Beam Energy (MeV) | 4197.28 | 1.443 |
HMS Momentum (GeV/c) | 1.30800 | 1.30800 |
Q1 Set Current | 170.32 | 170.32 |
Q2 Set Current | 135.32 | 135.32 |
Q3 Set Current | 66.17 | 66.17 |
Q1 B Field (G) | 2254.0000 | 2254.0000 |
Q2 B Field (G) | -2745.3000 | -2745.3000 |
Q3 B Field (G) | 1332.4000 | 1332.4000 |
D Current Readback | 13295.0 | 13295.0 |
B_true | 0.35947 | 0.35947 |
Q1 Polarity | 1.0 | 1.0 |
Q2 Polarity | 0.0 | 0.0 |
Q3 Polarity | 1.0 | 1.0 |
Dipole Polarity | 0.0 | 0.0 |
HMS Angle | 33.70 | 21.07 |
SOS Angle | 147.00 | 147 |
Beam Current (uA) | 80.02 | 80.02 |
Target Encoder | 12457104 | 12457104 |
Target Encoder | 12457104 | 12457104 |
Fast Raster size (mmxmm) | 2x2 | 2x2 |
Target - carbon
HMSmom= 1.308
I=80uA
thHMS=33.695
Pion collimator,
ps1=1, ps2=2, ps3=99999
DAQ in coin mode
seive in