Jefferson Lab Hall C Logbook for November 10 - Compton
Main INDEX
Tuesday
209255 11/30/10 21:21 dalton Compton: Chicane threading
209183 11/30/10 14:50 narayan Compton: work in Hall: calibration input, motion controller, re-installation of beam right QWADs
209130 11/30/10 03:02 narayan Compton: e-detector view port image
Monday
209078 11/29/10 19:28 dalton Compton: Laser off for tonight
Sunday
208951 11/28/10 18:20 narayan Compton: beam reduced , extremely high halo
208916 11/28/10 14:41 dalton Compton: photon detector off
208912 11/28/10 14:31 dalton Compton: epic halo rates
208880 11/28/10 11:33 dalton Compton: photon detector trip
Saturday
208823 11/27/10 23:57 dzou Compton: Accumulator asymmetry and yield plots
Friday
208589 11/26/10 15:09 paschke gask Compton: mini vertical scan, signal/bkg ~ 1.5
208583 11/26/10 14:53 paschke gask Compton: starting y-scan in compton chicane
208514 11/26/10 09:55 gaskell Compton: table scintillator rates look ok
Thursday
Wednesday
Tuesday
208203 11/23/10 15:16 donjones Compton: EPICS updating again on ccompt
Monday
208005 11/22/10 09:10 narayan Compton: e-detector studies
Sunday
207960 11/21/10 23:22 W. Deconinck Compton: Updated analyzer to revision 2235
207910 11/21/10 20:39 narayan Compton: enabled 0.2 mm move of e-detector
207909 11/21/10 20:26 W. Deconinck Compton: Photon detector HV off again
207865 11/21/10 13:05 dalton Compton: Photon detector backgrounds, time for a task team?
207850 11/21/10 08:59 gaskell Compton: leave photon detector off if it trips
207836 11/21/10 06:29 narayan Compton: Photon detector HV-6 keeps tripping
207825 11/21/10 03:15 donjones Compton: rates in Compton all over the place--tripping HV
Saturday
207785 11/20/10 20:15 dalton Compton: caput.exe error with a twist
207781 11/20/10 20:09 dalton Compton: Changes to DAQ
207748 11/20/10 15:13 dalton Compton: Amplifying transmitted photodiode signal
207742 11/20/10 14:55 W. Deconinck Compton: Disabled Windows XP error reporting for caput.exe
207731 11/20/10 13:57 dalton Compton: caput.exe error at 13:55
207722 11/20/10 12:43 dalton Compton: caput.exe error at 19:30 Friday
Friday
207563 11/19/10 17:13 dalton Compton: caput.exe error at 15:28
207559 11/19/10 16:58 dalton Compton: Lead in front of photon detector
207498 11/19/10 13:36 gaskell Compton: Crude BCM17 calibration
207473 11/19/10 11:26 dalton Compton: caput.exe error at 11:16
207462 11/19/10 10:15 dalton Compton: background rates correlated to vacuum in arc?
207441 11/19/10 09:22 dalton Compton: caput.exe error at 10:59 Thursday
Thursday
207278 11/18/10 16:17 narayan Compton: electron detector HV
Wednesday
207183 11/17/10 22:52 W. Deconinck Compton: Asymmetries in FADC accumulators
207015 11/17/10 07:46 narayan Compton: e-detector studies
206946 11/17/10 01:02 narayan Compton: after controlled access today, beam was intially sent straight through
Tuesday
206909 11/16/10 18:46 dalton Compton: caput.exe error at 18:39
206900 11/16/10 17:09 narayan Compton: BLM trip at 1 uA, cw, with detector 2 cm away from beam
206861 11/16/10 13:22 dalton Compton: HV 'DEAD' alarm
206838 11/16/10 10:20 dalton Compton: caput.exe error at 22.53
Monday
206749 11/15/10 20:51 dalton Compton: FADC spectra at 1600 V
206748 11/15/10 20:44 dalton Compton: FADC spectra at 1650 V
206746 11/15/10 20:15 dalton Compton: caput.exe error at 17:50
206713 11/15/10 16:29 dalton Compton: BCM17 offset added
206708 11/15/10 15:58 dalton Compton: BCM17 attenuation added
206657 11/15/10 10:51 dalton Compton: Further changes to HV
206654 11/15/10 10:41 dalton Compton: HV communication restored
206555 11/15/10 00:35 W. Deconinck Compton: HV Moller and Compton split up (but both not working)
206550 11/15/10 00:23 W. Deconinck Compton: first100k and Pass1 autoanalyzers running on ccomptl1
Sunday
206394 11/14/10 08:50 gaskell Compton: Found HV off - ended run
206393 11/14/10 08:36 gaskell Compton: Rebooted iochc10
206390 11/14/10 08:32 gaskell Compton: disconnected BCM17 from Compton ADC
206299 11/14/10 05:23 narayan Compton: e-detector motion controller not responding
Saturday
206207 11/13/10 23:33 narayan Compton: HV had tripped was turned ON again
206125 11/13/10 16:40 W. Deconinck Compton: Set FADC thresholds to values suggested by Mark
206103 11/13/10 15:08 dalton Compton: Spectra from the flash ADC
205909 11/13/10 04:34 W. Deconinck Compton: DAQ & analyzer status
Friday
Thursday
205424 11/11/10 17:40 dalton Compton: Overnight spectrum
205423 11/11/10 17:28 narayan Compton: Compton electron detector studies
205389 11/11/10 09:18 donjones Compton: Graph of Compton lock
Wednesday
Tuesday
205121 11/09/10 23:39 michaelm Compton: Scan for compton interaction region
Monday
Sunday
Saturday
204284 11/06/10 21:23 dalton Compton: Laser mirrors homed with laser on
204199 11/06/10 16:20 dalton Compton: Compton spectrum with new detector and new DAQ
Friday
203885 11/05/10 15:49 gaskell Compton: photon detector moved to EEL 126
Thursday
203748 11/04/10 00:16 W. Deconinck Compton: Enabled split CODA files (at 1.9 GB)
Wednesday
Tuesday
Monday
203522 11/01/10 20:08 dalton Compton: Background spectrum depends on beam current
203511 11/01/10 17:54 dalton Compton: Energy dependent asymmetry