:07 cdaq Run 40756: ND3 bottom, Pol=-30.8, threshold=25 mv
37929 08/11/01 11:43 cdaq Run 40755: ND3 bottom, Pol=-29.4, threshold=25 mv
37928 08/11/01 11:40 cdaq Run 40754: ND3 bottom, Pol=-29.4, threshold=25 mv
37926 08/11/01 11:14 cdaq Run 40753: ND3 bottom, Pol=-24.9, threshold=25 mv
37925 08/11/01 11:12 cdaq Run 40752: ND3 bottom, Pol=-24.1, threshold=25 mv
37924 08/11/01 10:57 cdaq Run 40751: ND3 bottom, Pol=-19.9, threshold=25 mv
37922 08/11/01 10:31 cdaq Run 40750: ND3 bottom, Pol=-10.8, threshold=25 mv
37921 08/11/01 10:06 cdaq Run 40749: ND3 bottom, Pol=-2.4, threshold=25 mv
37920 08/11/01 08:05 cdaq Run 40748: 12C , bar threshold=25 mv
37917 08/11/01 07:42 cdaq Run 40747: 12C , bar threshold=25 mv
37916 08/11/01 07:18 cdaq Run 40746: 12C , bar threshold=25 mv
37915 08/11/01 07:03 cdaq Run 40745: 12C , bar threshold=25 mv
37913 08/11/01 06:40 cdaq Run 40744: 12C Top, bar threshold=25 mv
37912 08/11/01 06:07 cdaq Run 40743: ND3 Top, bar threshold=25 mv
37911 08/11/01 05:42 cdaq Run 40742: ND3 Top, bar threshold=25 mv
37910 08/11/01 05:16 cdaq Run 40741: ND3 Top, bar threshold=25 mv
37908 08/11/01 04:48 cdaq Run 40740: ND3 Top, bar threshold=25 mv
37907 08/11/01 04:30 cdaq Run 40739: ND3 Top, bar threshold=25 mv
37906 08/11/01 04:04 cdaq Run 40738: ND3 Top, bar threshold=25 mv
37904 08/11/01 03:39 cdaq Run 40737: ND3 Top, bar threshold=25 mv
37902 08/11/01 03:13 cdaq Run 40736: ND3 Top, bar threshold=25 mv
37901 08/11/01 02:45 cdaq Run 40735: ND3 Top, bar threshold=25 mv
37900 08/11/01 02:12 cdaq Run 40734: ND3 Top, bar threshold=25 mv
37898 08/11/01 01:43 cdaq Run 40733: ND3 Top, bar threshold=25 mv
37897 08/11/01 01:08 cdaq Run 40732: ND3 Top, bar threshold=25 mv
37894 08/11/01 00:35 cdaq Run 40731: ND3 Top, bar threshold=25 mv
37891 08/11/01 00:06 cdaq Run 40730: ND3 Top
Friday
37889 08/10/01 23:35 cdaq Run 40729: ND3 Top
37888 08/10/01 23:11 cdaq Run 40728: ND3 Top
37886 08/10/01 22:42 cdaq Run 40727: ND3 Top
37885 08/10/01 22:14 cdaq Run 40726: ND3 Top
37883 08/10/01 21:46 cdaq Run 40725: ND3 Top
37882 08/10/01 21:11 cdaq Run 40724: ND3 Top
37880 08/10/01 20:39 cdaq Run 40723: ND3 Top
37879 08/10/01 20:10 cdaq Run 40722: ND3 Top
37877 08/10/01 19:39 cdaq Run 40721: ND3 Top
37875 08/10/01 17:42 cdaq Run 40720: Cosmics Run
37867 08/10/01 15:03 cdaq Run 40719: ND3 top, Pol=-21.7, BAR thresh = 25mV, STATIC, 80 nano amps
37866 08/10/01 14:53 cdaq Run 40718: ND3 top, Pol=-21.7, BAR thresh = 25mV, STATIC, 80 nano amps
37864 08/10/01 14:17 cdaq Run 40717: ND3 top, Pol=-21.7, BAR thresh = 25mV, STATIC, 80 nano amps
37863 08/10/01 13:44 cdaq Run 40716: ND3 top, Pol=-21.7, BAR thresh = 25mV, STATIC, 80 nano amps
37861 08/10/01 13:09 cdaq Run 40715: ND3 top, Pol=-21.7, BAR thresh = 25mV, STATIC, 80 nano amps
37859 08/10/01 12:53 cdaq Run 40714: ND3 top, Pol=-21.7, BAR thresh = 25mV, STATIC, 80 nano amps
37858 08/10/01 12:47 cdaq Run 40713: ND3 top, Pol=17, BAR thresh = 25mV, STATIC, 80 nano amps
37856 08/10/01 12:13 cdaq Run 40712: ND3 top, Pol=-21, BAR thresh = 25mV, STATIC, 80 nano amps
37853 08/10/01 11:38 cdaq Run 40711: ND3 top, Pol=-20.8, BAR thresh = 25mV, STATIC, 80 nano amps
37851 08/10/01 11:15 cdaq Run 40710: ND3 top, Pol=-20.8, BAR thresh = 25mV, STATIC, 80 nano amps
37849 08/10/01 10:21 cdaq Run 40709: ND3 top, Pol=-20.8, BAR thresh = 25mV, STATIC, 80 nano amps
37847 08/10/01 09:16 cdaq Run 40708: ND3 top, Pol=-19.5, BAR thresh = 25mV, STATIC, 80 nano amps
37845 08/10/01 08:43 cdaq Run 40707: ND3 top, Pol=-19.2, BAR thresh = 25mV, STATIC, 80 nano amps
37843 08/10/01 08:04 cdaq Run 40706: ND3 top, Pol=17, BAR thresh = 25mV, STATIC, 80 nano amps
37839 08/10/01 07:34 cdaq Run 40705: ND3 top, Pol=15, BAR thresh = 25mV, STATIC, 80 nano amps
