Jefferson Lab Hall C Logbook for May 11 - Full Listing
Main INDEX
Tuesday
233512 05/31/11 14:27 beaufait large moller quad
Monday
233511 05/30/11 14:11 leacock turned off target controls computer monitors
Friday
233510 05/27/11 13:39 brads VDC gas flow switchover defered to Friday, June 3
233509 05/27/11 13:27 brads VDC gas flow will be switched to Argon on Tuesday, May 31
Wednesday
233508 05/25/11 18:16 Pitt HDC Fast OR scaler rates compared to scope
233507 05/25/11 18:10 Pitt HDC "IN" leakage/FOR at 2300 V
233506 05/25/11 18:08 Pitt HDC "IN" leakage/FOR at 2250 V
233505 05/25/11 18:07 Pitt HDC "IN" Leakage/FOR for 2200 V
233504 05/25/11 18:06 Pitt HDC "IN" leakage/FOR at 2150 V
233503 05/25/11 18:04 Pitt HDC "IN" leakage/FOR at 2100 V
233502 05/25/11 18:03 Pitt HDC "IN" leakage/FOR at 2050 V
233501 05/25/11 18:02 Pitt HDC "IN" leakage/FOR at 2000 V
233500 05/25/11 18:00 Pitt HDC "IN" leakage/FOR at 1900 V
233499 05/25/11 17:59 Pitt HDC "IN" leakage/FOR at 1800 V
233498 05/25/11 17:58 Pitt HDC "IN" leakage/FOR at 1700 V
233497 05/25/11 17:56 Pitt HDC "IN" leakage/FOR at 1600 V
233496 05/25/11 17:54 Pitt HDC "IN" leakage/FOR at 1500 V
233495 05/25/11 17:49 Pitt Region 2 leakage/FOR rates for IN position
233494 05/25/11 16:16 saw ADC moved from vmec18 to vmec1
233493 05/25/11 14:53 Pitt HDC "OUT" leakage/FOR at 2300 V
233492 05/25/11 14:51 Pitt HDC 2250 V with pictures
233491 05/25/11 14:50 Pitt HDC "OUT" leakage/FOR at 2250 V
233490 05/25/11 14:49 Pitt HDC "OUT" leakage/FOR at 2200 V
233489 05/25/11 14:48 brads UPS in the gas shed needs a replacement battery
233488 05/25/11 14:47 Pitt HDC "OUT" leakage/FOR at 2150 V
233487 05/25/11 14:46 Pitt HDC "OUT" leakage/FOR at 2100 V
233486 05/25/11 14:44 Pitt HDC "OUT" leakage/FOR at 2050 V
233485 05/25/11 14:43 Pitt HDC "OUT" leakage/FOR rates at 2000 V
233484 05/25/11 14:41 Pitt HDC "OUT" leakage/FOR at 1900 V
233483 05/25/11 14:40 Pitt HDC "OUT" Leakage/FOR at 1800 V
233482 05/25/11 14:37 Pitt HDC Leakage/FOR at 1600 V
233481 05/25/11 14:36 Pitt HDC "OUT" Leakage/FOR at 1500 V
233480 05/25/11 14:32 Pitt Region 2 leakage current and Fast OR rates for OUT position
233479 05/25/11 14:30 Pitt Radiation levels at selected points in Region 2
233478 05/25/11 11:24 jhlee Re:Run 10647: LH2 HK2 10V threshold VDC 3500V HV octant 1+5 QTOR 8921A
Tuesday
233477 05/24/11 20:16 Pitt RADCON survey results from 5/20/2011
233476 05/24/11 18:34 armd vmec18 and VDC thresholds
233475 05/24/11 15:55 beaufait Target: target camera
233474 05/24/11 14:41 saw Qtor Hall Probe moved to vmec1
233472 05/24/11 11:49 brads re: UPS alarm in Hall C CH electronics room (powers IOCHLCBPM2) -- fixed
233471 05/24/11 11:47 brads gas flowing again
233470 05/24/11 10:42 covrig Target: recover from power outage
233469 05/24/11 09:21 brads gas flow tripped off sometime between noon yesterday and this morning
Monday
233468 05/23/11 16:44 brads ccompl2 is back down...
233467 05/23/11 16:33 brads ccomptl2 back up
233466 05/23/11 15:51 brads UPS alarm in Hall C CH electronics room (powers IOCHLCBPM2)
233465 05/23/11 11:30 Leckey R3 Covered and Parked for Summer
233464 05/23/11 10:05 brads cdaq computers back up, except for ccomptl2
233463 05/23/11 10:00 brads Gas flow back up as Ar:Ethane
Friday
233462 05/20/11 18:41 brads Gas flow to chambers will be interrupted over the weekend
233461 05/20/11 18:39 jhlee remove very old raw CODA files on cdaql6 local disk
233460 05/20/11 17:46 saw Hall C EPICS Archiver shutdown and restarted
233459 05/20/11 17:26 brads Hall C Computers will be shut down over the weekend
233458 05/20/11 16:24 mack Removed rad badges from MD focal plane
233457 05/20/11 16:16 pking Database server on cdaql6 is being worked on.
233456 05/20/11 15:52 Ramesh Analysis: result of the test run 12102 for bcm5,6 (with input signals from bcm1,2)
233455 05/20/11 15:47 jhlee several IOC crates are off
233454 05/20/11 14:34 gaskell Compton: turned off a lot of stuff
233453 05/20/11 14:18 jhlee updated JDK on cdaql4
233452 05/20/11 12:33 jhlee installation of afecs_v131b8 on cdaql4
233451 05/20/11 11:02 Pitt Region 2 RADCON survey information from May 18, 2011
233450 05/20/11 09:49 Pitt HDC leakage currents; 9:30 AM on 5/20/2011
Thursday
233449 05/19/11 21:55 brads cdaqlX machines will probably be shut off over the weekend
233448 05/19/11 18:09 jhlee a tweak for the injector DAQ
233447 05/19/11 18:00 leacock W plug test notes
Wednesday
233446 05/18/11 17:47 jhlee current working boot parameter on g0inj
233445 05/18/11 17:13 jhlee turn off the Parity ROCs and Tracking ROCs, and start to migrate the injector DAQ into cdaq cluster
233444 05/18/11 16:01 beaufait Large quad local controls are back up.
233443 05/18/11 15:36 beaufait g2p supplies disconnected and ready for removal.
