• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name Louis/Retief

    Log entry time 22:13:47 on December 8,2002

    Entry number 53533

    Followups:

    keyword=Summary of Cables exchange study

    Cables from detectors 1 & 8 have been exchanged between octants 1 & 8 (too!)
    after adding 4nsec cables on the 16 required channel.
    Detector 12 of each octant was kept unchanged but with HV on for reference purpose.

    The Runs numbers for this study are :

    French Cables on French electronics
    14932 : FullGain HV only on involved detectors
    [30'] FiB,no NPN,Th=25mV,n=5,
    ts_full, Fastbus (no fastclear) and TED interleaved PS4=3000

    14933 : FullGain HV only on involved detectors
    [22'] ts_full, Fastbus (fastclear) NO TED

    14934: FullGain HV only on involved detectors
    [28'] FoB, no NPN, Th=25mV, n=5
    ts_full, Fastbus (no fastclear) and TED interleaved PS4=3000
    =======================================================

    NA cables on French electronics

    14935: FullGain HV only on involved detectors
    [35'] FoB, no NPN, Th=25mV, n=5
    ts_full, Fastbus (no fastclear) and TED interleaved PS4=3000

    14936: FullGain HV only on involved dectectors
    [35'] FiB, no NPN. Th=25mV, n=5
    ts_full. Fastbus (no fastclear) and TED interleaved PS4=300

    14937: FullGain HV only on involved detectors
    [34'] ts_full, Fastbus (with fastclear) no TED

    And that's it.