37834 08/10/01 05:32 cdaq Run 40704: carbon, BAR thresh = 25mV, STATIC
37832 08/10/01 05:08 cdaq Run 40703: carbon, BAR thresh = 25mV, STATIC
37831 08/10/01 04:31 cdaq Run 40702: ND3 bottom, Pol=18.6, BAR thresh = 25mV, STATIC
37830 08/10/01 04:02 cdaq Run 40701: ND3 bottom, Pol=18.6, BAR thresh = 25mV, STATIC
37828 08/10/01 03:38 cdaq Run 40700: ND3 bottom, Pol=19.1, BAR thresh = 25mV, STATIC
37827 08/10/01 03:24 cdaq Run 40699: ND3 bottom, Pol=19.8, BAR thresh = 25mV, STATIC
37825 08/10/01 02:56 cdaq Run 40698: ND3 bottom, Pol=18.5, BAR thresh = 25mV, STATIC
37824 08/10/01 02:30 cdaq Run 40697: ND3 bottom, Pol=19.3, BAR thresh = 25mV, STATIC
37823 08/10/01 02:07 cdaq Run 40696: ND3 bottom, Pol=19.0, BAR thresh = 25mV, STATIC
37821 08/10/01 01:37 cdaq Run 40695: ND3 bottom, Pol=20.3, BAR thresh = 25mV, STATIC
37820 08/10/01 01:11 cdaq Run 40694: ND3 bottom, Pol=20.2, BAR thresh = 25mV, STATIC
37818 08/10/01 00:55 cdaq Run 40693: ND3 bottom, Pol=20.5, BAR thresh = 25mV, STATIC
37817 08/10/01 00:24 cdaq Run 40692: ND3 bottom, Pol=19.7, BAR thresh = 25mV, STATIC
37816 08/10/01 00:14 cdaq Run 40691: ND3 bottom, Pol=21.0, BAR thresh = 25mV, EVENT
Thursday
37812 08/09/01 23:45 cdaq Run 40690: ND3 bottom, Pol=21.0, BAR thresh = 25mV, STATIC
37811 08/09/01 23:19 cdaq Run 40689: ND3 bottom, Pol=18.9, BAR thresh = 25mV, STATIC
37810 08/09/01 23:16 cdaq Run 40688: ND3 bottom, Pol=18.9, BAR thresh = 25mV, STATIC
37809 08/09/01 23:09 cdaq Run 40687: ND3 bottom, Pol=17.0, BAR thresh = 25mV, STATIC
37807 08/09/01 22:38 cdaq Run 40686: ND3 bottom, Pol=17.0, BAR thresh = 25mV, STATIC
37805 08/09/01 22:10 cdaq Run 40685: ND3 bottom, Pol=+14.2, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37804 08/09/01 21:44 cdaq Run 40684: ND3 bottom, Pol=+13.2, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37803 08/09/01 21:15 cdaq Run 40683: ND3 bottom, Pol=+10.4, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37789 08/09/01 17:54 cdaq Run 40672: ND3 top, Pol=+19.4, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37788 08/09/01 17:30 cdaq Run 40671: ND3 top, Pol=+18.5, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37787 08/09/01 17:05 cdaq Run 40670: ND3 top, Pol=+18.5, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37785 08/09/01 16:41 cdaq Run 40669: ND3 top, Pol=+19.1, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37784 08/09/01 16:14 cdaq Run 40668: ND3 top, Pol=+19.2, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37780 08/09/01 15:43 cdaq Run 40667: ND3 top, Pol=+19.6, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37778 08/09/01 15:15 cdaq Run 40666: ND3 top, Pol=+19.7, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37776 08/09/01 14:46 cdaq Run 40665: ND3 top, Pol=+20.2, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37775 08/09/01 14:17 cdaq Run 40664: ND3 top, Pol=+22.6, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37771 08/09/01 13:43 cdaq Run 40663: ND3 top, Pol=+20.3, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37770 08/09/01 13:13 cdaq Run 40662: ND3 top, Pol=+19.7, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37767 08/09/01 12:56 cdaq Run 40661: ND3 top, Pol=+19.4, BAR thresh = 25mV, 1/2 WAVE PLATE OUT, STATIC
37765 08/09/01 12:11 cdaq Run 40660: ND3 top Pol=+20.0 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37760 08/09/01 11:38 cdaq Run 40659: ND3 bottom Pol=-18.9 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 EVENT