233442 05/18/11 14:58 brads cdaql3 is back up
233441 05/18/11 13:39 leacock Region 2 HDC leakage currents at 13:35, 18 May 2011
233440 05/18/11 10:40 brads cdaql3 will be rebooted at 2pm, Wednesday (today)
Tuesday
233439 05/17/11 15:43 Pitt Region 2 RADCON survey information
233438 05/17/11 15:30 Pitt Region 2 HDC leakage currents at 15:20 on 5/17/2011
233437 05/17/11 10:47 beaufait power supply work
233436 05/17/11 10:47 Leckey VDC Mad Card Activated
Monday
233435 05/16/11 16:38 rob removed remaining six dosimeters from cable tray
233434 05/16/11 15:38 smithg,Silvi Target: Inerted loop with helium, moved to 4% US Al dummy
233433 05/16/11 13:03 Leckey VDC MAD Card Replaced
233432 05/16/11 11:01 saw Hall C Epics Archiver shutdown and restart on Wednesday
Sunday
233431 05/15/11 16:56 Pitt Region 2 HDC leakage currents - May 15, 16:30 - missing plot
233430 05/15/11 16:51 Pitt Region 2 HDC leakage currents - May 15, 16:30
233429 05/15/11 16:17 Pitt Region 2 HDC leakage currents - May 14, 15:00
Saturday
233428 05/14/11 19:04 dunne Final "as found" run plan calendar for last 10 days
Friday
233427 05/13/11 14:38 leacock HDC HV and current readouts at 1436 on 13 May 2011
233426 05/13/11 11:26 brads power-cycled hallc-cat2950 network switch in Hall
233425 05/13/11 11:00 saw Qtor trip data
233424 05/13/11 10:53 brads re: firefox is not working on cdaql3 -- fixed
233422 05/13/11 10:31 beaufait lcw shutdown
233421 05/13/11 10:11 smithg Target: checked tgt in hall
233420 05/13/11 10:06 covrig, smit Target: warming up
233419 05/13/11 09:52 gaskell Moller: warmup
233418 05/13/11 09:44 gaskell Compton: laser off, interlock disabled
233417 05/13/11 09:43 gaskell Compton: flippers removed from laser table
233416 05/13/11 08:08 narayan Compton: withdrawing for shutdown
233415 05/13/11 08:07 Armstrong Leave VDC and HDC gas flowing for now
233414 05/13/11 08:07 cdaq Beam Time Accounting
233413 05/13/11 08:05 cdaq End of Run 12163:
233412 05/13/11 08:02 rajotte Shift Summary: Owl shift summary
233411 05/13/11 08:00 gaskell Compton: Stuck flipper
233410 05/13/11 07:50 rajotte late entry: Qtor and HV are OFF
233409 05/13/11 07:42 narayan Compton: eDet HV turned off
233408 05/13/11 07:33 manos Target: Raster current alarm
233407 05/13/11 07:11 cdaq Run 12163 Pedestal Data
233406 05/13/11 07:08 cdaq Run 12163: pedestal
233405 05/13/11 07:04 cdaq End of Run 12162:
233404 05/13/11 07:03 cdaq Compton End of Run 22034 (standard):
233403 05/13/11 07:02 rajotte Beam OFF for six months
233402 05/13/11 06:59 manos Compton: No power in cavity
233401 05/13/11 06:52 cdaq Compton Run 22034 (standard): I=180uA, eDet beam on, laser off
233400 05/13/11 06:49 cdaq Compton End of Run 22033 (standard):
233399 05/13/11 06:27 manos Target: Screenshots
233398 05/13/11 06:18 qwanalysis Analysis: Run 12162 - Plots and Summary Table for 100k Events.
233397 05/13/11 06:10 cdaq Compton Run 22033 (standard): I=180uA, photon detector off
233396 05/13/11 06:09 cdaq Compton End of Run 22032 (standard):
233395 05/13/11 06:00 cdaq Compton Run 22032 (standard): I=180uA, photon detector off
233394 05/13/11 05:59 cdaq Compton End of Run 22031 (standard):
233393 05/13/11 05:59 cdaq Run 12162: LH2 production at 180 uA
233392 05/13/11 05:58 cdaq End of Run 12161:
233391 05/13/11 05:35 manos Electron detector communication error
233390 05/13/11 05:32 cdaq Compton Run 22031 (standard): I=180uA, photon detector off
233389 05/13/11 05:28 cdaq Compton End of Run 22030 (standard):
233388 05/13/11 05:03 qwanalysis Analysis: Run 12161 - Plots and Summary Table for 100k Events.
233387 05/13/11 04:49 cdaq Run 12161: LH2 production at 180 uA
233386 05/13/11 04:48 cdaq End of Run 12160:
233385 05/13/11 04:43 manos Compton: Turned off photon detector HV
233384 05/13/11 04:23 cdaq Compton Run 22030 (standard): I=180uA, BGO 1650 V,
233383 05/13/11 04:22 manos Compton: No power in cavity? And e-det moved in BEAM position
233382 05/13/11 04:16 cdaq Compton End of Run 22029 (standard):
233381 05/13/11 03:55 rajotte Weird shape of detector yield (after beam down)
233380 05/13/11 03:50 qwanalysis Analysis: Run 12160 - Plots and Summary Table for 100k Events.
233379 05/13/11 03:44 rajotte Qtor trip and reset
233378 05/13/11 03:37 cdaq Run 12160: LH2 production at 180 uA
233377 05/13/11 03:37 cdaq Compton Run 22029 (standard): I=180uA, BGO 1600 V,
233376 05/13/11 03:33 cdaq Compton End of Run 22028 (standard):
233375 05/13/11 03:17 cdaq End of Run 12159:
233374 05/13/11 03:02 cdaq Compton Run 22028 (standard): I=180uA, BGO 1600 V,
233373 05/13/11 03:02 cdaq Compton End of Run 22027 (standard):
233372 05/13/11 02:27 qwanalysis Analysis: Run 12159 - Plots and Summary Table for 100k Events.
233371 05/13/11 02:13 cdaq Run 12159: LH2 production at 180 uA
233370 05/13/11 02:12 cdaq End of Run 12158:
233369 05/13/11 02:03 cdaq Compton Run 22027 (standard): I=180uA, BGO 1600 V,
233368 05/13/11 02:03 cdaq Compton End of Run 22026 (standard):
233367 05/13/11 01:37 manos Big charge asymmetry width, small scintillator and halo rates
233366 05/13/11 01:24 qwanalysis Analysis: Run 12158 - Plots and Summary Table for 100k Events.
233365 05/13/11 01:12 cdaq Compton Run 22026 (standard): I=180uA, BGO 1600 V,
233364 05/13/11 01:12 qwanalysis Analysis: Run 12157 - Plots and Summary Table for 100k Events.
