89244 09/30/04 23:43 Tvaskis Shift Summary
89243 09/30/04 23:41 mbukhari target shift checklist screen
89242 09/30/04 23:41 cdaq Run 50520: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: 3%C
89241 09/30/04 23:40 mbukhari Target changed Aluminium Dummy -> 3% C
89240 09/30/04 23:38 mb
89239 09/30/04 23:33 segbefia
89238 09/30/04 23:17 cdaq Run 50519: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: Al (dummy)
89237 09/30/04 23:01 cdaq Run 50518: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: Al (dummy)
89236 09/30/04 22:45 mbukhari Target changed He3-> Aluminium Dummy
89235 09/30/04 22:04 cdaq Run 50517: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: He-3
89234 09/30/04 21:45 cdaq Run 50516: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: He-3
89233 09/30/04 21:42 mbukhari Target changed He4->He3
89232 09/30/04 21:32 cdaq Run 50514: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: He-4
89231 09/30/04 21:27 mbukhari Target changed He4->He3
89230 09/30/04 20:40 cdaq Run 50513: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: He-4
89229 09/30/04 20:23 cdaq Run 50512: Production run, HMS 22.0 deg, -3.44 GeV, SOS 50 deg, P=-1.59 Target: He-4
89228 09/30/04 19:20 cdaq Run 50511: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.36 Target: He-4
89227 09/30/04 19:06 cdaq Run 50510: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.36 Target: He-4
89226 09/30/04 18:54 mbukhari Target changed He3->He4
89225 09/30/04 18:35 cdaq Run 50509: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.36 Target: 3%C
89224 09/30/04 18:09 cdaq Run 50508: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.36 Target: 3%C
89223 09/30/04 18:04 mbukhari Target movement: 3He -> C 3%
89222 09/30/04 17:55 cdaq Run 50507: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.36 Target: 3%C
89221 09/30/04 17:16 cdaq Run 50506: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.36 Target: He-3
89220 09/30/04 16:46 cdaq Run 50505: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.17 Target: He-3
89219 09/30/04 16:12 X. Zheng day shift summary
89218 09/30/04 16:07 cdaq Beam Time Accounting
89217 09/30/04 14:19 Holt Helium-4 target pressure was increased during the beam studies
89216 09/30/04 14:10 gaskell access work
89215 09/30/04 10:52 Holt Helium targets are parked because of beam studies
89214 09/30/04 10:51 Holt
89213 09/30/04 09:30 cdaq Run 50504: Production run, HMS 22.0 deg, -4.02 GeV, SOS 50 deg, P=-1.36 Target: Al Dummy
89212 09/30/04 09:10 horn Owl Shift Summary
89210 09/30/04 08:58 Holt Al dummy target is in the beam
89209 09/30/04 08:46 cdaq Run 50503: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.17 Target: Al Dummy
89208 09/30/04 08:06 cdaq Beam Time Accounting
89207 09/30/04 08:04 cdaq Run 50502: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.17 Target: He-4
89206 09/30/04 07:25 trojer Target changed
89205 09/30/04 07:15 cdaq Run 50501: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.17 Target: He-4
89204 09/30/04 06:04 cdaq Run 50500: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.17 Target: He-3
89203 09/30/04 05:06 cdaq Run 50499: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.17 Target: He-3
89202 09/30/04 04:05 cdaq Run 50498: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.17 Target: He-3
89201 09/30/04 02:57 cdaq Run 50497: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: He-3
89200 09/30/04 02:14 trojer target checklist
89199 09/30/04 01:57 cdaq Run 50496: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: He-3
89198 09/30/04 00:56 cdaq Run 50495: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: He-3
89197 09/30/04 00:47 trojer Target changed He4->He3
89196 09/30/04 00:10 cdaq Beam Time Accounting
Wednesday
89195 09/29/04 23:55 cdaq Run 50494: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: He-4
89194 09/29/04 23:51 Tvaskis Shift Summary
89193 09/29/04 23:30 cdaq Run 50493: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: He-4
89192 09/29/04 23:14 cdaq Run 50492: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: He-4
89191 09/29/04 23:08 simona BCM and BPM Screens
89190 09/29/04 22:51 Tvaskis target changed
89189 09/29/04 22:45 cdaq Run 50491: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: He-4
89188 09/29/04 22:20 Tvaskis data on dummy
89187 09/29/04 22:14 cdaq Run 50490: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-1.00 Target: Al(dummy)
89186 09/29/04 21:41 cdaq Run 50489: Production run, HMS 22.0 deg, -4.653 GeV, SOS 50 deg, P=-0.86 Target: Al(dummy)
89185 09/29/04 21:40 gaskell ready for beam after dummy test
89184 09/29/04 21:08 cseely yields before and after high current on dummy target
89183 09/29/04 20:16 cdaq Run 50488: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=-0.86 Target: Al(dummy)
89182 09/29/04 19:53 cdaq Run 50487: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=-0.86 Target: Al(dummy)
89181 09/29/04 19:48 gaskell Dummy damage test run
89180 09/29/04 19:42 cdaq Run 50486: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=-0.86 Target: Al(dummy)
89179 09/29/04 19:08 Tvaskis target changed
89178 09/29/04 18:55 cdaq Run 50485: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: Al(dummy)
89177 09/29/04 18:31 Tvaskis target changed
89176 09/29/04 18:20 cdaq Run 50484: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He4
89175 09/29/04 17:51 cdaq Run 50483: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He4
89174 09/29/04 17:20 cdaq Run 50482: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He4
89173 09/29/04 16:30 cdaq Run 50481: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He3
89172 09/29/04 16:02 cdaq Beam Time Accounting
89171 09/29/04 16:01 cdaq Run 50480: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He3
89170 09/29/04 16:01 X. Zheng day shift summary
89169 09/29/04 15:32 cdaq Run 50479: Junk, just checking to see if the angle grabbing program is still working, had a power outage, cdaql2 rebooted.
89168 09/29/04 14:34 cdaq Run 50478: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He3
89167 09/29/04 14:26 fomin bcm and bpm screens
89166 09/29/04 13:44 fomin HMS dipole ramp up error
89165 09/29/04 13:35 cdaq Run 50477: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He3
89164 09/29/04 13:32 cdaq Run 50476: Production run, HMS 22.0 deg, -4.653GeV, SOS 50 deg, P=-0.86 Target: He3
89163 09/29/04 13:31 X. Zheng configuration change to setting VI
89162 09/29/04 13:14 Holt 3He target moved into beam
89161 09/29/04 12:39 cdaq Run 50475: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: C3%
89160 09/29/04 12:20 cdaq Run 50474: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: C3%
89159 09/29/04 12:00 cdaq Run 50473: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: C3%
89158 09/29/04 11:59 Holt 3(2)% carbon target moved into beam
89157 09/29/04 11:52 fomin BCM1 seems to be the bad bcm
89156 09/29/04 10:55 cdaq Run 50472: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: He3
89155 09/29/04 09:56 cdaq Run 50471: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: He3
89154 09/29/04 09:46 Holt target checklist
89153 09/29/04 09:15 Holt 3He target moved into beam
89152 09/29/04 09:15 cdaq Run 50470: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: He3
89151 09/29/04 08:45 cdaq Run 50469: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: Al Dummy
89150 09/29/04 08:21 cdaq Beam Time Accounting
89149 09/29/04 07:41 cdaq Run 50468: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: He4
89148 09/29/04 07:05 cdaq Run 50467: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: He4
89147 09/29/04 07:00 cseely ending run failed 50464. killed CODA and restarted
89146 09/29/04 06:56 cdaq Run 50466: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: He4
89145 09/29/04 06:49 cdaq Run 50465: Production run, HMS 40.0 deg, -1.14 GeV, SOS 50 deg, P=+1.70 Target: He4
89144 09/29/04 06:11 cdaq Run 50464: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He4
89143 09/29/04 06:07 trojer Target changed
89142 09/29/04 05:44 cdaq Run 50463: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He4
89141 09/29/04 05:28 cdaq Run 50462: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He4
89140 09/29/04 05:01 cseely run 50461 is He4, not He3
89139 09/29/04 04:55 cdaq Run 50461: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He3
89138 09/29/04 04:04 cdaq Run 50460: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He3
89137 09/29/04 03:48 trojer target checklist
89136 09/29/04 03:47 trojer Target changed
89135 09/29/04 03:31 cdaq Run 50459: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He3
89134 09/29/04 03:03 cdaq Run 50458: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He3
89133 09/29/04 02:38 cdaq Run 50457: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He3
89132 09/29/04 02:03 cdaq Run 50456: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: He3
89131 09/29/04 01:28 cdaq Run 50455: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: Al_D
89130 09/29/04 01:00 cdaq Run 50454: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: C_0.03
89129 09/29/04 00:22 cdaq Run 50453: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: C_0.03
89128 09/29/04 00:20 cdaq Run 50452: Production run, HMS 40.0 deg, -1.33 GeV, SOS 50 deg, P=+1.70 Target: C_0.03
89127 09/29/04 00:17 Tvaskis shift summary
89126 09/29/04 00:11 segbefia
89125 09/29/04 00:09 cdaq Beam Time Accounting
89124 09/29/04 00:07 simona
Tuesday
89123 09/28/04 23:55 segbefia high power heater
89122 09/28/04 23:45 cdaq Run 50451: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: C(3%)
89121 09/28/04 23:12 Tvaskis target changed
89120 09/28/04 23:10 cdaq Run 50450: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: C(3%)
89119 09/28/04 22:53 cdaq Run 50449: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: Al(dummy)
89118 09/28/04 22:41 Tvaskis target changed
89117 09/28/04 22:39 cdaq Run 50448: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: Al(dummy)
89116 09/28/04 22:11 cdaq Run 50447: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89115 09/28/04 21:54 cdaq Run 50446: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89114 09/28/04 21:39 Tvaskis beam info
89113 09/28/04 21:34 gaskell harp scan results
89112 09/28/04 21:27 cdaq Run 50445: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89111 09/28/04 21:21 cdaq Run 50444: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89110 09/28/04 20:32 gaskell no beam
89109 09/28/04 16:07 X. Zheng day shift summary
89108 09/28/04 16:07 cdaq Beam Time Accounting
89107 09/28/04 16:05 segbefia target_checklist
89106 09/28/04 13:22 Holt Coolant flow to loop2 reduced since beam is off.