37758 08/09/01 11:04 cdaq Run 40658: ND3 top Pol=+15.9 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37756 08/09/01 10:38 cdaq Run 40657: ND3 top Pol=+14.1 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37751 08/09/01 08:14 cdaq Run 40656: Carbon target, BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37747 08/09/01 08:01 cdaq Run 40655: Carbon target, BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37745 08/09/01 07:36 cdaq Run 40654: Carbon target, BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 EVENT
37742 08/09/01 06:34 cdaq Run 40653: ND3 bottom Pol=-18.9 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 EVENT
37740 08/09/01 06:08 cdaq Run 40652: ND3 bottom Pol=-19.5 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37738 08/09/01 05:43 cdaq Run 40651: ND3 bottom Pol=-17.7 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37735 08/09/01 04:10 cdaq Run 40650: ND3 bottom Pol=-17.7 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37733 08/09/01 03:36 cdaq Run 40649: ND3 bottom Pol=-17.1 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37730 08/09/01 02:52 cdaq Run 40648: ND3 bottom Pol=-20.9 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37728 08/09/01 02:20 cdaq Run 40647: ND3 bottom Pol=-20.1 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37725 08/09/01 01:54 cdaq Run 40646: ND3 bottom Pol=-23.9 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37724 08/09/01 01:34 cdaq Run 40645: ND3 bottom Pol=-19.3 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37722 08/09/01 00:29 cdaq Run 40644: ND3 bottom Pol=-22.4 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37720 08/09/01 00:04 cdaq Run 40643: ND3 bottom Pol=-22.8 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
Wednesday
37717 08/08/01 23:38 cdaq Run 40642: ND3 bottom Pol=-21.4 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37716 08/08/01 23:10 cdaq Run 40641: ND3 bottom Pol=-26.5 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37714 08/08/01 22:37 cdaq Run 40640: ND3 bottom Pol=-21.6 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37713 08/08/01 22:12 cdaq Run 40639: ND3 bottom Pol=-21.7 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 STATIC
37711 08/08/01 21:44 cdaq Run 40638: ND3 bottom Pol=-20.0 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0 EVENT
37710 08/08/01 21:16 cdaq Run 40637: ND3 bottom Pol=-18.4 BAR thresh = 25mV SR=1.15 FR=ON SEM=19.2
37708 08/08/01 20:49 cdaq Run 40636: ND3 bottom Pol=-14.5 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0
37705 08/08/01 20:34 cdaq Run 40635: ND3 bottom Pol=-12.5 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0
37703 08/08/01 20:08 cdaq Run 40634: ND3 bottom Pol=+6.8 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0
37701 08/08/01 20:03 cdaq Run 40633: ND3 bottom Pol=+6.8 BAR thresh = 25mV SR=1.15 FR=ON SEM=20.0
37698 08/08/01 18:58 cdaq Run 40632: Carbon run BAR thresh = 25mV SR=1.15 FR=OFF
37696 08/08/01 18:10 cdaq Run 40631: cosmics run BAR thresh = 15mV, VETO thresh = 40mV
37694 08/08/01 17:44 cdaq Run 40630: ND3 Top SR=1.15,SEM=19.7,SEM=STATIC Pol==12.8 FR= ON
37691 08/08/01 16:20 cdaq Run 40629: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=-17.2 FR= ON
37686 08/08/01 15:52 cdaq Run 40628: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=-17.8 FR= ON
37685 08/08/01 15:45 cdaq Run 40627: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=-16.5 FR= ON
37684 08/08/01 15:12 cdaq Run 40626: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=-17.2 FR= ON
37682 08/08/01 14:41 cdaq Run 40625: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=-15.3 FR= ON
37680 08/08/01 14:31 cdaq Run 40624: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=-13.9 FR= ON
37678 08/08/01 14:00 cdaq Run 40623: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=-13.4 FR= ON
37677 08/08/01 13:29 cdaq Run 40622: Cosmic run. ND thresholds set at 40mv.