233363 05/13/11 01:07 cdaq Run 12158: LH2 production at 180 uA
233362 05/13/11 01:06 cdaq End of Run 12157:
233361 05/13/11 00:59 rajotte HWP IN -> OUT
233360 05/13/11 00:53 cdaq Run 12157: LH2 production at 180 uA
233359 05/13/11 00:52 cdaq Run 12156 Pedestal Data
233358 05/13/11 00:51 cdaq End of Run 12156:
233357 05/13/11 00:50 cdaq Run 12156: pedestal
233356 05/13/11 00:46 cdaq End of Run 12155:
233355 05/13/11 00:45 cdaq Compton End of Run 22025 (standard):
233354 05/13/11 00:38 manos HAL 9000 reminded us to check Compton run
233353 05/13/11 00:27 cdaq Compton Run 22025 (standard): I=150uA, BGO 1600 V,
233352 05/13/11 00:27 vardan General Tools and HV GUI snapshots
233351 05/13/11 00:26 cdaq Compton End of Run 22024 (standard):
233350 05/13/11 00:22 cdaq Beam Time Accounting
233349 05/13/11 00:21 vardan Shift Summary: swing shift summary
233348 05/13/11 00:17 manos Bellows temp for new trajectory good at 150uA
233347 05/13/11 00:13 sxyang Target GUI and strip charts screenshots at start of swing shift
233346 05/13/11 00:08 qwanalysis Analysis: Run 12155 - Plots and Summary Table for 100k Events.
Thursday
233345 05/12/11 23:44 cdaq Run 12155: Jim Burchill's test
233344 05/12/11 23:44 rob set points during adc saturation test
233343 05/12/11 23:34 rob set points during Faraday cup calibration
233342 05/12/11 23:28 rob tee removed
233341 05/12/11 23:24 cdaq End of Run 12154:
233340 05/12/11 23:05 cdaq Run 12154: MD ADC saturation test
233339 05/12/11 23:03 rob md6+ tee'd to DVM at ADC input
233338 05/12/11 22:56 cdaq End of Run 12153:
233337 05/12/11 22:53 cdaq Compton Run 22024 (standard): I=180uA, BGO 1600 V,
233336 05/12/11 22:52 cdaq Compton End of Run 22023 (standard):
233335 05/12/11 22:39 cdaq Run 12153: faraday cup calibration
233334 05/12/11 22:36 cdaq End of Run 12152:
233333 05/12/11 22:36 cdaq Compton Run 22023 (standard): I=180uA, BGO 1600 V,
233332 05/12/11 22:35 cdaq Compton End of Run 22022 (standard):
233331 05/12/11 22:33 rob reduced beam current for "jim's test"
233330 05/12/11 21:58 qwanalysis Analysis: Run 12152 - Plots and Summary Table for 100k Events.
233329 05/12/11 21:51 Ramesh bcm5,6 study with bcm2 signal as their input
233328 05/12/11 21:46 vardan in preparation fos Jim's test run
233327 05/12/11 21:41 mack installed rad badges on MD focal plane, etc.
233326 05/12/11 21:41 sxyang changed the heater compensation bcm back to bcm2
233325 05/12/11 21:37 cdaq Run 12152: Jim Burchal's test run
233324 05/12/11 21:25 qwanalysis Analysis: Run 12151 - Plots and Summary Table for 100k Events.
233323 05/12/11 21:23 qwanalysis Analysis: Run 12150 - Plots and Summary Table for 100k Events.
233322 05/12/11 21:13 cdaq End of Run 12151:
233321 05/12/11 21:12 Pitt Spreadsheet of lumi neutral axis results
233320 05/12/11 21:09 cdaq Run 12151: BCM6 study at 180 uA
233319 05/12/11 21:05 cdaq End of Run 12150:
233318 05/12/11 21:04 vardan 180 uA on LH2 target for BCM5 studies
233317 05/12/11 21:02 cdaq Run 12150: BCM5 study at 180 uA
233316 05/12/11 20:58 vardan hall was in control access from 8PM to 8:35PM.
233315 05/12/11 20:53 cdaq Compton Run 22022 (standard): I=180uA, BGO 1600 V,
233314 05/12/11 20:52 cdaq Compton End of Run 22021 (standard):
233313 05/12/11 20:18 cdaq End of Run 12149:
233312 05/12/11 20:07 qwanalysis Analysis: Run 12149 - Plots and Summary Table for 100k Events.
233311 05/12/11 19:55 cdaq Run 12149: lumi neutral axis study
233310 05/12/11 19:44 qwanalysis Analysis: Run 12148 - Plots and Summary Table for 100k Events.
233309 05/12/11 19:42 cdaq End of Run 12148:
233308 05/12/11 19:39 qwanalysis Analysis: Run 12147 - Plots and Summary Table for 100k Events.
233307 05/12/11 19:39 cdaq Compton Run 22021 (standard): I=180uA, BGO 1650 V
233306 05/12/11 19:38 cdaq Compton End of Run 22020 (standard):
233305 05/12/11 19:37 leacock bellows temps for "flat" and "golden"
233304 05/12/11 19:36 leacock stable bellows temps for "flat" and "golden"
233303 05/12/11 19:35 cdaq Compton Run 22020 (standard): I=180uA, BGO 1600 V DAQ check
233302 05/12/11 19:33 qwanalysis Analysis: Run 12146 - Plots and Summary Table for 100k Events.
233301 05/12/11 19:32 cdaq Run 12148: lumi neutral axis study
233300 05/12/11 19:30 cdaq End of Run 12147:
233299 05/12/11 19:29 leacock stable bellows temps at flat trajectory
233298 05/12/11 19:27 qwanalysis Analysis: Run 12145 - Plots and Summary Table for 100k Events.
233297 05/12/11 19:27 cdaq Run 12147: lumi neutral axis study
233296 05/12/11 19:25 cdaq End of Run 12146:
233295 05/12/11 19:21 cdaq Run 12146: lumi neutral axis study
233294 05/12/11 19:20 cdaq Compton End of Run 22019 (standard):
233293 05/12/11 19:19 qwanalysis Analysis: Run 12144 - Plots and Summary Table for 100k Events.
233292 05/12/11 19:18 cdaq End of Run 12145:
233291 05/12/11 19:18 cdaq Compton Run 22019 (standard): I=180uA, BGO 1600 V DAQ check
233290 05/12/11 19:15 cdaq Run 12145: lumi neutral axis study
233289 05/12/11 19:13 qwanalysis Analysis: Run 12143 - Plots and Summary Table for 100k Events.