89105 09/28/04 10:36 gaskell "good" BCM run 50442
89104 09/28/04 10:14 Holt Empty target moved in for beam studies
89103 09/28/04 09:46 Holt 3He target moved into beam
89102 09/28/04 09:46 cdaq Run 50443: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89101 09/28/04 08:48 gaskell too many trips - BCM cal run no good
89100 09/28/04 08:30 cseely owl shift summary
89099 09/28/04 08:25 cdaq Run 50442: bcm calibration
89098 09/28/04 08:18 cdaq Run 50441: BCM Calibration
89097 09/28/04 08:16 Holt empty target in for BCM calibration.
89096 09/28/04 08:15 cdaq Beam Time Accounting
89095 09/28/04 08:12 cdaq Run 50440: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89094 09/28/04 08:10 cdaq Run 50439: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89093 09/28/04 07:52 Holt target checklist
89092 09/28/04 07:51 Holt target checklist
89091 09/28/04 07:40 cdaq Run 50438: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89090 09/28/04 07:30 cdaq Run 50437: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89089 09/28/04 06:54 cseely equipment checklist scans
89088 09/28/04 06:46 cdaq Run 50436: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89087 09/28/04 06:43 trojer target checklist
89086 09/28/04 06:42 trojer
89085 09/28/04 06:42 trojer Target changed He4->He3
89084 09/28/04 06:37 cseely HMS alcohol bubbler level looks low
89083 09/28/04 06:36 cseely bpm and bcm screenshots
89082 09/28/04 06:11 cdaq Run 50435: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He3
89081 09/28/04 06:07 tro
89080 09/28/04 05:26 cdaq Run 50434: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He4
89079 09/28/04 04:58 cdaq Run 50433: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89078 09/28/04 04:24 cdaq Run 50432: Production run, HMS 40.0 deg, -1.56 GeV, SOS 50 deg, P=+1.70 Target: He4
89077 09/28/04 03:31 cdaq Run 50431: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89076 09/28/04 03:07 trojer Target changed He3->empty->He4
89075 09/28/04 03:05 cdaq Run 50430: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89074 09/28/04 03:04 trojer
89073 09/28/04 02:37 cdaq Run 50429: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89072 09/28/04 02:07 cdaq Run 50428: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89071 09/28/04 00:57 cdaq Run 50427: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89070 09/28/04 00:56 cdaq Run 50426: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89069 09/28/04 00:47 cseely new He(e,e'p)H missing mass plots
89068 09/28/04 00:40 cdaq Run 50425: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89067 09/28/04 00:27 cdaq Run 50424: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He4
89066 09/28/04 00:09 trojer target checklist
89065 09/28/04 00:06 cdaq Beam Time Accounting
89064 09/28/04 00:05 Bosted Shift Summary
Monday
89063 09/27/04 22:45 cdaq Run 50423: BCM Calibration, empty target
89062 09/27/04 22:01 cdaq Run 50422: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He3
89061 09/27/04 20:59 cdaq Run 50421: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He3
89060 09/27/04 19:54 cdaq Run 50420: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He3
89059 09/27/04 19:22 cdaq Run 50419: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He3
89058 09/27/04 19:10 Segbefia He4 pressure
89057 09/27/04 18:22 cdaq Run 50418: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He3
89056 09/27/04 17:49 gaskell SOS pipre disabled for part of run 50417
89055 09/27/04 17:20 gaskell Put sos pipre back to original configuration
89054 09/27/04 17:19 cdaq Run 50417: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He3
89053 09/27/04 17:09 fomin He3 target unparked and moved into the beam position
89052 09/27/04 16:46 cdaq Run 50416: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.70 Target: He3
89051 09/27/04 16:39 gaskell swapped gate generators for SOS pipre
89050 09/27/04 15:59 cdaq Beam Time Accounting
89049 09/27/04 15:57 Keppel Shift Summary
89048 09/27/04 14:17 cdaq Run 50415: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.370 Target: dummy
89047 09/27/04 14:12 cdaq Run 50414: Production run, HMS 40.0 deg, -1.82 GeV, SOS 50 deg, P=+1.370 Target: dummy
89046 09/27/04 13:44 M Jones Hall C Beam Energy Measurement
89045 09/27/04 11:57 Tvaskis Dead fan in loop 1
89044 09/27/04 11:56 Keppel target change
89043 09/27/04 11:52 Tvaskis Changed from He3 to Dummy
89042 09/27/04 11:41 cdaq Run 50413: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.36 Target: dummy
89041 09/27/04 11:18 gaskell HMS dipole setting procedure - use USER Mode
89040 09/27/04 10:55 cdaq Run 50412: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.36 Target: He3
89039 09/27/04 09:50 cdaq Run 50411: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.36 Target: He3
89038 09/27/04 08:46 cdaq Run 50410: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.36 Target: He3
89037 09/27/04 08:42 cdaq Run 50409: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.36 Target: He3
89036 09/27/04 08:01 cdaq Beam Time Accounting
89035 09/27/04 07:55 cseely owl shift summary
89034 09/27/04 07:17 cdaq Run 50408: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.17 Target: He3
89033 09/27/04 06:17 cdaq Run 50407: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.17 Target: He3
89032 09/27/04 05:12 cdaq Run 50406: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.00 Target: He3
89031 09/27/04 04:42 mbukhari BCM and BPM Screens
89030 09/27/04 04:06 cdaq Run 50405: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.00 Target: He3
89029 09/27/04 02:54 cdaq Run 50404: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+0.86 Target: He3
89028 09/27/04 01:55 cdaq Run 50403: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+0.86 Target: He3
89027 09/27/04 01:36 cdaq Run 50402: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=degaussing Target: He4
89026 09/27/04 01:24 trojer target checklist
89025 09/27/04 01:02 cseely Y bpm plots look funny
89024 09/27/04 00:37 cdaq Run 50401: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.59 Target: He4
89023 09/27/04 00:14 trojer Target changed
89022 09/27/04 00:02 cdaq Beam Time Accounting
89021 09/27/04 00:00 fomin Swing shift summary
Sunday
89020 09/26/04 23:27 cdaq Run 50400: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.59 Target: He3
89019 09/26/04 23:00 cdaq Run 50399: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.59 Target: He3
89018 09/26/04 21:58 cdaq Run 50398: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.59 Target: He4
89017 09/26/04 21:35 cdaq Run 50397: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.59 Target: He4
89016 09/26/04 20:29 cdaq Run 50396: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.36 Target: He4
89015 09/26/04 19:30 cdaq Run 50395: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.17 Target: He4
89014 09/26/04 18:26 cdaq Run 50394: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.00 Target: He4
89013 09/26/04 17:29 cdaq Run 50393: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+0.86 Target: He4
89012 09/26/04 17:23 cdaq Run 50392: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+0.86 Target: He4
89011 09/26/04 16:59 cdaq Run 50391: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.70 Target: He4
89010 09/26/04 16:04 tajima day shift summary
89009 09/26/04 16:01 cdaq Beam Time Accounting
89008 09/26/04 15:57 cdaq Run 50390: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.70 Target: He4
89007 09/26/04 15:45 tajima the dipole control computer rebooted
89006 09/26/04 15:03 tajima configuration change done
89005 09/26/04 14:55 cdaq Run 50389: Production run, HMS 40.0 deg, -2.13 GeV, SOS 50 deg, P=+1.70 Target: He4
89004 09/26/04 13:16 cdaq Run 50388: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He4
89003 09/26/04 12:39 tajima note on run 50387
89002 09/26/04 12:15 cdaq Run 50387: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He4
89001 09/26/04 12:02 mack crate voltages okay at the moment
89000 09/26/04 11:07 Tvaskis Change Target
88999 09/26/04 11:02 cdaq Run 50386: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He4