37656 08/08/01 08:55 cdaq Run 40614: Cosmic run.
37652 08/08/01 08:15 cdaq Run 40613: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+21.2 FR= ON
37648 08/08/01 07:49 cdaq Run 40612: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+21.3 FR= ON
37646 08/08/01 07:19 cdaq Run 40611: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+22.0 FR= ON
37643 08/08/01 06:48 cdaq Run 40610: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+21.1 FR= ON
37642 08/08/01 06:19 cdaq Run 40609: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+5.2 FR= ON
37637 08/08/01 03:34 cdaq Run 40608: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+22.8 FR= ON
37636 08/08/01 03:21 cdaq Run 40607: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+21.7 FR= ON
37634 08/08/01 02:51 cdaq Run 40606: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+21.7 FR= ON
37633 08/08/01 02:20 cdaq Run 40605: ND3 Bottom SR=1.15,SEM=19.7,SEM=EVENT Pol=+22.3 FR= ON
37631 08/08/01 01:51 cdaq Run 40604: ND3 Bottom SR=1.15,SEM=19.7,SEM=STATIC Pol=+25.0 FR= ON
37625 08/08/01 00:35 cdaq Run 40603: Carbon SR=1.15,SEM=19.8,SEM=STATIC
Tuesday
37622 08/07/01 23:52 cdaq Run 40602: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+14.3 FR= ON
37620 08/07/01 22:34 cdaq Run 40601: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+24.1 FR= ON
37619 08/07/01 22:14 cdaq Run 40600: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+24.1 FR= ON
37617 08/07/01 21:47 cdaq Run 40599: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+24.1 FR= ON
37615 08/07/01 21:13 cdaq Run 40598: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+24.1 FR= ON
37614 08/07/01 20:33 cdaq Run 40597: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+24.1 FR= ON
37612 08/07/01 20:06 cdaq Run 40596: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+29.1 FR= ON
37610 08/07/01 19:25 cdaq Run 40595: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+23.6 FR= ON
37606 08/07/01 18:58 cdaq Run 40594: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+22.9 FR= ON
37604 08/07/01 18:39 cdaq Run 40593: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+23.4 FR= ON
37603 08/07/01 18:15 cdaq Run 40592: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+21.6 FR= ON
37602 08/07/01 18:11 cdaq Run 40591: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+21.6 FR= ON
37601 08/07/01 18:05 cdaq Run 40590: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+21.6 FR= ON
37599 08/07/01 17:58 cdaq Run 40589: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+21.6 FR= ON
37596 08/07/01 17:21 cdaq Run 40588: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+16.3 FR= ON
37594 08/07/01 16:45 cdaq Run 40587: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+16.3 FR= ON
37590 08/07/01 16:32 cdaq Run 40586: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+14.4 FR= ON
37589 08/07/01 16:11 cdaq Run 40585: ND3 Bottom SR=1.15,SEM=19.8,SEM=STATIC Pol=+9.1 FR= ON
37586 08/07/01 15:37 cdaq Run 40584: 12C SR=1.15,SEM=19.9,SEM=Event, FR= OFF
37585 08/07/01 15:26 cdaq Run 40583: 12C SR=1.15,SEM=19.9,SEM=Event, FR=0.5 (on)
37583 08/07/01 14:59 cdaq Run 40582: 12C SR=1.15,SEM=19.9,SEM=STATIC
37580 08/07/01 14:30 cdaq Run 40581: 12C SR=1.15,SEM=19.9,SEM=STATIC
37578 08/07/01 14:01 cdaq Run 40580: 12C SR=1.15,SEM=19.9,SEM=STATIC
37577 08/07/01 13:35 cdaq Run 40579: 12C SR=1.15,SEM=19.9,SEM=STATIC
37569 08/07/01 10:46 cdaq Run 40578: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-19.6
37568 08/07/01 10:19 cdaq Run 40577: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-21.0
37565 08/07/01 09:48 cdaq Run 40576: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-20.3
37564 08/07/01 09:21 cdaq Run 40575: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-22.0
37562 08/07/01 09:06 cdaq Run 40574: ND3 top Testrun, junk, took ndet cable 4left out
37560 08/07/01 08:33 cdaq Run 40573: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-21.3
37557 08/07/01 08:01 cdaq Run 40572: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-22.0
37555 08/07/01 07:35 cdaq Run 40571: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-21.6
37554 08/07/01 07:06 cdaq Run 40570: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-22.0
37552 08/07/01 06:39 cdaq Run 40569: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-23.1
37547 08/07/01 03:04 cdaq Run 40568: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-22.4
