Entry number 102205
keyword=ROC 12, slot 10 F1 Failed to Initialize
ROC 12, slot 10 F1 Failed to Initialize at prestart.
Soft reboot did not help.So, power cycled.
=========================================================================
interrupt: ERROR: Not all modules converted! Datascan: 0x55000, Event
type: 4,
Event=888
interrupt: ERROR: Not all modules converted! Datascan: 0x55000, Event
type: 4,
Event=900
interrupt: ERROR: Not all modules converted! Datascan: 0x55000, Event
type: 4,
Event=912
interrupt: ERROR: Not all modules converted! Datascan: 0x55000, Event
type: 4,
Event=924
interrupt: ERROR: Not all modules converted! Datascan: 0x55000, Event
type: 4,
Event=936
-> f1GClear
value = 0 = 0x0
-> f1GStatus
STATUS for TDC in slot 10 at base address 0xfaef0000
--------------------------------------------------
Firmware Revsion/ID = 0xf1da
Alternate VME Addressing: Multiblock Enabled
A32 Enabled at VME base 0x08000000 or CPU addr 0x10000000
Muliblock VME Address Range 0x09800000 - 0x0a800000
Configuration:
USING Signal Distribution card at 0xfbff0ee0
Control Inputs from Front Panel
Internal Clock OFF
Use EXTERNAL Clock
Bus Error DISABLED
MultiBlock transfer ENABLED (First Board)
CSR Register = 0xf026ffd0 - Error Condition
Control Register = 0x00ff0184
Events in FIFO = 0 (Block level = 1)
CHIP Status: (slot 10)
CHIP 0 Reg = 0x0140 - NOT Initialized
CHIP 1 Reg = 0x0140 - NOT Initialized
CHIP 2 Reg = 0x0140 - NOT Initialized
CHIP 3 Reg = 0x0140 - NOT Initialized
CHIP 4 Reg = 0x0140 - NOT Initialized
CHIP 5 Reg = 0x0140 - NOT Initialized
CHIP 6 Reg = 0x0140 - NOT Initialized
CHIP 7 Reg = 0x0140 - NOT Initialized
-> m 0xfbff0ed0,2
fbff0ed0: 0580-
fbff0ed2: ff00-
fbff0ed4: ef10-
fbff0ed6: ff00-
fbff0ed8: f000-
fbff0eda: ffff-
fbff0edc: ffff-
fbff0ede: ffff-
fbff0ee0: ff03-
fbff0ee2: ffff-
=========================================================================
A copy of this log entry has been emailed to: saw@jlab.org,abbottd@jlab.org,jastrzem@jlab.org