233288 05/12/11 19:11 cdaq End of Run 12144:
233287 05/12/11 19:10 leacock bellows temps at bpm val 7
233286 05/12/11 19:08 cdaq Run 12144: lumi neutral axis study
233285 05/12/11 19:05 cdaq End of Run 12143:
233284 05/12/11 19:01 cdaq Run 12143: lumi neutral axis study
233283 05/12/11 19:01 cdaq End of Run 12142:
233282 05/12/11 19:00 qwanalysis Analysis: Run 12141 - Plots and Summary Table for 100k Events.
233281 05/12/11 18:56 cdaq Run 12142: lumi neutral axis study
233280 05/12/11 18:55 qwanalysis Analysis: Run 12140 - Plots and Summary Table for 100k Events.
233279 05/12/11 18:51 cdaq End of Run 12141:
233278 05/12/11 18:49 leacock bellows temps over time (beam angle)
233277 05/12/11 18:48 cdaq Run 12141: lumi neutral axis study
233276 05/12/11 18:46 qwanalysis Analysis: Run 12139 - Plots and Summary Table for 100k Events.
233275 05/12/11 18:45 cdaq End of Run 12140:
233274 05/12/11 18:42 cdaq Run 12140: lumi neutral axis study
233273 05/12/11 18:40 qwanalysis Analysis: Run 12138 - Plots and Summary Table for 100k Events.
233272 05/12/11 18:38 cdaq End of Run 12139:
233271 05/12/11 18:34 cdaq Run 12139: lumi neutral axis study
233270 05/12/11 18:32 cdaq End of Run 12138:
233269 05/12/11 18:27 cdaq Run 12138: lumi neutral axis study
233268 05/12/11 18:27 qwanalysis Analysis: Run 12137 - Plots and Summary Table for 100k Events.
233267 05/12/11 18:26 leacock bellows temps bpm val 2
233266 05/12/11 18:23 cdaq End of Run 12137:
233265 05/12/11 18:22 leacock temp variations during a trip flat trajectory
233264 05/12/11 18:17 leacock bellows and W plug temps 150uA "flat" bpm value 1
233263 05/12/11 18:15 cdaq Run 12137: lumi neutral axis study
233262 05/12/11 18:11 qwanalysis Analysis: Run 12136 - Plots and Summary Table for 100k Events.
233261 05/12/11 18:10 qwanalysis Analysis: Run 12135 - Plots and Summary Table for 100k Events.
233260 05/12/11 18:04 qwanalysis Analysis: Run 12134 - Plots and Summary Table for 100k Events.
233259 05/12/11 18:02 cdaq End of Run 12136:
233258 05/12/11 17:58 cdaq Run 12136: lumi neutral axis study
233257 05/12/11 17:57 cdaq End of Run 12135:
233256 05/12/11 17:52 cdaq Run 12135: lumi neutral axis study
233255 05/12/11 17:52 kamyers Update to beamline bkgd studies notes
233254 05/12/11 17:52 qwanalysis Analysis: Run 12133 - Plots and Summary Table for 100k Events.
233253 05/12/11 17:50 cdaq End of Run 12134:
233252 05/12/11 17:48 brads re: firefox is not working on cdaql3 (works for me)
233251 05/12/11 17:46 cdaq Run 12134: lumi neutral axis study
233250 05/12/11 17:45 qwanalysis Analysis: Run 12132 - Plots and Summary Table for 100k Events.
233249 05/12/11 17:44 cdaq End of Run 12133:
233248 05/12/11 17:42 qwanalysis Analysis: Run 12131 - Plots and Summary Table for 100k Events.
233247 05/12/11 17:41 smithg Target: last night's power densities
233246 05/12/11 17:40 cdaq Run 12133: lumi neutral axis study
233245 05/12/11 17:36 cdaq End of Run 12132:
233244 05/12/11 17:35 Armstrong the BCM5/6 test is invasive
233243 05/12/11 17:34 qwanalysis Analysis: Run 12130 - Plots and Summary Table for 100k Events.
233242 05/12/11 17:33 cdaq Run 12132: lumi neutral axis study
233241 05/12/11 17:31 cdaq End of Run 12131:
233240 05/12/11 17:27 cdaq Run 12131: lumi neutral axis study
233239 05/12/11 17:26 qwanalysis Analysis: Run 12129 - Plots and Summary Table for 100k Events.
233238 05/12/11 17:25 cdaq End of Run 12130:
233237 05/12/11 17:24 sxyang firefox is not working on cdaql3
233236 05/12/11 17:21 cdaq Run 12130: lumi neutral axis study
233235 05/12/11 17:20 qwanalysis Analysis: Run 12128 - Plots and Summary Table for 100k Events.
233234 05/12/11 17:19 cdaq End of Run 12129:
233233 05/12/11 17:15 cdaq Run 12129: lumi neutral axis study
233232 05/12/11 17:12 cdaq End of Run 12128:
233231 05/12/11 17:07 cdaq Run 12128: lumi neutral axis study
233230 05/12/11 17:07 qwanalysis Analysis: Run 12126 - Plots and Summary Table for 100k Events.
233229 05/12/11 17:00 cdaq End of Run 12127:
233228 05/12/11 16:50 benesch Beam: better screen captures for dispersive optics
233227 05/12/11 16:49 cdaq Run 12127: lumi neutral axis study
233226 05/12/11 16:48 cdaq End of Run 12126:
233225 05/12/11 16:48 leacock ramp rate changed from 1uA/s to 5uA/s
233224 05/12/11 16:42 leacock bellows temps and W plug temp diff with "flat" trajectory
233223 05/12/11 16:33 cdaq Run 12126: lumi neutral axis study
233222 05/12/11 16:30 sxyang change the heater compensation bcm
233221 05/12/11 16:25 rakithab CAEN HV setting and general tools snapshots
233220 05/12/11 16:11 cdaq Run 12125 Pedestal Data
233219 05/12/11 16:08 rakithab Shift Summary: Day Shift summary
233218 05/12/11 16:07 cdaq Beam Time Accounting
233217 05/12/11 16:04 cdaq End of Run 12125:
233216 05/12/11 16:02 cdaq Run 12125: pedestal
233215 05/12/11 16:00 cdaq End of Run 12124:
233214 05/12/11 15:53 Pitt Lumi neutral axis study plan - modifications
233213 05/12/11 15:52 leacock Y 6mm to 7mm (negative corrector)
233212 05/12/11 15:40 leacock halo rates as we move the beam on the plug in Y
233211 05/12/11 15:36 leacock corrector +2800 in Y ~7mm offset. we are hitting the plug
233210 05/12/11 15:29 cdaq Run 12124: W plug Y Scan
233209 05/12/11 15:25 cdaq Run 12123 Pedestal Data
233208 05/12/11 15:20 kamyers Analysis: recreated missing pedestal files
233207 05/12/11 15:19 cdaq End of Run 12123:
233206 05/12/11 15:18 cdaq Run 12123: pedestal run
233205 05/12/11 15:18 benesch Beam: beam during energy measurement and early this afternoon.