88998 09/26/04 10:18 gaskell SOS pipre
88997 09/26/04 09:52 tajima Testing SOS trigger
88996 09/26/04 09:31 cdaq Run 50385: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88995 09/26/04 09:26 cdaq Run 50384: Production and TEST run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88994 09/26/04 09:21 gaskell Target: Loop 1 fan died and came back
88993 09/26/04 09:20 cdaq Run 50383: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88992 09/26/04 08:23 cseely shift summary
88991 09/26/04 08:19 cdaq Run 50382: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88990 09/26/04 08:15 gaskell HMS drift chambers tripped at end of run 50381
88989 09/26/04 08:07 cdaq Beam Time Accounting
88988 09/26/04 08:07 cseely shift summary
88987 09/26/04 07:33 cdaq Run 50381: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88986 09/26/04 06:39 cdaq Run 50380: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88985 09/26/04 06:24 mbukhari BCM and BPM Screens
88984 09/26/04 05:36 cdaq Run 50379: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88983 09/26/04 04:51 cdaq Run 50378: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88982 09/26/04 04:45 cseely changed to He3 from dummy target
88981 09/26/04 04:12 cdaq Run 50377: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.70 Target: He3
88980 09/26/04 04:04 cseely SCAL channel counting low
88979 09/26/04 04:00 mbukhari target checklist after move
88978 09/26/04 03:40 cdaq Run 50376: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.26 Target: Al_Dummy
88977 09/26/04 03:36 mbukhari Target movement: 3He -> Al Dummy
88976 09/26/04 03:16 cseely He(e,e'p)H "elastics" followup
88975 09/26/04 02:12 cdaq Run 50375: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.26 Target: He3
88974 09/26/04 01:57 cseely modified target masses in gtarg.param file
88973 09/26/04 01:12 cdaq Run 50374: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.26 Target: He3
88972 09/26/04 01:10 cdaq Run 50373: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.26 Target: He3
88971 09/26/04 00:15 Vipuli target checklist
88970 09/26/04 00:08 cdaq Run 50372: Production run, HMS 40.0 deg, -2.48 GeV, SOS 40 deg, P=+1.26 Target: He3
88969 09/26/04 00:01 cdaq Beam Time Accounting
Saturday
88968 09/25/04 23:57 Bosted Shift Summary
88967 09/25/04 23:44 cdaq Run 50371: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He3
88966 09/25/04 22:42 Vipuli Taget GUI after changing target
88965 09/25/04 22:40 cdaq Run 50370: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He3
88964 09/25/04 22:39 Bosted Q2 trip: end of run 50369 bad
88963 09/25/04 22:07 cdaq Run 50369: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He3
88962 09/25/04 21:50 Vipuli Target changed
88961 09/25/04 21:49 cdaq Run 50368: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He3
88960 09/25/04 21:32 mack offsets are rock solid, must be a gain shift; I'll be in Sunday morning
88959 09/25/04 21:26 Bosted Momentum changed both spectrometers. Run 50364 good fro HMS only
88958 09/25/04 20:44 mack offsets are rock solid, must be a gain shift
88957 09/25/04 20:36 cdaq Run 50367: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He4
88956 09/25/04 19:32 cdaq Run 50366: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He4
88955 09/25/04 19:03 gaskell BCMs not stable
88954 09/25/04 18:38 Vipuli target checklist
88953 09/25/04 18:29 cdaq Run 50365: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He4
88952 09/25/04 18:26 cdaq Run 50364: Production run, HMS 40.0 deg, -248 GeV, SOS 40 deg, P=+1.26 Target: He4
88951 09/25/04 17:19 cdaq Run 50363: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He4
88950 09/25/04 17:06 Vipuli Target reboot
88949 09/25/04 17:01 cdaq Run 50362: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He4
88948 09/25/04 16:34 cdaq Run 50361: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He4
88947 09/25/04 16:08 tajima shift summary
88946 09/25/04 16:04 cdaq Beam Time Accounting
88945 09/25/04 15:45 adaniel shift check list
88944 09/25/04 15:30 cdaq Run 50360: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He4
88943 09/25/04 14:31 cdaq Run 50359: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He4
88942 09/25/04 14:31 Hill Moved to He4 from He3
88941 09/25/04 13:09 tajima Runs 50356 and 50357
88940 09/25/04 13:01 cdaq Run 50358: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He3
88939 09/25/04 12:45 tajima Run #50356 -- Short run
88938 09/25/04 12:43 cdaq Run 50357: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He3
88937 09/25/04 12:23 cdaq Run 50356: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He3
88936 09/25/04 11:26 cdaq Run 50355: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He3
88935 09/25/04 10:25 cdaq Run 50354: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He3
88934 09/25/04 09:26 cdaq Run 50353: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He3
88933 09/25/04 09:12 Donal Format the entry
88932 09/25/04 08:25 cdaq Run 50352: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: He3
88931 09/25/04 08:17 Hill Moved to He3 from Dummy
88930 09/25/04 08:11 mbukhari shift summary
88929 09/25/04 08:08 cdaq Beam Time Accounting
88928 09/25/04 07:50 cdaq Run 50351: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: dummy
88927 09/25/04 07:18 mbukhari SOS Momentunm change
88926 09/25/04 07:18 mbukhari SOS Momentunm change
88925 09/25/04 07:17 cdaq Run 50350: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: dummy
88924 09/25/04 07:13 cdaq Run 50349: Production run, SOS at 40deg, -1.70, HMS at 40.0 deg, HMS at -2.90, Target: dummy
88923 09/25/04 06:42 slifer target motion
88922 09/25/04 06:35 cdaq Run 50348: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: Dummy
88921 09/25/04 05:47 cdaq Run 50347: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He3
88920 09/25/04 05:22 mbukhari Run Replays: Histograms Different for Run 50344
88919 09/25/04 05:08 slifer target screen
88918 09/25/04 04:59 slifer target screen
88917 09/25/04 04:52 mbukhari BCM and BPM Screens
88916 09/25/04 04:44 cdaq Run 50346: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He3
88915 09/25/04 03:40 cdaq Run 50345: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He3
88914 09/25/04 02:31 cdaq Run 50344: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He3
88913 09/25/04 01:36 mbukhari Run #50342 is JUNK
88912 09/25/04 01:36 mbukhari Drift Chambers G1 & G2 Tripped
88911 09/25/04 01:33 cdaq Run 50343: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He3
88910 09/25/04 01:26 cdaq Run 50342: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He3
88909 09/25/04 01:18 mbukhari HMS Q1 MPS Overtemp Interlock
88908 09/25/04 00:45 slifer correction
88907 09/25/04 00:39 slifer target motion
88906 09/25/04 00:38 cdaq Run 50341: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He3
88905 09/25/04 00:16 cseely Shift Summary
88904 09/25/04 00:01 cdaq Beam Time Accounting
Friday
88903 09/24/04 23:41 cdaq Run 50340: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88902 09/24/04 22:35 cseely bpms and bcms
88901 09/24/04 22:34 cseely
88900 09/24/04 22:29 cdaq Run 50339: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88899 09/24/04 21:25 cdaq Run 50338: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88898 09/24/04 19:26 cdaq Run 50337: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88897 09/24/04 19:07 cdaq Run 50336: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88896 09/24/04 19:06 cdaq Run 50335: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88895 09/24/04 19:04 cdaq Run 50334: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88894 09/24/04 19:02 cdaq Run 50333: Production run, SOS at 40deg, -1.26, HMS at 40.0 deg, HMS at -2.90, Target: He4
88893 09/24/04 19:00 hill HMS Dipole interlock while setting
88892 09/24/04 18:56 fomin target moved from C3% to He4
88891 09/24/04 18:33 hill HMS Dipole interlock while setting
88890 09/24/04 18:27 cseely HMS Dipole interlock while setting
88889 09/24/04 18:04 cdaq Run 50332: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -2.71, Target: C-3
