Main INDEX
Monthly INDEX
PREV
NEXT
User name hamlet
Log entry time 00:01:53 on December 21,2001
Entry number 45432
keyword=Shift summary
16:00 Start shift with production run 43009 on 'top' ND3 target.
17:00 End data taking. Ask MCC take beam 'off' for target annealing.
17:05 Took cosmic runs (level 1 and short one for level 2 ) during target annealing.
18:20 Change disk from data2 to data3. Start 'cosmic level 1' run 43014.
19:05 End cosmics. Will put carbon target on the beam.
19:10 Ask MCCS for 100nA beam, start taking data on carbon (run 43016).
19:40 End run 43016. Ask MCC take beam off to move target (for polarization).
20:00 Start data taking on bopttom ND3 target, polarization +41.2%.
21:30 DAQ problem, ROC2 and then TSO died, kill all and reboot ROC2 & TSO.
21:45 Back to data taking. Start run 43020 on bottom ND3, P=+29.5%.
22:50 Start run 43021, bottom. P=+26.7%.
23:50 Start run 43022, bottom P =+25.0%.