37545 08/07/01 02:46 cdaq Run 40567: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-24.1
37544 08/07/01 02:15 cdaq Run 40566: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-23.1
37541 08/07/01 01:48 cdaq Run 40565: ND3 top SR=1.15,SEM=19.9,SEM=EVENT pol=-23.3
37540 08/07/01 01:21 cdaq Run 40564: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-23.6
37539 08/07/01 00:55 cdaq Run 40563: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-24.1
37537 08/07/01 00:28 cdaq Run 40562: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-24.6
37535 08/07/01 00:06 cdaq Run 40561: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-25.1
Monday
37532 08/06/01 23:39 cdaq Run 40560: ND3 top SR=1.15,SEM=19.9,SEM=STATIC pol=-27.1
37530 08/06/01 23:17 cdaq Run 40559: ND3 top, SR=1.15,SEM=19.9,SEM=STATIC pol=+25.2
37527 08/06/01 22:46 cdaq Run 40558: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+24.9
37526 08/06/01 22:16 cdaq Run 40557: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+25.2
37524 08/06/01 21:48 cdaq Run 40556: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+24.3
37523 08/06/01 21:29 cdaq Run 40555: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+24.8
37522 08/06/01 21:12 cdaq Run 40554: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=-22.8
37521 08/06/01 21:06 cdaq Run 40553: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC,Pol=-21.1%
37518 08/06/01 20:37 cdaq Run 40552: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC,Pol=-21.1%
37517 08/06/01 20:16 cdaq Run 40551: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC,Pol=-17%
37513 08/06/01 19:53 cdaq Run 40550: ND3 top, SR=1.15,SEM=19.5,SEM=EVENT,Pol=-14%
37512 08/06/01 19:51 cdaq Run 40549: ND3 top, SR=1.15,SEM=19.5,SEM=EVENT,Pol=-14%
37510 08/06/01 18:00 cdaq Run 40548: SR pulser test run
37509 08/06/01 17:02 cdaq Run 40547: SR pulser test run
37508 08/06/01 16:49 cdaq Run 40546: SR pulser test run
37507 08/06/01 16:37 cdaq Run 40545: SR pulser test run
37506 08/06/01 16:24 cdaq Run 40544: SR pulser test run
37505 08/06/01 16:14 cdaq Run 40543: SR pulser test run
37486 08/06/01 10:54 cdaq Run 40528: Laser run.
37483 08/06/01 08:34 cdaq Run 40527: 12C SR=1.15,SEM=19.9,SEM=STATIC, I=200 nA.
37479 08/06/01 07:59 cdaq Run 40526: 12C SR=1.15,SEM=19.9,SEM=STATIC, I=200 nA.
37478 08/06/01 07:19 cdaq Run 40525: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+19.9
37476 08/06/01 06:47 cdaq Run 40524: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+19.3
37475 08/06/01 06:29 cdaq Run 40523: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+19.4
37473 08/06/01 06:04 cdaq Run 40522: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+20.2
37471 08/06/01 05:35 cdaq Run 40521: ND3 bottom, SR=1.15,SEM=19.9,SEM=EVENT pol=+20.5
37469 08/06/01 05:01 cdaq Run 40520: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+21.4
37468 08/06/01 04:34 cdaq Run 40519: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+22.0
37466 08/06/01 04:07 cdaq Run 40518: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+20.9
37464 08/06/01 03:39 cdaq Run 40517: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+23.5
37463 08/06/01 03:32 cdaq Run 40516: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+25.5
37461 08/06/01 02:58 cdaq Run 40515: ND3 bottom, SR=1.15,SEM=19.9,SEM=STATIC pol=+20.0
37460 08/06/01 02:20 cdaq Run 40514: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+18.5
Sunday
37451 08/05/01 17:21 cdaq Run 40513: No beam, Dummy run.
37449 08/05/01 16:31 cdaq Run 40512: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+26.8
37448 08/05/01 16:25 cdaq Run 40511: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+26.8
37443 08/05/01 15:51 cdaq Run 40510: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+36.0
37442 08/05/01 15:48 cdaq Run 40509: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+36.0
37440 08/05/01 14:27 cdaq Run 40508: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+31.7
37439 08/05/01 14:22 cdaq Run 40507: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+26.0
37437 08/05/01 13:49 cdaq Run 40506: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+33.3
37434 08/05/01 13:00 cdaq Run 40505: ND3 bottom, SR=1.15,SEM=20.1,SEM=STATIC pol=+26.0
37433 08/05/01 12:32 cdaq Run 40504: ND3 bottom, SR=1.15,SEM=19.5,SEM=STATIC pol=+24.3
37432 08/05/01 11:55 cdaq Run 40503: ND3 bottom, SR=1.15,SEM=19.5,SEM=STATIC pol=+21.7
37430 08/05/01 11:07 cdaq Run 40502: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=+?
