Here is a summary of the G0Integrity files for the period from 12:00 - 20:00.
================================================================
Run 21966 - LH2 production run, GMS off, 40 uA, IHWP =OUT. Hall A isoff for controlled access
charge asymmetry (ppm) : 58.7 ( 6.6) ** out of acceptable range **
Normalized rates from TE data
total (proton)
ring | Fr | NA
09 | 113.9 ( 60.8) | 114.7 ( 61.8) ** out of acceptable range **
Proton asymmetries width normalized to statistical expectation
ring | Fr | NA
13 | 1.38 ( 0.02) | 1.04 ( 0.02) ** out of acceptable range **
14 | 1.31 ( 0.02) | 1.07 ( 0.01) ** out of acceptable range **
================================================================
Run 21967 - LH2 production run, GMS off, 40 uA, IHWP =OUT
charge asymmetry (ppm) : 84.8 ( 13.7) ** out of acceptable range **
Normalized rates from TE data
total (proton)
ring | Fr | NA
09 | 113.6 ( 60.7) | 114.4 ( 61.7) ** out of acceptable range **
Proton asymmetries width normalized to statistical expectation
ring | Fr | NA
13 | 1.36 ( 0.02) | 1.05 ( 0.01) ** out of acceptable range **
14 | 1.28 ( 0.02) | 1.06 ( 0.01) ** out of acceptable range **
================================================================
Run 21968 - Hall A Leakage study, lumis on high gain, IHWP =OUT
There are 212 values out of range for this run
================================================================
Run 21969 - LH2 production run, 40 uA, IHWP =OUT
charge asymmetry (ppm) : -79.0 ( 11.4) ** out of acceptable range **
Normalized rates from TE data
total (proton)
ring | Fr | NA
09 | 113.8 ( 60.8) | 114.7 ( 61.8) ** out of acceptable range **
Proton asymmetries width normalized to statistical expectation
ring | Fr | NA
13 | 1.38 ( 0.02) | 1.06 ( 0.01) ** out of acceptable range **
14 | 1.35 ( 0.02) | 1.06 ( 0.01) ** out of acceptable range **
================================================================
Run 21970 - Leakage study. Hall A on. lumi gains increased
There are 190 values out of range for this run
================================================================
Run 21971: leakage study. Hall A on. Hall C slits open but beam off
There are 126 values out of range for this run
================================================================
Run 21972 - LH2 production run, 40 uA, IHWP =IN
Normalized rates from TE data
total (proton)
ring | Fr | NA
09 | 113.8 ( 60.8) | 114.8 ( 61.8) ** out of acceptable range **
Proton asymmetries width normalized to statistical expectation
ring | Fr | NA
13 | 1.21 ( 0.02) | 1.03 ( 0.01) ** out of acceptable range **
14 | 1.18 ( 0.02) | 1.06 ( 0.01) ** out of acceptable range **
================================================================
Run 21973 - Leakage run, A,B on, IHWP =IN
There are 126 values out of range for this run
================================================================
Run 21974 - LH2 production run, GMS off, 40 uA, IHWP =IN
charge asymmetry (ppm) : 455.0 ( 23.2) ** out of acceptable range **
x position difference (nm) : 4550.2 (226.7) ** out of acceptable range **
y position difference (nm) : 391.5 (146.5) ** out of acceptable range **
Normalized rates from TE data
total (proton)
ring | Fr | NA
09 | 113.4 ( 60.7) | 114.7 ( 61.9) ** out of acceptable range **
Proton asymmetries width normalized to statistical expectation
ring | Fr | NA
13 | 1.20 ( 0.02) | 1.04 ( 0.01) ** out of acceptable range **
14 | 1.16 ( 0.01) | 1.04 ( 0.01) ** out of acceptable range **
================================================================
Run 21975 - LH2 production run, GMS off, 40 uA, IHWP =IN
Normalized rates from TE data
total (proton)
ring | Fr | NA
09 | 113.2 ( 60.6) | 114.3 ( 61.8) ** out of acceptable range **
Proton asymmetries width normalized to statistical expectation
ring | Fr | NA
13 | 1.17 ( 0.02) | 1.04 ( 0.01) ** out of acceptable range **
14 | 1.20 ( 0.02) | 1.06 ( 0.01) ** out of acceptable range **
================================================================