**************************** Run Number: 7447 End of Run Comment: Took 4M events without problems from ROC9 *** EPICS values at end of run *** Beam current BCM1 = 0.05 uA Beam current BCM2 = 0.09 uA Beam current BCM17 = -71.89 uA Beam Energy = 1162.06 MeV Qweak magnet current = 0.30 A Qweak magnetic field = 0.15 G HalfWave Plate state = OUT Qweak Target : HYDROGEN-CELL (QWtgt_name) Hall C fasst feedback : On (FB_C:FB_On) Hall C energy lock : RF On (FB_C:use_RF) Hall A energy lock : RF Off (FB_A:use_RF) Raster (width) X mm : 3 (EHCFR_LIXWidth) Raster (height) Y mm : 3 (EHCFR_LIYWidth) Wien angle (Vertical) : 90.0005 (VWienAngle) Wien Vertical BDL (Gcm) : 2632.9 (MWF1I04.BDL) Wien HV Polarity : POSITIVE (IGL1I00OD16_4) Wien electrode Voltage : 0 (IGL1I00DAC6) Wien angle (Solenoids) : 90 (Phi_FG) Wien BDL (First Solenoid) (Gcm) : 998.89 (MFG1I04A.BDL) Wien BDL (Second Solenoid) (Gcm) : 998.89 (MFG1I04B.BDL) Wien angle (Horizontal) : -61.0017 (HWienAngle) Wien BDL (Gcm) : -1754.8 (MWF0I02.BDL) Wien HV Polarity (Horizontal) : NEGATIVE (IGL1I00OD16_9) Wien electrode Voltage (Horizontal) : 0 (IGL1I00DAC5) Beam Half-wave plate Set(off=out) : OUT (IGL1I00OD16_16) Beam Half-wave plate Read(off=out) : OUT (IGL1I00DI24_24M) Rotating waveplate : 233 (psub_pl_pos) IA Cell Setpoint Hall A : 4.96 (IGLdac3:ao_7) IA Cell Setpoint Hall B : 0.46398 (IGL1I00AI20) IA Cell Setpoint Hall C : 3 (IGLdac3:ao_4) Gun2: PC (PITA) POS : 7.5 (IGLdac2:G2Ch3Pos) Gun2: PC (PITA) NEG : 5 (IGLdac2:G2Ch4Neg) Pockels Cell ON/OFF : ON (IGL1I00OD16_8) Pockels Cell X Stage : -0.0031 (cdipc_xpos) Pockels Cell Y Stage : 0.00465 (cdipc_ypos) Wager X Stage : 650 (psub_cx_pos) Wager Y Stage : 675 (psub_cy_pos) Helicity Clock Set : Free Clock (HELCLOCKs) Helicity Delay Set : 8 windows (HELDELAYs) Helicity Pattern Set : Quartet (HELPATTERNs) Helicity Clock Read : Free Clock (HELCLOCKd) Helicity Settle Read : 70 (HELTSETTLEd) Helicity Stable Read : 971.65 (HELTSTABLEd) Helicity Delay Read : 8 windows (HELDELAYd) Helicity Pattern Read : Quartet (HELPATTERNd) Helicity Frequency : 960.015 (HELFREQ) ******************************************* *** PRESCALE FACTORS *** PS1 = -1 PS2 = -1 PS3 = 16777215 PS4 = 5 PS5 = 65535 PS6 = 65535 PS7 = 1 PS8 = 65535 TS0 keywords: no_tsprogram1 ******************************************* *** VQWK SETTINGS *** ROC1 vqwkperiod = 0 ROC1 vqwkblocks = 4 ROC1 vqwksamples = 116 ROC1 vqwkdelay = 20 ROC1 vqwkinternal = 2 ROC2 vqwkperiod = 0 ROC2 vqwkblocks = 4 ROC2 vqwksamples = 116 ROC2 vqwkdelay = 20 ROC2 vqwkinternal = 2 ****************************