37428 08/05/01 09:33 cdaq Run 40501: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-17.0
37426 08/05/01 09:01 cdaq Run 40500: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-17.8
37425 08/05/01 08:58 cdaq Run 40499: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-17.2
37424 08/05/01 08:27 cdaq Run 40498: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-18.0
37422 08/05/01 07:58 cdaq Run 40497: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-18.0
37420 08/05/01 07:29 cdaq Run 40496: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.8
37419 08/05/01 07:23 cdaq Run 40495: ND3 top, SR=1.15, SEM=EVENT, pol=-18.9
37418 08/05/01 06:54 cdaq Run 40494: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.2
37414 08/05/01 06:26 cdaq Run 40493: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.7
37413 08/05/01 06:20 cdaq Run 40492: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.7
37410 08/05/01 05:27 cdaq Run 40491: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-22.5
37407 08/05/01 05:16 cdaq Run 40490: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-20.9
37405 08/05/01 04:41 cdaq Run 40489: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-23.9
37403 08/05/01 04:25 cdaq Run 40488: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-22.5
37399 08/05/01 02:28 cdaq Run 40487: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-20.8
37398 08/05/01 01:57 cdaq Run 40486: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-22.0
37394 08/05/01 01:28 cdaq Run 40485: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-21.8
37393 08/05/01 00:57 cdaq Run 40484: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-22.2
37391 08/05/01 00:27 cdaq Run 40483: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-22.5
37390 08/05/01 00:10 cdaq Run 40482: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-23.5
Saturday
37387 08/04/01 23:39 cdaq Run 40481: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-22.5
37386 08/04/01 23:09 cdaq Run 40480: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-23.1
37384 08/04/01 22:32 cdaq Run 40479: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=24.7
37381 08/04/01 22:25 cdaq Run 40478: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.2
37380 08/04/01 21:56 cdaq Run 40477: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.2
37379 08/04/01 21:19 cdaq Run 40476: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.2
37378 08/04/01 21:14 cdaq Run 40475: ND3 top, SR=1.15,SEM=19.5,SEM=STATIC pol=-19.2
37377 08/04/01 20:45 cdaq Run 40474: ND3 top, SR=1.15,SEM=19.5,SEM=EVENT mode
37376 08/04/01 20:16 cdaq Run 40473: ND3 top, SR=1.15,SEM=19.5,SEM=Static
37371 08/04/01 07:46 cdaq Run 40472: Carbon, SR=1.15,SEM=19.5,SEM=Static
37370 08/04/01 07:36 cdaq Run 40471: Carbon, SR=1.15,SEM=19.5,SEM=Static
37369 08/04/01 07:10 cdaq Run 40470: Carbon, SR=1.15,SEM=19.5,SEM=Static
37368 08/04/01 06:33 cdaq Run 40469: Carbon, SR=1.15,SEM=19.5,SEM=Static
37367 08/04/01 05:56 cdaq Run 40468: Carbon, SR=1.15,SEM=19.5,SEM=Static
37365 08/04/01 04:28 cdaq Run 40467: Carbon, Helium, SR=1.15,SEM=19.5,SEM=Static
37364 08/04/01 04:03 cdaq Run 40466: Carbon, Helium, SR=1.15,SEM=19.5,SEM=Static
37363 08/04/01 03:33 cdaq Run 40465: Carbon, Helium, SR=1.15,SEM=19.5,SEM=Static
37362 08/04/01 03:08 cdaq Run 40464: Carbon, Helium, SR=1.15,SEM=19.5,SEM=Static