88888 09/24/04 18:03 cdaq Run 50331: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -2.71, Target: C-3
88887 09/24/04 17:51 fomin target moved from He4 to C3%
88886 09/24/04 17:16 cdaq Run 50330: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.17, Target: He4
88885 09/24/04 17:12 fomin target moved from Al Dummy to He4
88884 09/24/04 16:53 fomin He3 target parked, He4 unparked
88883 09/24/04 16:42 cdaq Run 50329: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.17, Target: Al Dummy
88882 09/24/04 16:41 fomin Target moved from He3 to Al Dummy
88881 09/24/04 16:06 cdaq Run 50328: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.17, Target: He3
88880 09/24/04 16:03 Keppel target change
88879 09/24/04 16:02 cdaq Beam Time Accounting
88878 09/24/04 16:00 Potterveld Day shift summary
88877 09/24/04 15:41 cdaq Run 50327: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.17, Target: C-3
88876 09/24/04 15:39 cdaq Run 50326: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.17, Target: C-3
88875 09/24/04 15:29 Keppel target checklist
88874 09/24/04 15:13 cdaq Run 50325: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.17, Target: C-3
88873 09/24/04 13:39 cdaq Run 50324: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: C-3
88872 09/24/04 12:57 cdaq Run 50323: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: C-3
88871 09/24/04 12:54 cdaq Run 50322: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: C-3
88870 09/24/04 12:53 Keppel target change
88868 09/24/04 12:09 cdaq Run 50321: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He3
88867 09/24/04 11:58 Potterveld SOS magnet excitation data
88866 09/24/04 11:41 cdaq Run 50320: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He3
88863 09/24/04 10:58 cdaq Run 50319: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He3
88862 09/24/04 09:44 cdaq Run 50318: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He3
88861 09/24/04 08:46 mbukhari Shift Summary
88860 09/24/04 08:31 cdaq Run 50317: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He3
88859 09/24/04 08:03 cdaq Beam Time Accounting
88858 09/24/04 07:26 cdaq Run 50316: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He3
88857 09/24/04 07:11 mbukhari 4He runs complete for the shift
88856 09/24/04 07:10 McKee Betabrite restarted
88855 09/24/04 07:10 mbukhari shift checklist scans
88854 09/24/04 07:10 mbukhari shift checklist scans
88853 09/24/04 06:39 mbukhari bcm and bpm screens
88852 09/24/04 06:00 McKee target: move to he3 target
88851 09/24/04 05:59 cdaq Run 50315: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He3
88850 09/24/04 05:55 cdaq Run 50314: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He4
88849 09/24/04 05:19 McKee target checklist
88848 09/24/04 05:06 cdaq Run 50313: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He4
88847 09/24/04 04:23 McKee target: jeffylab rebooted
88846 09/24/04 03:58 cdaq Run 50312: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He4
88845 09/24/04 02:07 cdaq Run 50311: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He4
88844 09/24/04 01:06 McKee beam on he4 target
88843 09/24/04 01:06 cdaq Run 50310: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He4
88842 09/24/04 00:35 fomin HMS dipole field control errors
88841 09/24/04 00:13 cdaq Run 50309: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He4
88840 09/24/04 00:07 cdaq Beam Time Accounting
Thursday
88839 09/23/04 23:49 cseely some missing mass plots
88838 09/23/04 23:48 fomin Swing shift summary
88837 09/23/04 23:42 cdaq Run 50308: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: He4
88836 09/23/04 23:41 cseely moved to He4 from dummy
88835 09/23/04 23:05 cdaq Run 50307: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, HMS at -3.7, Target: Al Dummy
88834 09/23/04 23:01 gaskell Dipole set
88833 09/23/04 22:45 gaskell Usable BCM calibration run
88832 09/23/04 22:38 fomin MPS error, NMR error on the HMS dipole
88831 09/23/04 22:29 gaskell HMS dipole again
88830 09/23/04 22:14 gaskell more HMS dipole
88829 09/23/04 22:01 gaskell HMS dipole troubles
88828 09/23/04 21:09 cdaq Run 50306: BCM Calibration
88827 09/23/04 20:29 cdaq Run 50305: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: Al Dummy
88826 09/23/04 20:01 fomin bcm and bpm screens
88824 09/23/04 19:25 cseely moved to dummy from He4
88823 09/23/04 18:54 cdaq Run 50304: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He4
88822 09/23/04 18:44 cdaq Run 50303: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He4
88821 09/23/04 17:52 gaskell C luminosity scan results
88820 09/23/04 17:46 gaskell He3 Luminosity Scan Results
88819 09/23/04 17:43 cdaq Run 50302: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He4
88818 09/23/04 17:40 gaskell axis labels wrong
88817 09/23/04 17:37 gaskell He4 luminosity scan (preliminary) results
88816 09/23/04 17:23 Potterveld Day shift summary
88815 09/23/04 17:18 cseely restarted target gui
88814 09/23/04 17:01 fomin HMS dipole field control error
88813 09/23/04 16:58 cseely target checklist
88812 09/23/04 16:43 cdaq Run 50301: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He4
88811 09/23/04 16:36 fomin HMS dipole field control error
88810 09/23/04 16:30 fomin GAS system interlock low psi alarm
88809 09/23/04 16:27 cseely Loop2 temperature alarm (
88808 09/23/04 16:24 fomin HMS dipole field control error
88807 09/23/04 16:04 cdaq Beam Time Accounting
88806 09/23/04 15:54 okayasu Target changed
88805 09/23/04 15:53 cdaq Run 50300: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He4
88804 09/23/04 15:15 fomin shift checklist ending on 9/22
88803 09/23/04 15:03 cdaq Run 50299: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88802 09/23/04 14:03 cdaq Run 50298: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88801 09/23/04 13:53 okayasu Target changed.
88800 09/23/04 10:31 cdaq Run 50297: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88799 09/23/04 10:28 saw Updated echmsq3i_set_s
88798 09/23/04 10:11 okayasu `Target temporaly moved
88797 09/23/04 10:07 gaskell One more HMS dipole field control error
88796 09/23/04 09:24 cdaq Run 50296: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88795 09/23/04 09:23 gaskell another HMS dipole field control error
88794 09/23/04 09:16 cdaq Run 50295: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88793 09/23/04 09:08 cdaq Run 50294: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88792 09/23/04 09:04 gaskell HMS dipole field control error
88791 09/23/04 08:08 cdaq Run 50293: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88790 09/23/04 08:00 cdaq Beam Time Accounting
88789 09/23/04 07:57 jroche owl shift summary : no beam
88788 09/23/04 07:25 trojer target checklist
88787 09/23/04 07:06 jroche beam finally
88786 09/23/04 07:02 cdaq Run 50292: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88785 09/23/04 06:32 mbukhari Helium supply replenished
88784 09/23/04 00:29 trojer Rebooted target GUI
88783 09/23/04 00:07 Donal Shift report
88782 09/23/04 00:04 cdaq Beam Time Accounting
Wednesday
88781 09/22/04 23:26 cseely moved to He3 from empty
88780 09/22/04 23:18 cdaq Run 50291: Production run, SOS at 50deg, -1.7, HMS at 26.0 deg, -4.32 Target: He3
88779 09/22/04 23:14 cdaq Run 50290: premature run start
88778 09/22/04 22:55 fomin bcm calibration update (attn: Dave Mack)
88777 09/22/04 22:51 fomin bcm and bpm screens
88776 09/22/04 22:45 cdaq Run 50289: BCM Calibration
88774 09/22/04 22:15 cseely vesda alarm in zone 4 - reset
88773 09/22/04 22:09 fomin scanner doesn't work
88771 09/22/04 21:45 cdaq Run 50288: BCM Calibration
88770 09/22/04 21:29 cdaq Run 50287: Junk, checking to see if the angle snapshot thingie works properly now that we've rebooted cdaql1.
88769 09/22/04 21:26 fomin SOS angle snapshot and cdaql1 boot problem
88768 09/22/04 21:21 cdaq Run 50286: Junk, checking to see if the angle snapshot thingie works properly now that we've rebooted cdaql1.
88767 09/22/04 20:36 fomin HMS dipole ramp up errors
88766 09/22/04 20:14 cseely empty target in. BCM calibration has commenced.