233204 05/12/11 15:16 leacock current doubled while we were doing the W plug test
233203 05/12/11 15:14 cdaq End of Run 12122:
233202 05/12/11 15:11 Ramesh plan for bcm5,6 test using bcm2 signal
233201 05/12/11 15:02 cdaq Run 12121 Pedestal Data
233200 05/12/11 14:49 leacock we are hitting the plug at +6mm
233199 05/12/11 14:42 cdaq Run 12122: W plug X scan
233198 05/12/11 14:34 leacock screenshot orbit lock OFF
233197 05/12/11 14:33 leacock screenshot at the start of the W plug test
233196 05/12/11 14:31 saw Beam: Followup to diffuser chiller water issue
233195 05/12/11 14:26 cdaq End of Run 12121:
233194 05/12/11 14:25 cdaq Run 12121: target out pedestal
233193 05/12/11 14:24 Pitt/Leacock Test plan for "lumi neutral axis study"
233192 05/12/11 14:20 rakithab Analysis: Moller Polarization Results
233191 05/12/11 13:28 rakithab Moller backout
233190 05/12/11 13:21 cdaq Compton End of Run 22018 (standard):
233189 05/12/11 13:04 cdaq Moller Run 1241: IHWP=IN leakage check
233188 05/12/11 13:02 cdaq Moller Run 1240: IHWP=IN Production
233187 05/12/11 12:50 cdaq Moller Run 1239: IHWP=IN Production
233186 05/12/11 12:49 cdaq Moller Run 1238: IHWP=IN Production
233185 05/12/11 12:40 cdaq Moller Run 1237: IHWP=IN Production
233184 05/12/11 12:23 gaskell FlipPC output
233183 05/12/11 12:23 cdaq Moller Run 1235: IHWP=IN Production
233182 05/12/11 12:10 cdaq Moller Run 1234: IHWP=OUT Production Q3 at 132A
233181 05/12/11 11:59 cdaq Moller Run 1233: IHWP=OUT Production Q3 at 132A
233180 05/12/11 11:57 cdaq Moller Run 1232: IHWP=OUT Production Q3 at 132A
233179 05/12/11 11:54 cdaq Moller Run 1231: IHWP=OUT tune check at Q3 = 132A
233178 05/12/11 11:43 cdaq Moller Run 1230: IHWP=OUT Production
233177 05/12/11 11:39 cdaq Moller Run 1229: IHWP=OUT Moller tune check Q3 at 131
233176 05/12/11 11:36 cdaq Moller Run 1228: IHWP=OUT Moller tune check
233175 05/12/11 11:28 gaskell Hall leader authorizes running until tomorrow
233174 05/12/11 11:07 gaskell added water to dump diffuser chiller
233173 05/12/11 10:58 rakithab Beam Dump diffuser FSD trip cleared after filled up chiller with more water
233172 05/12/11 10:14 rakithab Beam Dump diffuser FSD trip. Request Controlled Access and Ran-con support.
233171 05/12/11 09:47 gaskell Duration of CW beam on LH2 with no raster
233170 05/12/11 09:41 pking Analysis: Who removed the two missing pedestal ranges for MD and lumi?
233169 05/12/11 09:26 Jiawei Target: correct attachment
233168 05/12/11 09:21 cdaq Moller Run 1227: DAQ test
233167 05/12/11 09:19 Jiawei Target: target is out of beam for the moller measurement
233166 05/12/11 09:17 rakithab Moller Set-up
233165 05/12/11 09:10 rakithab Injector parameters before Moller
233164 05/12/11 09:03 rakithab BMod OFF for the moller
233163 05/12/11 09:02 cdaq End of Run 12120:
233162 05/12/11 08:40 rakithab Turned ON Beam Modulation
233161 05/12/11 08:23 Jiawei Target: Screen shots at the beginning of day shift
233160 05/12/11 08:11 qwanalysis Analysis: Run 12120 - Plots and Summary Table for 100k Events.
233159 05/12/11 08:05 cdaq Beam Time Accounting
233158 05/12/11 08:03 rajotte Shift Summary: OWL Shift Summary
233157 05/12/11 07:56 cdaq Run 12120: LH2 production
233156 05/12/11 07:56 cdaq End of Run 12119:
233155 05/12/11 07:47 Mitra Target screens snapshot
233154 05/12/11 07:42 cdaq Compton Run 22018 (standard): I=180uA, BGO 1600 V,
233153 05/12/11 07:38 cdaq Compton End of Run 22017 (standard):
233152 05/12/11 07:20 Armstrong Beam: Late entry - energy measurement results
233151 05/12/11 07:12 rajotte general tools & HV
233150 05/12/11 07:07 qwanalysis Analysis: Run 12119 - Plots and Summary Table for 100k Events.
233149 05/12/11 06:53 cdaq Run 12119: LH2 production
233148 05/12/11 06:53 cdaq End of Run 12118:
233147 05/12/11 06:36 cdaq Compton Run 22017 (standard): I=180uA, BGO 1600 V,
233146 05/12/11 06:36 cdaq Compton End of Run 22016 (standard):
233145 05/12/11 06:14 qwanalysis Analysis: Run 12118 - Plots and Summary Table for 100k Events.
233144 05/12/11 05:53 cdaq Run 12118: LH2 production
233143 05/12/11 05:52 cdaq Run 12117 Pedestal Data
233142 05/12/11 05:49 cdaq End of Run 12117:
233141 05/12/11 05:48 cdaq Run 12117: Pedestal
233140 05/12/11 05:47 cdaq End of Run 12116:
233139 05/12/11 05:33 cdaq Compton Run 22016 (standard): I=180uA, BGO 1600 V,
233138 05/12/11 05:08 qwanalysis Analysis: Run 12116 - Plots and Summary Table for 100k Events.
233137 05/12/11 04:56 qwanalysis Analysis: Run 12115 - Plots and Summary Table for 100k Events.
233136 05/12/11 04:50 cdaq Run 12116: LH2 production
233135 05/12/11 04:49 cdaq End of Run 12115:
233134 05/12/11 04:49 Mitra Target screens snapshot
233133 05/12/11 04:45 rajotte HWP IN -> OUT
233132 05/12/11 04:42 cdaq Run 12115: LH2 production
233131 05/12/11 04:39 cdaq Compton End of Run 22015 (standard):
233130 05/12/11 04:39 cdaq End of Run 12114:
233129 05/12/11 04:38 Mitra HV Controls snapshot
233128 05/12/11 04:37 Mitra General Tools snapshot
233127 05/12/11 04:01 qwanalysis Analysis: Run 12114 - Plots and Summary Table for 100k Events.
