**************************** Run Number: 9317 End of Run Comment: Found a problem: the ROC1 acknowledge signal sometimes does not get sent for several events, even though the CRL trigger service routine has exited. This is the cause of the triger supervisor busy and the missed helicity gates. *** EPICS values at end of run *** Beam current BCM1 = -0.00 uA Beam current BCM2 = 0.08 uA Beam current BCM17 = -56.46 uA Beam Energy = 1162.06 MeV Qweak magnet current = 0.40 A Qweak magnetic field = 0.14 G HalfWave Plate state = OUT Qweak Target : HYDROGEN-CELL (QWtgt_name) Hall C fast feedback : On (FB_C:FB_On) Hall C fast feedback : 0 (FB_C:status:ON) Hall C energy lock : RF On (FB_C:use_RF) Hall A energy lock : RF Off (FB_A:use_RF) Raster (width) X mm : 3.5 (EHCFR_LIXWidth) Raster (height) Y mm : 3.5 (EHCFR_LIYWidth) Wien angle (Vertical) : 88.825 (VWienAngle) Wien Vertical BDL (Gcm) : 2143.9 (MWF1I04.BDL) Wien HV Polarity : POSITIVE (IGL1I00OD16_4) Wien electrode Voltage : 0 (IGL1I00DAC6) Wien angle (Solenoids) : 89.7547 (Phi_FG) Wien BDL (First Solenoid) (Gcm) : 876 (MFG1I04A.BDL) Wien BDL (Second Solenoid) (Gcm) : 857 (MFG1I04B.BDL) Wien angle (Horizontal) : -63.1997 (HWienAngle) Wien BDL (Gcm) : -1422.6 (MWF0I02.BDL) Wien HV Polarity (Horizontal) : NEGATIVE (IGL1I00OD16_9) Wien electrode Voltage (Horizontal) : 0 (IGL1I00DAC5) Beam Half-wave plate Set(off=out) : OUT (IGL1I00OD16_16) Beam Half-wave plate Read(off=out) : OUT (IGL1I00DI24_24M) Rotating waveplate : 3950 (psub_pl_pos) IA Cell Setpoint Hall A : 4.96 (IGLdac3:ao_7) IA Cell Setpoint Hall B : 0.481074 (IGL1I00AI20) IA Cell Setpoint Hall C : 3 (IGLdac3:ao_4) Gun2: PC (PITA) POS : 7.5 (IGLdac2:G2Ch3Pos) Gun2: PC (PITA) NEG : 5 (IGLdac2:G2Ch4Neg) Pockels Cell ON/OFF : ON (IGL1I00OD16_8) Pockels Cell X Stage : 0.0055 (cdipc_xpos) Pockels Cell Y Stage : -0.04745 (cdipc_ypos) Wager X Stage : 750 (psub_cx_pos) Wager Y Stage : 700 (psub_cy_pos) Helicity Clock Set : Free Clock (HELCLOCKs) Helicity Delay Set : 8 windows (HELDELAYs) Helicity Pattern Set : Quartet (HELPATTERNs) Helicity Clock Read : Free Clock (HELCLOCKd) Helicity Settle Read : 70 (HELTSETTLEd) Helicity Stable Read : 971.65 (HELTSTABLEd) Helicity Delay Read : 8 windows (HELDELAYd) Helicity Pattern Read : Quartet (HELPATTERNd) Helicity Frequency : 960.015 (HELFREQ) ******************************************* *** PRESCALE FACTORS *** PS1 = 0 PS2 = 16777215 PS3 = 16777215 PS4 = 16777215 PS5 = 65535 PS6 = 65535 PS7 = 65535 PS8 = 65535 TS0 keywords: no_tsprogram1 ******************************************* *** VQWK SETTINGS *** TS0 vqwksamples = 116 TS0 vqwkdelay = 20 TS0 vqwkblocks = 4 TS0 vqwkperiod = 0 ROC1 vqwksamples = 116 ROC1 vqwkdelay = 20 ROC1 vqwkblocks = 4 ROC1 vqwkperiod = 0 ROC1 vqwkinternal = 2 ROC2 vqwksamples = 116 ROC2 vqwkdelay = 20 ROC2 vqwkblocks = 4 ROC2 vqwkperiod = 0 ROC2 vqwkinternal = 2 ****************************