37359 08/04/01 02:30 cdaq Run 40463: ND3 bottom, SR=1.15,SEM=19.5,Pd=-13.6 SEM=Static
37358 08/04/01 02:00 cdaq Run 40462: ND3 bottom, SR=1.15,SEM=19.5,Pd=-14.2 SEM=Static
37356 08/04/01 01:27 cdaq Run 40461: ND3 bottom, SR=1.15,SEM=19.5,Pd=-14.4 SEM=Static
37354 08/04/01 00:54 cdaq Run 40460: ND3 bottom, SR=1.15,SEM=19.5,Pd=-14.7 SEM=Static
37353 08/04/01 00:21 cdaq Run 40459: ND3 bottom, SR=1.15,SEM=19.5,Pd=-15.4 SEM=Static
37352 08/04/01 00:03 cdaq Run 40458: ND3 bottom, SR=1.15,SEM=19.5,Pd=-15.0 SEM=Static
Friday
37348 08/03/01 23:33 cdaq Run 40457: ND3 bottom, SR=1.15,SEM=19.5,Pd=-175.9SEM=STATIC
37347 08/03/01 23:10 cdaq Run 40456: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.0 SEM=EVENT
37346 08/03/01 22:53 cdaq Run 40455: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.0 SEM=EVENT
37344 08/03/01 22:22 cdaq Run 40454: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.0 SEM=EVENT
37343 08/03/01 22:19 cdaq Run 40453: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.0 SEM=EVENT
37341 08/03/01 22:16 cdaq Run 40452: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.0 SEM=EVENT
37339 08/03/01 22:07 cdaq Run 40451: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.4 SEM=EVENT
37338 08/03/01 22:02 cdaq Run 40450: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.4 SEM=EVENT
37337 08/03/01 21:54 cdaq Run 40449: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.4 SEM=Static
37336 08/03/01 21:42 cdaq Run 40448: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.2 SEM=Static
37335 08/03/01 21:28 cdaq Run 40447: ND3 bottom, SR=1.15,SEM=19.5,Pd=-16.9 SEM=Static
37334 08/03/01 21:00 cdaq Run 40446: ND3 bottom, SR=1.15,SEM=19.5,Pd=-16.9 SEM=Static
37333 08/03/01 20:33 cdaq Run 40445: ND3 bottom, SR=1.15,SEM=19.5,Pd=-18.7 SEM=Static
37329 08/03/01 20:05 cdaq Run 40444: ND3 bottom, SR=1.15,SEM=19.5,Pd=-18.4 SEM=Static
37328 08/03/01 19:49 cdaq Run 40443: ND3 bottom, SR=1.15,SEM=19.5,Pd=-18.9 SEM=Static
37326 08/03/01 19:31 cdaq Run 40442: ND3 bottom, SR=1.15,SEM=19.5,Pd=-18.9 SEM=Static
37325 08/03/01 19:04 cdaq Run 40441: ND3 bottom, SR=1.15,SEM=19.5,Pd=-19.2 SEM=Static
37323 08/03/01 18:47 cdaq Run 40440: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.5 SEM=Static
37322 08/03/01 18:46 cdaq Run 40439: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.5 SEM=Static
37321 08/03/01 18:18 cdaq Run 40438: ND3 bottom, SR=1.15,SEM=19.5,Pd=-17.5 SEM=Static
37320 08/03/01 18:06 cdaq Run 40437: ND3 bottom, SR=1.15,SEM=19.5,Pd=19.6 SEM=Eventmode
37318 08/03/01 17:36 cdaq Run 40436: ND3 bottom, SR=1.15,SEM=19.5,Pd=19.6
37315 08/03/01 14:25 cdaq Run 40435: ND3 top, SR=1.05,SEM=18.5,Pd=17.0
37313 08/03/01 13:49 cdaq Run 40434: ND3 top, SR=1.05,SEM=18.5,Pd=16.9
37312 08/03/01 13:21 cdaq Run 40433: ND3 top, SR=1.05,SEM=18.5,Pd=17.4
37310 08/03/01 12:45 cdaq Run 40432: ND3 top, SR=1.05,SEM=18.5,Pd=17.6
37309 08/03/01 12:16 cdaq Run 40431: ND3 top, SR=1.05,SEM=18.5,Pd=18.3
37307 08/03/01 11:46 cdaq Run 40430: ND3 top, SR=1.05,SEM=18.5,Pd=18.6
37306 08/03/01 11:38 cdaq Run 40429: ND3 top, SR=1.05,SEM=18.5,Pd=19.6, Event mode
37301 08/03/01 08:12 cdaq Run 40428: ND3 top, SR=1.05,SEM=18.5,Pd=18.6
37298 08/03/01 07:43 cdaq Run 40427: ND3 top, SR=1.05,SEM=18.5,Pd=19.2
37296 08/03/01 07:18 cdaq Run 40426: ND3 top, SR=1.3,SEM=20.1,Pd=19.2
