**************************** Run Number: 10661 End of Run Comment: junk. RII Hokies' tripped. *** EPICS values at end of run *** Beam current BCM1 = -0.02 uA Beam current BCM2 = -0.03 uA Beam current BCM17 = -58.15 uA Beam Energy = 1162.06 MeV Qweak magnet current = 8919.70 A Qweak magnetic field = -710.54 G HalfWave Plate state = IN Qweak Target : DS-4%-Aluminum (QWtgt_name) Hall C fast feedback : Off (FB_C:FB_On) Hall C fast feedback : 0 (FB_C:status:ON) Hall C energy lock : RF Off (FB_C:use_RF) Hall A energy lock : RF On (FB_A:use_RF) Raster (width) X mm : 3.5 (EHCFR_LIXWidth) Raster (height) Y mm : 3.5 (EHCFR_LIYWidth) Wien angle (Vertical) : 87.104 (VWienAngle) Wien Vertical BDL (Gcm) : 2548.2 (MWF1I04.BDL) Wien HV Polarity : POSITIVE (IGL1I00OD16_4) Wien electrode Voltage : 0 (IGL1I00DAC6) Wien angle (Solenoids) : 89.9198 (Phi_FG) Wien BDL (First Solenoid) (Gcm) : 998 (MFG1I04A.BDL) Wien BDL (Second Solenoid) (Gcm) : 998 (MFG1I04B.BDL) Wien angle (Horizontal) : -62.3999 (HWienAngle) Wien BDL (Gcm) : -1794.6 (MWF0I02.BDL) Wien HV Polarity (Horizontal) : NEGATIVE (IGL1I00OD16_9) Wien electrode Voltage (Horizontal) : 0 (IGL1I00DAC5) Beam Half-wave plate Set(off=out) : IN (IGL1I00OD16_16) Beam Half-wave plate Read(off=out) : IN (IGL1I00DI24_24M) Rotating waveplate : 3950 (psub_pl_pos) IA Cell Setpoint Hall A : 4.96 (IGLdac3:ao_7) IA Cell Setpoint Hall B : 0 (IGL1I00AI20) IA Cell Setpoint Hall C : 3 (IGLdac3:ao_4) Gun2: PC (PITA) POS : 7.5 (IGLdac2:G2Ch3Pos) Gun2: PC (PITA) NEG : 5 (IGLdac2:G2Ch4Neg) Pockels Cell ON/OFF : ON (IGL1I00OD16_8) Pockels Cell X Stage : 0.0055 (cdipc_xpos) Pockels Cell Y Stage : -0.0475 (cdipc_ypos) Wager X Stage : 760 (psub_cx_pos) Wager Y Stage : 560 (psub_cy_pos) Helicity Clock Set : Free Clock (HELCLOCKs) Helicity Delay Set : 8 windows (HELDELAYs) Helicity Pattern Set : Quartet (HELPATTERNs) Helicity Clock Read : Free Clock (HELCLOCKd) Helicity Settle Read : 70 (HELTSETTLEd) Helicity Stable Read : 971.65 (HELTSTABLEd) Helicity Delay Read : 8 windows (HELDELAYd) Helicity Pattern Read : Quartet (HELPATTERNd) Helicity Frequency : 960.015 (HELFREQ) ******************************************* *** PRESCALE FACTORS *** PS1 = 0 PS2 = 30 PS3 = 16777215 PS4 = 16777215 PS5 = 65535 PS6 = 65535 PS7 = 65535 PS8 = 65535 TS0 keywords: no_tsprogram1 ******************************************* *** VQWK SETTINGS *** TS0 vqwksamples = 4170 TS0 vqwkdelay = 20 TS0 vqwkblocks = 4 TS0 vqwkperiod = 0 TS0 vqwkinternal = 3 ROC1 vqwksamples = 4170 ROC1 vqwkdelay = 20 ROC1 vqwkblocks = 4 ROC1 vqwkperiod = 0 ROC1 vqwkinternal = 3 ROC2 vqwksamples = 4170 ROC2 vqwkdelay = 20 ROC2 vqwkblocks = 4 ROC2 vqwkperiod = 0 ROC2 vqwkinternal = 3 ****************************