88765 09/22/04 20:13 cdaq Run 50285: BCM calibration , target: empty
88764 09/22/04 20:00 cdaq Run 50284: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: C3%
88763 09/22/04 19:51 target screen at 94uA (during He3 Lumi. scan)
88762 09/22/04 19:51 target screen at 94uA (during He3 Lumi. scan)
88761 09/22/04 19:47 cdaq Run 50283: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He3
88760 09/22/04 19:40 cseely target screen at 81uA (during He3 Lumi. scan)
88759 09/22/04 19:38 cdaq Run 50282: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He3
88758 09/22/04 19:29 cdaq Run 50281: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: C3%
88757 09/22/04 19:24 cdaq Run 50280: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: C3%
88756 09/22/04 19:23 cdaq Run 50279: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: C3%
88755 09/22/04 19:21 cseely moved to C(3%) from He3
88754 09/22/04 19:15 cseely target screen at 67uA (during He3 Lumi. scan)
88753 09/22/04 19:14 cseely target screen at 50uA (during He3 Lumi. scan)
88752 09/22/04 19:10 cdaq Run 50278: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He3
88751 09/22/04 19:08 cseely target screen at 31uA (during He3 Lumi. scan)
88750 09/22/04 19:02 cdaq Run 50277: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He3
88749 09/22/04 18:53 cdaq Run 50276: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: C3%
88748 09/22/04 18:46 cdaq Run 50275: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: C3%
88747 09/22/04 18:42 cseely moved to C(3%) from He3
88746 09/22/04 18:34 cseely target screen at 31uA (during He3 Lumi. scan)
88745 09/22/04 18:34 cdaq Run 50274: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target:He3
88744 09/22/04 18:28 cseely target screen at 16uA (during He3 Lumi. scan)
88743 09/22/04 18:27 cdaq Run 50273: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target:He3
88742 09/22/04 18:26 cseely Loop1 parked, Loop2 unparked. Moved from C(3%) to He3(Loop2)
88741 09/22/04 18:16 cdaq Run 50272: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: C3%
88740 09/22/04 18:12 cseely target change TO: C(3%) from He4(Loop1)
88739 09/22/04 18:06 cdaq Run 50271: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88738 09/22/04 17:59 cdaq Run 50270: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88737 09/22/04 17:53 cdaq Run 50269: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88736 09/22/04 17:52 cseely target screenshot at 91 uA (lumi. scan)
88735 09/22/04 17:48 cseely target screenshot at 82 uA (lumi. scan)
88734 09/22/04 17:47 cdaq Run 50268: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88733 09/22/04 17:40 cseely target screenshot at 62 uA (lumi. scan)
88732 09/22/04 17:39 cdaq Run 50267: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88731 09/22/04 17:34 cseely target screenshot at 47 uA (lumi. scan)
88730 09/22/04 17:32 cdaq Run 50266: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88729 09/22/04 17:29 cseely target screenshot at 32 uA (lumi. scan)
88728 09/22/04 17:27 cdaq Run 50265: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88727 09/22/04 17:16 cdaq Run 50264: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88726 09/22/04 17:15 cdaq Run 50263: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88725 09/22/04 17:13 cdaq Run 50262: Production run, SOS at 30deg, -1.7, HMS at 18.0 deg, -3.59, Target: He4
88724 09/22/04 17:04 cseely target screen at 15uA (during He4 Lumi. scan)
88723 09/22/04 16:39 Potterveld Day shift summary
88722 09/22/04 16:28 cseely HMS dipole crash #2
88721 09/22/04 16:25 cdaq Beam Time Accounting
88720 09/22/04 16:17 Potterveld setting up for luminosity scan
88719 09/22/04 16:02 cseely target checklist
88718 09/22/04 16:00 okayasu Target changed to empty for harp run
88717 09/22/04 15:28 okayasu Screenshot
88716 09/22/04 15:18 cdaq Run 50261: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He4
88715 09/22/04 14:14 cdaq Run 50260: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He4
88714 09/22/04 13:13 cdaq Run 50259: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He4
88713 09/22/04 12:09 cdaq Run 50258: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He4
88712 09/22/04 11:21 okayasu Target changed
88711 09/22/04 11:08 cdaq Run 50257: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He4
88710 09/22/04 10:04 smithg Loop1 target fan story
88709 09/22/04 09:51 okayasu Coolant flow meter alart
88708 09/22/04 09:50 cdaq Run 50256: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88707 09/22/04 09:36 okayasu Temprature limit was changed.
88706 09/22/04 09:24 cdaq Run 50255: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88705 09/22/04 09:21 okayasu IOC Cryotarget rebooted
88704 09/22/04 08:47 horn Owl Shift Summary
88703 09/22/04 08:18 cdaq Beam Time Accounting
88702 09/22/04 07:58 trojer target checklist
88701 09/22/04 07:12 cdaq Run 50254: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88700 09/22/04 07:08 cdaq Run 50253: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88699 09/22/04 07:06 cdaq Run 50252: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88698 09/22/04 05:57 cdaq Run 50251: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88697 09/22/04 05:44 mbukhari BPM and BCM log checklist item
88696 09/22/04 05:23 cdaq Run 50250: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88695 09/22/04 04:23 cdaq Run 50249: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88694 09/22/04 04:14 cdaq Run 50248: daq test
88693 09/22/04 04:07 cdaq Run 50247: daq test
88692 09/22/04 03:53 cdaq Run 50246: daq test
88691 09/22/04 03:50 cdaq Run 50245: daq test
88690 09/22/04 03:44 cdaq Run 50244: daq test
88689 09/22/04 03:38 cdaq Run 50243: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88688 09/22/04 03:25 cdaq Run 50242: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88687 09/22/04 03:21 cdaq Run 50241: Production run, SOS at 50. deg, -1.7, HMS at 26.0 deg, -4.32, Target: He3
88686 09/22/04 02:27 cdaq Run 50240: Production run, SOS at 50. deg, -1.7
88685 09/22/04 01:26 cdaq Run 50239: Production run, SOS at 50. deg, -1.7
88684 09/22/04 01:21 horn Run 50237 junk
88683 09/22/04 00:59 cdaq Run 50238: Production run, SOS at 50. deg, -1.7
88682 09/22/04 00:28 cdaq Run 50237: Production run, SOS at 50. deg, -1.7
88681 09/22/04 00:26 trojer moved to He3 target (Loop 2)
88680 09/22/04 00:06 Donal Shift Report
88679 09/22/04 00:03 cdaq Beam Time Accounting
Tuesday
88678 09/21/04 23:54 cdaq Run 50236: Production run, SOS at 50. deg, -1.7
88677 09/21/04 23:38 cseely Rebooted target IOC - Loop1 fan did not come back
88676 09/21/04 23:08 cseely cleared another fan speed alarm (lo 0) and vent pressure (hihi) alarms
88675 09/21/04 22:55 cdaq Run 50235: Production run, SOS at 50. deg, -1.7
88674 09/21/04 22:51 cseely moved to dummy target
88673 09/21/04 22:41 tajima bpm and bcm screens
88672 09/21/04 22:14 cdaq Run 50234: Production run, SOS at 50. deg, -1.7
88671 09/21/04 21:12 cdaq Run 50233: Production run, SOS at 50. deg, -1.7
88670 09/21/04 20:29 cseely Loop 1 fan control screen shot
88669 09/21/04 20:26 cseely Loop1 fan tachometer reading 0
88668 09/21/04 20:17 cdaq Run 50232: Production run, SOS at 50. deg, -1.7
88667 09/21/04 18:37 cseely parked Loop1 and unparked Loop2, moved to Loop2
88666 09/21/04 17:58 cdaq Run 50231: Production run, SOS at 44.79 deg, +1.74, HMS at 16.13 deg, -4.653
88665 09/21/04 17:53 cdaq Run 50230: Production run, SOS at 44.79 deg, +1.74, HMS at 16.13 deg, -4.653
88664 09/21/04 17:47 cdaq Run 50229: Production run, SOS at 44.79 deg, +1.74, HMS at 16.13 deg, -4.653
88663 09/21/04 17:42 cdaq Run 50228: Production run, SOS at 45.17 deg, +1.74, HMS at 16.13 deg, -4.653
88662 09/21/04 17:42 Donal HNS dipole