233126 05/12/11 03:45 cdaq Compton Run 22015 (standard): I=180uA, BGO 1600 V,
233125 05/12/11 03:45 cdaq Compton End of Run 22014 (standard):
233124 05/12/11 03:45 cdaq Run 12114: LH2 production 180
233123 05/12/11 03:44 cdaq End of Run 12113:
233122 05/12/11 03:29 qwanalysis Analysis: Run 12113 - Plots and Summary Table for 100k Events.
233121 05/12/11 02:53 cdaq Compton Run 22014 (standard): I=180uA, BGO 1600 V,
233120 05/12/11 02:52 cdaq Compton End of Run 22013 (standard):
233119 05/12/11 02:43 cdaq Run 12113: LH2 production 180
233118 05/12/11 02:42 cdaq End of Run 12112:
233117 05/12/11 02:02 cdaq Compton Run 22013 (standard): I=180uA, BGO 1600 V,
233116 05/12/11 02:00 qwanalysis Analysis: Run 12112 - Plots and Summary Table for 100k Events.
233115 05/12/11 01:57 rajotte general tools & HV
233114 05/12/11 01:47 rajotte Beam back after requested harp scan
233113 05/12/11 01:43 cdaq Run 12112: LH2 production 180
233112 05/12/11 01:38 rajotte Moving e-detector back in
233111 05/12/11 01:35 cdaq Compton End of Run 22012 (standard):
233110 05/12/11 00:46 narayan Shift Summary: Swing Shift Summary
233109 05/12/11 00:44 rajotte Requesting harp scan to MCC
233108 05/12/11 00:29 qwanalysis Analysis: Run 12111 - Plots and Summary Table for 100k Events.
233107 05/12/11 00:14 jhoskins restarted TS0 and CODA
233106 05/12/11 00:12 cdaq Run 12111: LH2 production: y phase space test
233105 05/12/11 00:08 jhoskins EPICS communication error
233104 05/12/11 00:07 cdaq Beam Time Accounting
233103 05/12/11 00:06 smithg Target: Listen to your alarms. Use your heads!
233102 05/12/11 00:04 cdaq End of Run 12110:
Wednesday
233101 05/11/11 23:56 pking Analysis: Raster QDC channels were not decoded properly in creating these plots
233100 05/11/11 23:42 cdaq Run 12110: LH2 production: y phase space test
233099 05/11/11 23:38 cdaq Compton Run 22012 (standard): I=180uA, BGO 1600 V, not useful for eDet
233098 05/11/11 23:33 smithg Target: never EVER put unrastered beam on the LH2 target!
233097 05/11/11 23:31 pking Analysis: Found problem with raster channel map; reverted to the 1.08rc3 version of the raster channel map
233096 05/11/11 23:26 jhoskins FYI bmod was on during E-measurement
233095 05/11/11 23:23 qwanalysis Analysis: Run 12107 - Plots and Summary Table for 100k Events.
233094 05/11/11 23:21 jhoskins Starting bmod phase space test
233093 05/11/11 23:17 cdaq Run 12109: LH2 production
233092 05/11/11 23:16 narayan temperatures during Swing shift
233091 05/11/11 23:09 jhlee reboot vmec18 due to caget error
233090 05/11/11 22:54 vardan Target: 5uA unrasterd beam
233089 05/11/11 22:19 narayan shift checklist snapshot
233088 05/11/11 22:18 vardan Target: low raster current alarm
233087 05/11/11 22:18 narayan Compton: phDet HV turned off during energy measurement
233086 05/11/11 22:14 cdaq Compton Run 22011 (standard): junk
233085 05/11/11 22:13 cdaq Compton End of Run 22011 (standard):
233084 05/11/11 22:10 narayan Status: Energy Measurement underway
233083 05/11/11 22:06 vardan Target: correction: not modulation but compensation
233082 05/11/11 21:56 cdaq Compton End of Run 22010 (standard):
233081 05/11/11 21:52 cdaq Compton Run 22010 (standard): I=5 uA, BGO 1600 V, energy measurement in progress
233080 05/11/11 21:51 cdaq Run 12108: energy measurement in progress, 5 uA beam currently
233079 05/11/11 21:44 cdaq Compton End of Run 22009 (standard):
233078 05/11/11 21:40 cdaq End of Run 12107:
233077 05/11/11 21:38 narayan Target: temporarily increased hihi limit on beam current
233076 05/11/11 20:42 cdaq Compton Run 22009 (standard): I=180uA, BGO 1600 V,
233075 05/11/11 20:41 cdaq Compton End of Run 22008 (standard):
233074 05/11/11 20:40 cdaq Run 12107: LH2 production
233073 05/11/11 20:38 cdaq End of Run 12106:
233072 05/11/11 20:29 qwanalysis Analysis: Run 12106 - Plots and Summary Table for 100k Events.
233071 05/11/11 20:18 narayan Compton: edet lowered to 'BEAM' again
233070 05/11/11 19:40 cdaq Compton Run 22008 (standard): I=180uA, BGO 1600 V,
233069 05/11/11 19:39 cdaq Compton End of Run 22007 (standard):
233068 05/11/11 19:37 cdaq Run 12106: LH2 production again
233067 05/11/11 19:36 Jiawei back out the raster frequency test
233066 05/11/11 19:19 cdaq Raster Map and BPMs : Run 12105, event range 175000 - 195000
233065 05/11/11 19:16 cdaq End of Run 12105:
233064 05/11/11 19:13 cdaq Run 12105: raster map of LH2 @nominal raster freq.
233063 05/11/11 18:57 Jiawei Turn on the scanner HV to do the raster map for Paul's test
233062 05/11/11 18:53 Jiawei start doing Paul's raster frequency test
233061 05/11/11 18:45 qwanalysis Analysis: Run 12104 - Plots and Summary Table for 100k Events.
