Main INDEX,
Monthly INDEX,
PREV,
NEXT
Make New Entry,
Make Followup Entry
User name Solvignon
Log entry time 16:02:11 on July 1,2007
Entry number 141297
keyword=Shift Summary
Day Shift Summary
SL: Patricia Solvignon
Target: Peter Bosted
Third : Wei Luo
Time-line
- 08:00-09:35 Finishing Q2=0.983 while waiting for pass change.
- 09:35-11:00 Pass change. Energy is now 2.851GeV
- 11:00-12:05 MCC working on beam spot size. Best they can get is 75umx71um.
- 12:06-13:42 Start production data at Q2=4.25
- 13:42-????? Dipole NMR communication error
-
-
List of Runs
- 64877: Production, Dummy, P=+1.121 GeV and Theta=54.34 deg. ps1=2; ps2=36; ps3=99999 --> Junk (high DT)
- 64878: Production, Dummy, P=+1.121 GeV and Theta=54.34 deg. ps1=4; ps2=36; ps3=99999 --> Good run
- 64879: Production, Dummy, P=+1.121 GeV and Theta=54.34 deg. ps1=4; ps2=36; ps3=99999 --> Junk (very short)
- 64880: Production, Carbon, P=+1.121 GeV and Theta=54.34 deg. ps1=4; ps2=2; ps3=99999 --> Good run
- 64881: Production, Dummy, P=+1.121 GeV and Theta=54.34 deg. ps1=4; ps2=36; ps3=99999 --> Good run
- 64882: Production, LH2, P=+1.121 GeV and Theta=54.34 deg. ps1=4; ps2=36; ps3=99999 --> 0.3M
- 64883: Production, LH2, P=+1.121 GeV and Theta=54.34 deg. ps1=1; ps2=36; ps3=99999 --> 2M
- 64884: Production, LH2, P=+1.121 GeV and Theta=54.34 deg. ps1=1; ps2=36; ps3=99999 --> 2M
- 64885: Production, LH2, P=+1.121 GeV and Theta=54.34 deg. ps1=1; ps2=36; ps3=99999 --> 2M
- 64886: Production, LH2, P=+1.121 GeV and Theta=54.34 deg. ps1=1; ps2=36; ps3=99999 --> 2M
- 64887: Production, LH2, P=+1.121 GeV and Theta=54.34 deg. ps1=1; ps2=36; ps3=99999 --> 2M
- 64888: Cosmics
- 64892: Production, Carbon, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> Good run
- 64893: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> 2M HMS triggers = 14k elastics
- 64894: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> 2M HMS triggers = 14k elastics
- 64895: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> 2M HMS triggers = 14k elastics
- 64896: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> 2M HMS triggers = 14k elastics
- 64897: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> 2M HMS triggers = 14k elastics
- 64898: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> 2M HMS triggers = 14k elastics
- 64899: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> 1.4M HMS triggers = 9.8k elastics (Stopped because of NMR communication problem
- 64900: Production, LH2, P=+3.063 GeV and Theta=10.635 deg. ps1=1; ps2=36; ps3=99999 --> might be junk