88661 09/21/04 17:23 smithg new 4He target PID params & current limit
88660 09/21/04 17:12 cseely target checklist
88659 09/21/04 17:00 Potterveld Day shift summary
88658 09/21/04 16:46 gaskell HMS dipole field control errors
88657 09/21/04 16:44 gaskell run 50227 is junk
88656 09/21/04 16:40 cdaq Run 50227: Production run, SOS at 44.79 deg, +1.74, HMS at 16.13 deg, -4.653
88655 09/21/04 16:12 fomin target moved from He3 to He4
88654 09/21/04 16:11 cdaq Beam Time Accounting
88653 09/21/04 16:10 fomin target parking/unparking
88652 09/21/04 15:40 cdaq Run 50226: Production run, SOS at 44.79 deg, +1.74, HMS at 16.13 deg, -4.653
88651 09/21/04 15:36 cdaq Run 50225: Production run, SOS at 44.79 deg, +1.74, HMS at 16.13 deg, -4.653
88650 09/21/04 14:43 cdaq Run 50224: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88649 09/21/04 14:32 fomin target alarm loop1
88648 09/21/04 14:29 smithg Improved 3He PID parameters
88647 09/21/04 14:27 cdaq Run 50223: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88646 09/21/04 13:34 cdaq Run 50222: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88645 09/21/04 12:22 cdaq Run 50221: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88644 09/21/04 12:20 cdaq Run 50220: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88643 09/21/04 12:02 cdaq Run 50219: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88642 09/21/04 11:51 fomin target checklist
88641 09/21/04 11:32 smithg 4He target leak isolated
88640 09/21/04 11:31 cdaq Run 50218: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88639 09/21/04 10:59 Lassiter Q2 trim coil
88638 09/21/04 10:57 beaufait target supervisor
88637 09/21/04 10:38 saw, ckeith Variables added to target logger
88636 09/21/04 09:49 adaniel trim coil quench hms q2
88635 09/21/04 08:33 horn Owl Shift Summary
88634 09/21/04 08:18 cdaq Beam Time Accounting
88633 09/21/04 08:15 cdaq Run 50217: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88632 09/21/04 07:58 cdaq Run 50216: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88631 09/21/04 07:46 cdaq Run 50215: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88630 09/21/04 07:37 cdaq Run 50214: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88629 09/21/04 07:27 cdaq Run 50213: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88628 09/21/04 07:12 cdaq Run 50212: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88627 09/21/04 07:00 cdaq Run 50211: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88626 09/21/04 06:49 cdaq Run 50210: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88625 09/21/04 06:39 cdaq Run 50209: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88624 09/21/04 06:05 cdaq Run 50208: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88623 09/21/04 05:50 cdaq Run 50207: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88622 09/21/04 05:38 cdaq Run 50206: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88621 09/21/04 05:23 cdaq Run 50205: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88620 09/21/04 04:40 trojer He4 pressure fallup, reached LOLO Limit
88619 09/21/04 04:38 horn Frequent TS power cycling
88618 09/21/04 04:35 cdaq Run 50204: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88617 09/21/04 04:23 cdaq Run 50203: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88616 09/21/04 04:09 cdaq Run 50202: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88615 09/21/04 03:50 cdaq Run 50201: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88614 09/21/04 03:26 cdaq Run 50200: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88613 09/21/04 03:20 cdaq Run 50198: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88612 09/21/04 03:00 trojer He4 pressure fallup
88611 09/21/04 02:29 horn TS dead again at end of run 50196
88610 09/21/04 02:18 trojer target checklist
88609 09/21/04 02:16 cdaq Run 50197: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88608 09/21/04 01:33 cdaq Run 50196: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.653
88607 09/21/04 00:17 horn Rebooted trigger supervisor
88606 09/21/04 00:05 cdaq Beam Time Accounting
Monday
88605 09/20/04 23:59 Bosted Shift summary
88604 09/20/04 23:50 Donal He4 pressure fallup
88603 09/20/04 23:21 Donal Target motion - Al Dummy to He3
88602 09/20/04 22:41 Donal He4 pressure
88601 09/20/04 22:39 cdaq Run 50194: Production run, SOS at 50 deg, -1.70, HMS at 22 deg, -4.653
88600 09/20/04 20:49 Donal He4 pressure
88599 09/20/04 20:30 cdaq Run 50193: DAQ test - cosmics
88598 09/20/04 20:26 gaskell Revenge of the trigger supervisor
88597 09/20/04 19:27 gaskell Q2 fix
88596 09/20/04 19:17 Donal Cell pressure Loop 1
88595 09/20/04 19:06 Donal target checklist
88594 09/20/04 18:57 Donal He4 target
88593 09/20/04 17:57 smithg both 4he and 3he available now
88592 09/20/04 17:36 gaskell target PID
88591 09/20/04 16:22 Lung day shift summary
88590 09/20/04 16:17 cdaq Beam Time Accounting
88589 09/20/04 14:48 lassiter HMS Quads ramprate to 1.00 A/s
88587 09/20/04 14:03 smithg target leaking after all
88585 09/20/04 12:54 smithg loop1 (4He) update
88584 09/20/04 11:38 Lung Restricted Access
88583 09/20/04 11:34 gaskell Electronics room air conditioning
88582 09/20/04 11:31 gaskell new sos angle vernier adjustment
88581 09/20/04 11:28 gaskell SOS cer 3
88580 09/20/04 10:28 mack BCM calibration
88579 09/20/04 08:48 horn Owl Shift Summary
88578 09/20/04 07:28 cdaq Run 50191: Production run, SOS at 50 deg, +1.70, HMS at 22 deg, -4.70
88577 09/20/04 06:47 mb Shift checklist scan
88576 09/20/04 04:55 cdaq Run 50190: Production run, SOS at 50 deg, -1.70, HMS at 18 deg, -5.10
88575 09/20/04 03:55 cdaq Run 50189: Production run, SOS at 50 deg, -1.70, HMS at 18 deg, -5.10
88574 09/20/04 03:07 cdaq Run 50188: Production run, SOS at 50 deg, -1.70, HMS at 18 deg, -5.10
88573 09/20/04 03:02 trojer target checklist
88572 09/20/04 02:24 cdaq Run 50187: Production run, SOS at 50 deg, -1.70, HMS at 18 deg, -5.10
88571 09/20/04 00:02 Donal Shift summary
Sunday
88570 09/19/04 23:55 cdaq Run 50186: Production run, SOS at 50 deg, -1.59, HMS at 32 deg, -3.13
88569 09/19/04 23:06 cdaq Run 50185: Production run, SOS at 50 deg, -1.59, HMS at 32 deg, -3.13
88568 09/19/04 22:02 cdaq Run 50184: Production run, SOS at 50 deg, -1.59, HMS at 32 deg, -3.13
88567 09/19/04 21:31 cdaq Run 50183: Production run, SOS at 50 deg, -1.36, HMS at 32 deg, -3.13
88566 09/19/04 20:55 cseely bpm and bcm screens
88565 09/19/04 20:51 cseely target checklist
88564 09/19/04 20:51 gaskell He3 target response to beam trips
88563 09/19/04 20:09 cdaq Run 50182: Production run, SOS at 50 deg, -1.36, HMS at 32 deg, -3.13
88562 09/19/04 19:22 gaskell BCM calibration run
88561 09/19/04 19:22 cdaq Run 50181: Production run, SOS at 50 deg, -1.36, HMS at 32 deg, -3.13
88560 09/19/04 19:18 gaskell added Helium target info to epics dictionary
88559 09/19/04 18:38 cdaq Run 50180: BCM calibration (changing SOS momentum before/during run)
88558 09/19/04 18:23 cdaq Run 50179: BCM calibration (changing SOS momentum before/during run)
88557 09/19/04 17:10 cdaq Run 50178: Production run
88556 09/19/04 16:13 cdaq Run 50177: Production run
88555 09/19/04 16:01 ioana Shift summary
88554 09/19/04 15:17 cdaq Run 50176: Production run
88553 09/19/04 14:35 cdaq Run 50175: Production run
88552 09/19/04 13:58 cdaq Run 50174: Production run SOS at 50 deg, -0.86, HMS at 32 deg, -3.13 Target: He3 ps1=1 ps2=10 ps3=99999 Trigger=A .OR. B for HMS, A.OR.B for SOS
88551 09/19/04 13:04 horn Q3 reboot
88550 09/19/04 12:48 gabriel Q3 trip
88549 09/19/04 12:26 cdaq Run 50173: Production run SOS at 50 deg, -0.86, HMS at 32 deg, -3.13 Target: He3 ps1=1 ps2=10 ps3=99999 Trigger=A .OR. B for HMS, A.OR.B for SOS
88548 09/19/04 12:19 johna SOS Trigger timing change!