233060 05/11/11 18:45 donjones Compton: HV set to 1600V
233059 05/11/11 18:43 cdaq Compton Run 22007 (standard): I=180uA, BGO 1600 V,
233058 05/11/11 18:41 narayan charge feedback found off
233057 05/11/11 18:38 cdaq Compton End of Run 22006 (standard):
233056 05/11/11 18:30 vardan Target: beam current limits zeroed
233055 05/11/11 18:27 vardan Target: beam current alarm
233054 05/11/11 18:25 Ramesh bcm1,2 signals into bcm5,6 test: entry 1
233053 05/11/11 18:21 Jiawei redo the target boiling test by changing the raster size at 180muA (BCM1)
233052 05/11/11 18:14 cdaq Run 12104: target boiling test of raster scan at 180 muA
233051 05/11/11 18:11 vardan Target: HBH beam modulation enabled
233049 05/11/11 17:59 cdaq Run 12103: junk
233048 05/11/11 17:55 cdaq End of Run 12102:
233047 05/11/11 17:46 cdaq Run 12102: bcm 1/2 cables switched bcm 5/6, 2*30 dB attenuators added
233046 05/11/11 17:45 cdaq Compton Run 22006 (standard): I=160uA, BGO 1650 V,
233045 05/11/11 17:42 cdaq End of Run 12101:
233044 05/11/11 17:38 cdaq Compton End of Run 22005 (standard):
233043 05/11/11 17:32 cdaq Compton Run 22005 (standard): I=160uA, BGO 1650 V,
233042 05/11/11 17:31 cdaq Run 12101: bcm 1/2 cables switched bcm 5/6
233041 05/11/11 17:29 cdaq End of Run 12100:
233040 05/11/11 17:27 cdaq Run 12100: BCM 1 & 2 being worked on, real beam delivered is 160 uA
233039 05/11/11 17:25 vardan Target: on the HPH beam compensation on/off procedure
233038 05/11/11 17:15 cdaq End of Run 12099:
233037 05/11/11 17:10 cdaq Beam Time Accounting
233036 05/11/11 17:10 pking Test plan: Modify raster frequencies to give more uniform coverage of the raster square
233035 05/11/11 17:09 cdaq Run 12099: baseline run before swapping bcm1/2 and 5/6 cables at 160 muA
233034 05/11/11 17:09 cdaq End of Run 12098:
233033 05/11/11 17:06 Mack/Jiawei start the bcm 1/2 and 5/6 swap test
233032 05/11/11 17:06 cdaq Run 12098: baseline run before swapping bcm1/2 and 5/6 cables at 160 muA
233031 05/11/11 17:01 vardan Target: HPH beam compensation off
233030 05/11/11 16:55 beaufait qtor reset
233029 05/11/11 16:51 narayan Status: QTOR ramping up finally, coming out of Controlled access
233028 05/11/11 16:32 vardan Target: GUI and strip charts screenshots at the start of swing shift
233027 05/11/11 16:20 sxyang day shift summary
233026 05/11/11 16:05 cdaq Compton End of Run 22004 (standard):
233025 05/11/11 15:32 Jiawei QTor Tripped
233024 05/11/11 15:21 cdaq End of Run 12097:
233023 05/11/11 14:57 qwanalysis Analysis: Run 12097 - Plots and Summary Table for 100k Events.
233022 05/11/11 14:56 Jiawei switched the 2nd part of the 480Hz test to raster size scan at 960Hz
233021 05/11/11 14:49 Jiawei late entry: everything set back to normal 960Hz setup
233020 05/11/11 14:45 cdaq Run 12097: 960Hz target boiling test -- raster size scan at 180muA
233019 05/11/11 14:39 Armstrong Compton: end run, Event Builder crash....
233018 05/11/11 14:28 Jiawei helicity board back to 960Hz
233017 05/11/11 14:27 cdaq Compton Run 22004 (standard): I=180uA, BGO 1650 V,
233016 05/11/11 14:24 kamyers Notes from beamline bkgd studies
233015 05/11/11 14:22 cdaq End of Run 12096:
233014 05/11/11 14:22 cdaq Compton End of Run 22003 (standard):
233013 05/11/11 14:16 cdaq Run 12096: 480Hz target boiling test by varing the pump speed
233012 05/11/11 14:09 cdaq Compton Run 22003 (standard): I=180uA, BGO 1650 V,
233011 05/11/11 14:09 cdaq End of Run 12095:
233010 05/11/11 14:05 cdaq Compton End of Run 22003 (standard):
233009 05/11/11 13:44 qwanalysis Analysis: Run 12095 - Plots and Summary Table for 100k Events.
233008 05/11/11 13:29 cdaq Run 12095: 480Hz target boiling test by varing the pump speed
233007 05/11/11 13:28 sxyang screenshots of general tools and hv guis
233006 05/11/11 13:25 sxyang beam might be off for some time
233005 05/11/11 13:24 Jiawei run 12094 is junk
233004 05/11/11 13:24 cdaq End of Run 12094:
233003 05/11/11 13:19 cdaq Run 12094: 480Hz target boiling test by varing the pump speed
233002 05/11/11 13:17 Armstrong More on beam quality
233001 05/11/11 13:02 Jiawei MCC has some vacuum valve problem, we are waiting for the beam back to finish the test
233000 05/11/11 13:01 donjones Compton: beam off rates linked to Hall A mode
232999 05/11/11 12:52 qwanalysis Analysis: Run 12092 - Plots and Summary Table for 100k Events.
232998 05/11/11 12:43 cdaq End of Run 12093:
232997 05/11/11 12:42 qwanalysis Analysis: Run 12091 - Plots and Summary Table for 100k Events.
232996 05/11/11 12:40 cdaq Run 12093: short 480Hz target boiling test at 170muA 4x4 octo-quad pattern
232995 05/11/11 12:39 cdaq End of Run 12092:
232994 05/11/11 12:38 qwanalysis Analysis: Run 12090 - Plots and Summary Table for 100k Events.
232993 05/11/11 12:34 cdaq Run 12092: 480Hz target boiling test at 170muA 4x4 octo-quad pattern
232992 05/11/11 12:33 cdaq End of Run 12091:
232991 05/11/11 12:31 qwanalysis Analysis: Run 12089 - Plots and Summary Table for 100k Events.
232990 05/11/11 12:30 Armstrong Beam quality much improved
232989 05/11/11 12:28 cdaq Run 12091: 480Hz target boiling test at 170muA 4x4 octet pattern
232988 05/11/11 12:27 cdaq End of Run 12090:
232987 05/11/11 12:25 cdaq Run 12090: 480Hz target boiling test at 170muA 4x4 octet pattern
232986 05/11/11 12:21 cdaq End of Run 12089:
232985 05/11/11 12:16 cdaq Run 12089: 480Hz target boiling test at 170muA 4x4 quartet pattern
232984 05/11/11 12:15 cdaq End of Run 12088:
232983 05/11/11 12:09 Jiawei run 12087 is junk.