37294 08/03/01 06:31 cdaq Run 40425: ND3 top, SR=1.3,SEM=20.1,Pd=19.6%
37293 08/03/01 06:01 cdaq Run 40424: ND3 top, SR=1.3,SEM=20.1,Pd=20.5
37290 08/03/01 05:31 cdaq Run 40423: ND3 top, SR=1.3,SEM=20.1,Pd=20.5
37288 08/03/01 04:55 cdaq Run 40422: ND3 top, SR=1.3,SEM=20.1,Pd=19.1
37286 08/03/01 04:22 cdaq Run 40421: ND3 top, SR=1.3,SEM=20.1,Pd=21.6%
37279 08/03/01 02:22 cdaq Run 40420: ND3 top, SR=1.3,SEM=20.1
Thursday
37251 08/02/01 15:17 cdaq Run 40407: Carbon target, SR=1.3,SEM=20.7
37250 08/02/01 14:20 cdaq Run 40406: Carbon target, SR=1.3,SEM=20.7
37247 08/02/01 13:24 cdaq Run 40405: ND3 BOT, SR=1.3,SEM=20.1
37246 08/02/01 12:47 cdaq Run 40404: Carbon Target, SR=1.2,SEM=20.4
37243 08/02/01 12:02 cdaq Run 40403: ND3 BOT, SR=1.2,SEM=20.4;Pd=-16.5%
37242 08/02/01 11:35 cdaq Run 40402: ND3 BOT, SR=1.2,SEM=20.4;Pd=-14.0%
37241 08/02/01 11:28 cdaq Run 40401: ND3 BOT, SR=1.2,SEM=20.4, Pd =-14.1%;Event mode
37239 08/02/01 10:59 cdaq Run 40400: ND3 BOT, SR=1.2,SEM=20.4
37238 08/02/01 10:28 cdaq Run 40399: ND3 BOT, SR=1.2,SEM=20.4
37236 08/02/01 09:58 cdaq Run 40398: ND3 BOT, SR=1.2,SEM=20.4
37233 08/02/01 08:44 cdaq Run 40397: ND3 BOT, SR=1.2,SEM=20.4
37232 08/02/01 08:27 cdaq Run 40396: pion collimator
37228 08/02/01 07:51 cdaq Run 40395: pion collimator
37227 08/02/01 07:21 cdaq Run 40394: pion collimator
37225 08/02/01 06:47 cdaq Run 40393: pion collimator
37217 08/02/01 01:22 cdaq Run 40392: pion collimator
37215 08/02/01 00:45 cdaq Run 40391: pion collimator
37213 08/02/01 00:28 cdaq Run 40390: pion collimator
Wednesday
37205 08/01/01 23:24 cdaq Run 40389: pion collimator
37204 08/01/01 23:02 cdaq Run 40388: pion collimator
37203 08/01/01 22:30 cdaq Run 40387: ND3 TOP target
37201 08/01/01 21:58 cdaq Run 40386: ND3 TOP target
37198 08/01/01 21:29 cdaq Run 40385: ND3 TOP target
37197 08/01/01 20:58 cdaq Run 40384: ND3 TOP target
37195 08/01/01 20:25 cdaq Run 40383: ND3 TOP target
37193 08/01/01 19:58 cdaq Run 40382: ND3 TOP target
37192 08/01/01 19:38 cdaq Run 40381: ND3 TOP target
37190 08/01/01 19:28 cdaq Run 40380: ND3 TOP target
37188 08/01/01 19:02 cdaq Run 40379: ND3 TOP target, SR=1.2, SEM=19.7
37186 08/01/01 18:40 cdaq Run 40378: ND3 TOP target, SR=1.2, SEM=20.1
37184 08/01/01 18:20 cdaq Run 40377: ND3 TOP target, SR=1.2, SEM=20.1
37183 08/01/01 17:53 cdaq Run 40376: ND3 TOP target, SR=1.2, SEM=20.1
37182 08/01/01 17:24 cdaq Run 40375: ND3 TOP target, SR=1.2, SEM=20.1
37177 08/01/01 16:24 cdaq Run 40374: Cu target, SR=1.3, SEM=22.5 pulser run
37176 08/01/01 16:18 cdaq Run 40373: Cu target, SR=1.3, SEM=22.5
37175 08/01/01 16:07 cdaq Run 40372: Cu target, SR=1.0, SEM=17.6
37174 08/01/01 15:59 cdaq Run 40371: Cu target, SR=1.0, SEM=17.6
37172 08/01/01 15:47 cdaq Run 40370: Cu target, SR=0.7, SEM=12.0
37171 08/01/01 15:43 cdaq Run 40369: Cu target, SR=0.7, SEM=12.0
37170 08/01/01 15:35 cdaq Run 40368: DAQ test
37169 08/01/01 15:16 cdaq Run 40367: DAQ test
37167 08/01/01 15:10 cdaq Run 40366: DAQ test
37166 08/01/01 15:04 cdaq Run 40365: DAQ test
37165 08/01/01 14:45 cdaq Run 40364: DAQ test
37164 08/01/01 14:41 cdaq Run 40363: DAQ test
37160 08/01/01 12:23 cdaq Run 40362: laser test run, 20% transmittance
37159 08/01/01 12:04 cdaq Run 40361: laser test run
37158 08/01/01 11:37 cdaq Run 40360: laser test run
37157 08/01/01 11:19 cdaq Run 40359: DAQ test run