88547 09/19/04 12:19 cdaq Run 50172: Production run
88546 09/19/04 12:13 cdaq Run 50171: trigger test
88545 09/19/04 12:10 cdaq Run 50170: trigger test
88544 09/19/04 11:50 ioana bpm position screen grab
88543 09/19/04 11:38 horn Target motion - Al Dummy to He3
88542 09/19/04 11:32 cdaq Run 50169: Production run
88541 09/19/04 11:25 gaskell SOS trigger timing
88540 09/19/04 11:06 cdaq Run 50168: Production run
88539 09/19/04 11:04 cdaq Run 50167: Production run
88538 09/19/04 11:00 gaskell changed sos trigger to ELREAL.or.PIPRE
88537 09/19/04 10:29 gaskell Pictures for entry 88536
88536 09/19/04 10:23 gaskell SOS scin tdc timing
88535 09/19/04 10:06 cdaq Run 50166: Production run
88534 09/19/04 10:05 horn Target Motion
88533 09/19/04 09:58 gaskell strange computer dead time
88532 09/19/04 09:25 cdaq Run 50165: Production run - 3He. SOS at 50 deg, +1.59,HMS at 32 deg, -3.65
88531 09/19/04 09:11 cdaq Run 50164: Production run - 3He. SOS at 50 deg, +1.59,HMS at 32 deg, -3.65
88530 09/19/04 08:58 cdaq Run 50163: Production run - 3He. SOS at 50 deg, +1.59,HMS at 32 deg, -3.65
88529 09/19/04 08:56 cdaq Run 50162: Production run - 3He. SOS at 50 deg, +1.59,HMS at 32 deg, -3.65
88528 09/19/04 08:39 cdaq Run 50161: Production run - 3He. SOS at 50 deg, +1.59,HMS at 32 deg, -3.65
88527 09/19/04 08:08 horn Shift checklist scan
88526 09/19/04 07:29 cdaq Run 50160: Production run - 3He. SOS at 50 deg, +1.59,HMS at 32 deg, -3.65
88525 09/19/04 07:28 bradf shift summary
88524 09/19/04 06:27 cdaq Run 50159: Production run - 3He. SOS at 50 deg, +1.36,HMS at 32 deg, -3.65
88523 09/19/04 05:26 cdaq Run 50158: Production run - 3He. SOS at 50 deg, +1.36,HMS at 32 deg, -3.65
88522 09/19/04 05:24 bradf
88521 09/19/04 04:25 bradf beam off
88520 09/19/04 04:20 cdaq Run 50157: Production run - 3He. SOS at 50 deg, +1.17,HMS at 32 deg, -3.65
88519 09/19/04 03:07 cdaq Run 50156: Production run - 3He. SOS at 50 deg, +1.17,HMS at 32 deg, -3.65
88518 09/19/04 02:33 cdaq Run 50155: Production run - 3He. SOS at 50 deg, +1.00,HMS at 32 deg, -3.65
88517 09/19/04 02:29 Trojer target checklist
88516 09/19/04 01:39 cdaq Run 50154: Production run - 3He. SOS at 50 deg, +1.00,HMS at 32 deg, -3.65
88515 09/19/04 00:39 bradf beam loss
88514 09/19/04 00:36 cdaq Run 50153: Production run - 3He. SOS at 50 deg, +1.00,HMS at 32 deg, -3.65
88513 09/19/04 00:02 Donal shift report
Saturday
88512 09/18/04 22:57 cdaq Run 50152: Production run - 3He. SOS at 50 deg, +0.86, HMS at 32 deg, -3.65
88511 09/18/04 22:05 Donal BPM and BCM
88510 09/18/04 21:49 cdaq Run 50151: Production run - 3He. SOS at 50 deg, +0.86, HMS at 32 deg, -3.65
88509 09/18/04 21:42 johna Preliminary target boiling tests for 3He (correct figures this time)
88508 09/18/04 21:41 johna Preliminary target boiling tests for 3He
88507 09/18/04 20:58 cdaq Run 50150: Production run - 3He. SOS at 50 deg, +0.86, HMS at 32 deg, -3.65
88506 09/18/04 20:11 cdaq Run 50149: Luminosity scan - 10 uA
88505 09/18/04 20:03 cdaq Run 50148: Luminosity scan - 20 uA
88504 09/18/04 19:57 cdaq Run 50147: Luminosity scan - 30 uA
88503 09/18/04 19:50 Bosted target checklist
88502 09/18/04 19:48 cdaq Run 50146: Luminosity scan - 40 uA
88501 09/18/04 19:37 cdaq Run 50145: Luminosity scan - 50 uA
88500 09/18/04 19:34 bosted Current scan on 3He
88499 09/18/04 19:29 johna End of run failed - several runs in a row
88498 09/18/04 19:27 cdaq Run 50144: Luminosity scan - 50 uA
88497 09/18/04 19:18 cdaq Run 50143: Luminosity scan - 50 uA
88496 09/18/04 19:11 cdaq Run 50142: Luminosity scan - 40 uA
88495 09/18/04 18:59 cdaq Run 50141: Luminosity scan - 30 uA
88494 09/18/04 18:50 cdaq Run 50140: Luminosity scan - 20 uA
88493 09/18/04 18:37 cdaq Run 50139: Optics run
88492 09/18/04 18:17 Bosted First look at 3He target with beam
88491 09/18/04 17:58 gaskell q2 recovered
88490 09/18/04 17:42 johna Engine tweaks
88489 09/18/04 17:11 gaskell Q2 crash
88488 09/18/04 16:55 cdaq Run 50138: Optics run
88487 09/18/04 16:37 johna Updated threshold files
88486 09/18/04 16:23 cdaq Run 50137: Optics run
88485 09/18/04 15:56 gaskell Summary of SOS sive slit runs at P=1.2 Gev
88484 09/18/04 15:51 johna Removed root trees from online engine.
88483 09/18/04 15:49 gaskell Q2 ramp rate lowered to 0.5 amp/s
88482 09/18/04 15:46 gaskell put nominal beam positions in error checking code
88481 09/18/04 15:45 cdaq Run 50136: Optics run
88480 09/18/04 15:33 fomin repeated ESR alarms
88479 09/18/04 15:30 ioana shift summary
88478 09/18/04 15:26 gaskell Nominal Beam Position
88477 09/18/04 15:25 cdaq Run 50135: Dummy, Beam position test, sieve slit in
88476 09/18/04 15:18 fomin sos angle camera grab
88475 09/18/04 15:08 cdaq Run 50134: Dummy, Beam position test, sieve slit in
88474 09/18/04 15:03 cdaq Run 50133: Dummy, Beam position test, sieve slit in
88473 09/18/04 14:56 cdaq Run 50132: Dummy, Beam position test, sieve slit in
88472 09/18/04 14:53 cdaq Run 50131: Dummy, Beam position test, sieve slit in
88471 09/18/04 14:43 cdaq Run 50130: 3% Carbon, Beam position test, sieve slit in
88470 09/18/04 14:22 cdaq Run 50129: 3% Carbon, Beam position test, sieve slit in
88469 09/18/04 13:40 cdaq Run 50128: 3% Carbon, Beam position test, sieve slit in
88468 09/18/04 13:26 gabriel Q2 finally up
88467 09/18/04 13:07 cdaq Run 50127: 3% Carbon, Beam position test, sieve slit in
88466 09/18/04 13:05 fomin target moved from C3 to carbon optics
88465 09/18/04 12:55 gabriel
88464 09/18/04 12:31 cdaq Run 50126: 3% Carbon, Beam position test, sieve slit in
88463 09/18/04 12:28 gabriel
88462 09/18/04 12:18 gabriel
88461 09/18/04 12:09 gabriel Q2 crash
88460 09/18/04 12:08
88459 09/18/04 12:05 cdaq Run 50125: 3% Carbon, Beam position test, sieve slit in
88458 09/18/04 11:47 gabriel Results of test for Peter
88457 09/18/04 11:44 cdaq Run 50124: 3% Carbon, Beam position test, sieve slit in
88456 09/18/04 11:29 cdaq Run 50123: 3% Carbon, Beam position test, sieve slit in
88455 09/18/04 11:28 cdaq Run 50122: 3% Carbon, Beam position test, sieve slit in
88454 09/18/04 10:47 gaskell Do not use 10% carbon target
88453 09/18/04 10:44 fomin Target moved to C3 from C10
88452 09/18/04 10:39 fomin Cryo target Lifter
88451 09/18/04 10:32 fomin IOC reboot, loop2 problem
88450 09/18/04 10:22 cdaq Run 50121: J/PSI run, 10% carbon target, Psos=+1.69
88449 09/18/04 09:43 cdaq Run 50120: J/PSI run, 10% carbon target, Psos=+1.69
88448 09/18/04 08:20 fomin target ESR alarm
88447 09/18/04 08:18 cdaq Run 50119: J/PSI run, 10% carbon target, Psos=+1.69
88446 09/18/04 08:09 cdaq Run 50118: J/PSI run, 10% carbon target, Psos=+1.69
88445 09/18/04 08:09 fomin target checklist
88444 09/18/04 07:50 slifer target: screen capture
88443 09/18/04 07:47 bradf setting up for J/psi test
88442 09/18/04 07:42 cdaq Run 50117: J/PSI run, 10% carbon target, Psos=+1.69
88441 09/18/04 07:39 b filippone HMS problems
88440 09/18/04 07:32 b filippone
88439 09/18/04 07:31 b
88438 09/18/04 07:17 cdaq Run 50116: testrun, 10% carbon target, Psos=+1.69
88437 09/18/04 07:16 cdaq Run 50115: testrun, 10% carbon target, Psos=+1.69
88436 09/18/04 05:28 cdaq Run 50114: harpscan
88435 09/18/04 04:53 cdaq Run 50113: harpscan
88434 09/18/04 03:59 cdaq Run 50112: sieve in hms and sos
88433 09/18/04 03:49 cdaq Run 50111: sieve in hms and sos
88432 09/18/04 03:40 johna Electronics checkout, PID thresholds, Cerenkov ADC gates
88431 09/18/04 03:34 cdaq Run 50110: junk
