Beam Energy (MeV) | 5759 | 5759 |
HMS Momentum (GeV/c) | 4.095 | 4.095 |
HMS Angle | -1074.86 | -1074.86 |
Q1 Set Current | 1.000 | 1.000 |
Q2 Set Current | -422.950 | -422.950 |
Q3 Set Current | 206.308 | 206.321 |
Q1 B Field (G) | 7310.7000 | 7310.7000 |
Q2 B Field (G) | -8591.9000 | -8592.0000 |
Q3 B Field (G) | 4077.0000 | 4077.2000 |
D Current Readback | -1256.730 | -1256.730 |
B_true | -1.1221645 | -1.1221685 |
Target Encoder | 3.246 | 3.596 |
Target Insert | 2 | 2 |
Target Position | 1 | 1 |
Target Polarization | -0.1 | 0 |
Target Field (T) | 5.003 | 0.000 |
Targ Acc Charge (10^15 e-) | 0.000 | 0.000 |
Beam Current (nA) | 100 | 100 |
SEM pos x,y (mm) | 0.0,0.0 | 0.0,0.0 |
SEM dia x,y (mm) | 0.0,0.0 | 0.0,0.0 |
SEM mode | event | event |
Fast Raster dia (mm) | 0 | 0 |
Top Cell, Encoder=3.596, I=100 nA
10 mm SR, 1 mm FR Lissajous
BPM: X = -1.2 Y1 = -0.1
Pion collimator