88430 09/18/04 03:24 cdaq Run 50109: junk
88429 09/18/04 03:16 cdaq Run 50108: junk
88428 09/18/04 03:10 cdaq Run 50107: junk
88427 09/18/04 03:03 cdaq Run 50106: junk
88426 09/18/04 02:48 cdaq Run 50105: junk
88425 09/18/04 02:45 gaskell new sos angle vernier crooked
88424 09/18/04 02:43 cdaq Run 50104: junk
88423 09/18/04 01:52 cdaq Run 50103: junk
88422 09/18/04 01:32 cdaq Run 50102: 10 muA 3%C
88421 09/18/04 01:28 cdaq Run 50101: 10 muA 3%C
88420 09/18/04 01:22 slifer target motion
88419 09/18/04 01:04 B filippone ethane alarm
Friday
88418 09/17/04 21:17 johna Pion prescaling circut setup for HMS and SOS
88417 09/17/04 19:10 horn HMS Door problem
88416 09/17/04 18:52 horn Target Alarm Handler GUI
88415 09/17/04 18:41 horn HMS Q2 Dump switch
88414 09/17/04 18:13 horn Target: GUI Screenshot
88413 09/17/04 17:42 smithg target situation and repair plan
88412 09/17/04 14:56 smithg target cooldown finished- but there is a leak
88411 09/17/04 11:32 gaskell He3 and He4 Density Plots
88410 09/17/04 09:52 smithg target cooldown started
88409 09/17/04 08:52 cdaq Run 50100: more cosmics
Thursday
88408 09/16/04 20:24 gaskell Hall status
88407 09/16/04 17:40 smithg target cooldown status
88406 09/16/04 16:41 nakahara TLD readings
88403 09/16/04 11:33 gaskell HMS calorimeter
88402 09/16/04 10:42 fomin Cherenkov calibration
88401 09/16/04 07:44 gaskell Can'r ramp HMS dipole to 5.25 GeV
88400 09/16/04 07:18 gaskell HMS dipole trip and polarity switch
88399 09/16/04 07:13 gaskell SOS BM02
88398 09/16/04 07:05 gaskell Magnet status
Wednesday
88397 09/15/04 15:20 gaskell updated BCM calibrations in epics
88396 09/15/04 15:05 cdaq Run 50099: ts test
88395 09/15/04 14:49 fomin Q3 max current
88394 09/15/04 14:44 cdaq Run 50098: ts test
88393 09/15/04 14:38 beaufait trigger supervisor repair
88392 09/15/04 07:55 gaskell sos magnets on
88391 09/15/04 07:52 gaskell trigger supervisor dead again
Tuesday
88390 09/14/04 18:37 cdaq Run 50097: overnight cosmic run (really)
88389 09/14/04 18:31 cdaq Run 50096: overnight cosmic run
88388 09/14/04 13:25 cdaq Run 50095: test
88387 09/14/04 11:16 cdaq Run 50094: test
88386 09/14/04 11:04 cdaq Run 50093: test
88385 09/14/04 11:01 cdaq Run 50092: test
88384 09/14/04 10:55 cdaq Run 50091: test
88383 09/14/04 10:19 cdaq Run 50090: test
88382 09/14/04 10:01 cdaq Run 50089: test
88381 09/14/04 09:56 cdaq Run 50088: test
88380 09/14/04 09:52 cdaq Run 50087: test
88379 09/14/04 09:44 cdaq Run 50086: test
88378 09/14/04 09:21 gaskell trigger supervisor - dead again
Monday
88376 09/13/04 18:16 cdaq Run 50085: long cosmic test
88375 09/13/04 18:13 cdaq Run 50084: cosmic test
88374 09/13/04 18:09 cdaq Run 50083: cosmic test
88373 09/13/04 18:04 cdaq Run 50082: cosmic test
88372 09/13/04 17:57 cdaq Run 50081: cosmic test
88371 09/13/04 17:31 cdaq Run 50080: cosmic test
88370 09/13/04 17:25 cdaq Run 50079: cosmic test
88369 09/13/04 17:23 cdaq Run 50078: cosmic test
88368 09/13/04 17:18 cdaq Run 50077: cosmic test
88367 09/13/04 17:15 cdaq Run 50076: cosmic test
88366 09/13/04 17:08 cdaq Run 50075: cosmic test
88365 09/13/04 17:02 cdaq Run 50074: cosmic test
88364 09/13/04 16:56 cdaq Run 50073: cosmic test
88363 09/13/04 16:50 cdaq Run 50072: cosmic test
88362 09/13/04 16:38 cdaq Run 50071: cosmic test
88361 09/13/04 14:51 cdaq Run 50070: cosmic test
88360 09/13/04 14:45 cdaq Run 50069: cosmic test
88359 09/13/04 14:38 cdaq Run 50068: cosmic test
88358 09/13/04 14:31 cdaq Run 50067: cosmic test
88357 09/13/04 14:25 cdaq Run 50066: cosmic test
88356 09/13/04 14:04 cdaq Run 50065: cosmic test
88355 09/13/04 13:22 cdaq Run 50064: cosmic test
88354 09/13/04 12:08 fomin hms sos angle marks
88353 09/13/04 11:11 HMS aerogel removed
Saturday
88352 09/11/04 18:36 cdaq Run 50063: cosmic test
88351 09/11/04 18:33 gaskell HMS scintillator ADC ribbon cables
88350 09/11/04 18:28 cdaq Run 50062: junk
88349 09/11/04 18:22 cdaq Run 50061: junk
88348 09/11/04 18:16 gaskell strange replay error
88347 09/11/04 18:13 cdaq Run 50060: junk
88346 09/11/04 18:11 cdaq Run 50059: junk
88345 09/11/04 18:09 cdaq Run 50058: junk
88344 09/11/04 18:05 cdaq Run 50057: junk
88343 09/11/04 18:04 cdaq Run 50056: junk
88342 09/11/04 17:57 gaskell trigger supervisor crate dies again
Friday
88341 09/10/04 18:04 cdaq Run 50055: cosmic test
88340 09/10/04 18:02 cdaq Run 50054: junk
88339 09/10/04 18:00 cdaq Run 50053: junk
88338 09/10/04 17:52 cdaq Run 50052: junk
88337 09/10/04 17:51 cdaq Run 50051: junk
88336 09/10/04 17:43 cdaq Run 50050: junk
88335 09/10/04 17:42 cdaq Run 50049: junk
88334 09/10/04 17:36 cdaq Run 50048: junk
88333 09/10/04 17:31 cdaq Run 50047: junk
88332 09/10/04 17:28 cdaq Run 50046: junk
88331 09/10/04 17:24 gaskell HMS cer correction
88330 09/10/04 17:19 cdaq Run 50045: junk
88329 09/10/04 17:16 cdaq Run 50044: junk
88328 09/10/04 17:08 cdaq Run 50043: junk
88327 09/10/04 13:51 cdaq Run 50042: cosmic test
88326 09/10/04 13:44 gaskell HMS cer HV
88325 09/10/04 13:40 gaskell scer hv
Thursday
88323 09/09/04 17:40 cdaq Run 50041: cosmic test -with drift chambers
88322 09/09/04 17:37 gaskell changed scer1 hv
88320 09/09/04 15:16 cdaq Run 50040: cosmic test -with drift chambers
88319 09/09/04 14:56 cdaq Run 50039: cosmic test -with drift chambers
88318 09/09/04 14:47 cdaq Run 50038: cosmic test -with drift chambers
88317 09/09/04 14:35 cdaq Run 50037: cosmic test -with drift chambers
88316 09/09/04 14:27 cdaq Run 50036: cosmic test -with drift chambers
Wednesday
88314 09/08/04 18:24 cdaq Run 50035: cosmic test -with drift chambers
88307 09/08/04 14:44 cdaq Run 50034: cosmic test -with drift chambers
Tuesday
88289 09/07/04 17:00 cdaq Run 50033: cosmic test - no drift chambers
88288 09/07/04 16:27 gaskell Moved HV channel
88287 09/07/04 16:08 gaskell BCM1 and BCM2 gain to setting 2
88285 09/07/04 09:20 gaskell do not turn on drift chamber HV
Friday
88280 09/03/04 18:12 gaskell All HV off
88279 09/03/04 18:09 gaskell trigger supervisor crate croaked again
88278 09/03/04 15:47 cdaq Run 50031: cosmic test - Calorimeter and aerogel check.
88277 09/03/04 15:04 cdaq Run 50030: cosmic test - Calorimeter and aerogel check.
88276 09/03/04 14:52 saw Trigger fixed
88275 09/03/04 14:43 cdaq Run 50029: cosmic test - Calorimeter and aerogel check.
88274 09/03/04 14:25 cdaq Run 50028: cosmic test - Calorimeter and aerogel check.
88273 09/03/04 14:08 cdaq Run 50027: cosmic test - Calorimeter and aerogel check.
Thursday
88272 09/02/04 16:01 gaskell no trigger
88271 09/02/04 15:52 cdaq Run 50025: cosmic test - Calorimeter and aerogel check.
88270 09/02/04 15:45 cdaq Run 50024: cosmic test - Calorimeter and aerogel check.
88269 09/02/04 15:30 cdaq Run 50023: cosmic test - Calorimeter and aerogel check.
88268 09/02/04 12:25 cdaq Run 50022: cosmic test - Calorimeter and aerogel check.
88267 09/02/04 12:23 razmilk hms cosmic test
88266 09/02/04 12:16 cdaq Run 50021: cosmic test - looking for triggers!
88265 09/02/04 11:35 cdaq Run 50020: cosmic test - looking for triggers!
88264 09/02/04 11:31 gaskell HMS and SOS HV on
88263 09/02/04 11:22 cdaq Run 50019: cosmic
88262 09/02/04 11:09 cdaq Run 50018: cosmic
88261 09/02/04 11:05 cdaq Run 50017: Cosmics
88260 09/02/04 10:59 cdaq Run 50016: LH2,SOS P=1.73 th= 32.32, HMS P=2.074, th=16.99
88259 09/02/04 10:58 cdaq Run 50015: cosmic run
88258 09/02/04 10:55 cdaq Run 50014: Cosmic run - HMS and SOS
Wednesday
88257 09/01/04 11:11 gaskell Drift chamber gas flows