232982 05/11/11 12:08 Adesh Snapshot of Helicity Control Board
232981 05/11/11 12:08 cdaq Run 12088: 480Hz target boiling test at 170muA 4x4 quartet pattern
232980 05/11/11 12:06 cdaq End of Run 12087:
232979 05/11/11 12:05 cdaq Run 12087: 480Hz target boiling test at
232978 05/11/11 12:04 Jiawei start the 480Hz target boiling test
232977 05/11/11 11:58 cdaq End of Run 12086:
232976 05/11/11 11:29 paschke Analysis: Detector widths at 180 uA
232975 05/11/11 11:20 Armstrong Beam back; charge asynnetry width better
232974 05/11/11 11:18 qwanalysis Analysis: Run 12086 - Plots and Summary Table for 100k Events.
232973 05/11/11 11:06 cdaq Run 12086: LH2 production at 180uA
232972 05/11/11 11:05 cdaq Compton Run 22003 (standard): I=180uA, BGO 1650 V,
232971 05/11/11 11:00 cdaq End of Run 12084:
232970 05/11/11 10:51 sxyang beam is back
232969 05/11/11 10:49 cdaq Run 12084: LH2 production at 180uA
232968 05/11/11 10:26 Armstrong still a while for beam back
232967 05/11/11 10:24 covrig Target: I, gremlin
232966 05/11/11 10:05 Armstrong Target: someone changed 15 K J/T?
232965 05/11/11 09:51 cdaq End of Run 12083:
232964 05/11/11 09:48 Armstrong more on beam quality
232963 05/11/11 09:37 Armstrong Link to entry by Jay
232962 05/11/11 09:28 Armstrong correction re: injector run
232961 05/11/11 09:22 saw Tungsten plug power
232960 05/11/11 08:59 cdaq Compton End of Run 22002 (standard):
232959 05/11/11 08:59 gaskell Compton: photon HV increased to 1650 for run 21996
232958 05/11/11 08:59 Armstrong Target screens
232957 05/11/11 08:58 birchall Analysis: High nonlinearity in runs 12076 - 12079
232956 05/11/11 08:57 Armstrong Unser says we were at 177 muA
232955 05/11/11 08:56 gaskell Compton: HV troubleshooting
232954 05/11/11 08:50 gaskell Compton: electron detector in garage, photon detector off
232953 05/11/11 08:43 sxyang injector run 2050413 is ended
232952 05/11/11 08:42 paschke Compton: compton photon signal too high?
232951 05/11/11 08:36 cdaq Run 12083: pedestal run
232950 05/11/11 08:35 Armstrong Beam off for MCC to optimize beam quality
232949 05/11/11 08:31 cdaq End of Run 12082:
232948 05/11/11 08:24 sxyang stopped run 12082 early
232947 05/11/11 08:20 qwanalysis Analysis: Run 12082 - Plots and Summary Table for 100k Events.
232946 05/11/11 08:18 Armstrong Target happy at 180 muA as measured on MPS BCM
232945 05/11/11 08:10 cdaq Beam Time Accounting
232944 05/11/11 08:09 Dutta Shift Summary: OWL shift summary 05/11/11
232943 05/11/11 08:08 Mitra Target snapshots
232942 05/11/11 08:07 Dutta Started Injector run 2418
232941 05/11/11 07:50 cdaq Compton Run 22002 (standard): I=180uA, BGO 1650 V,
232940 05/11/11 07:49 cdaq Run 12082: LH2 production at 180uA
232939 05/11/11 07:48 cdaq End of Run 12081:
232938 05/11/11 07:48 cdaq Compton End of Run 22001 (standard):
232937 05/11/11 06:59 qwanalysis Analysis: Run 12081 - Plots and Summary Table for 100k Events.
232936 05/11/11 06:45 cdaq Compton Run 22001 (standard): I=180uA, BGO 1650 V,
232935 05/11/11 06:44 cdaq Run 12081: LH2 production at 180uA
232934 05/11/11 06:44 cdaq Compton End of Run 22000 (standard):
232933 05/11/11 06:44 cdaq End of Run 12080:
232932 05/11/11 05:57 qwanalysis Analysis: Run 12080 - Plots and Summary Table for 100k Events.
232931 05/11/11 05:47 Dutta Run number discrepancy fixed
232930 05/11/11 05:45 cdaq Run 12080: LH2 production at 180uA
232929 05/11/11 05:44 cdaq Compton Run 22000 (standard): I=180uA, BGO 1650 V,
232928 05/11/11 05:43 cdaq Compton End of Run 21999 (standard):
232927 05/11/11 05:43 cdaq End of Run 12079:
232926 05/11/11 05:31 Mitra Target screens
232925 05/11/11 05:00 Mitra HV Controls snapshot
232924 05/11/11 04:59 Mitra General Tools snapshot
232923 05/11/11 04:43 qwanalysis Analysis: Run 12079 - Plots and Summary Table for 100k Events.
232922 05/11/11 04:26 cdaq Compton Run 21999 (standard): I=180uA, BGO 1650 V,
232921 05/11/11 04:20 cdaq Run 12079: LH2 production at 180uA
232920 05/11/11 04:20 cdaq Compton End of Run 21998 (standard):
232919 05/11/11 04:19 cdaq End of Run 12078:
232918 05/11/11 04:19 cdaq Compton Run 21998 (standard): I=180uA, BGO 1650 V,
232917 05/11/11 03:53 cdaq Compton End of Run 21997 (standard):
232916 05/11/11 03:36 Dutta CODA crashed
232915 05/11/11 03:31 qwanalysis Analysis: Run 12078 - Plots and Summary Table for 100k Events.
232914 05/11/11 03:17 cdaq Run 12078: LH2 production at 180uA
232913 05/11/11 03:09 cdaq Run 12077: LH2 production at 180uA
232912 05/11/11 02:24 Dutta Late entry: BMod was off in the begining of run 21076
232911 05/11/11 02:11 Dutta Analysis: A_q widths are too high
232910 05/11/11 02:07 qwanalysis Analysis: Run 12077 - Plots and Summary Table for 100k Events.
232909 05/11/11 01:54 cdaq Compton Run 21997 (standard): I=180uA, BGO 1650 V,
232908 05/11/11 01:54 cdaq Run 12076: LH2 production at 180uA
232907 05/11/11 01:52 cdaq End of Run 12076:
232906 05/11/11 01:52 cdaq Compton End of Run 21996 (standard):
232905 05/11/11 01:22 cdaq Compton Run 21996 (standard): I=180uA, BGO 1650 V,
232904 05/11/11 01:17 qwanalysis Analysis: Run 12076 - Plots and Summary Table for 100k Events.
232903 05/11/11 01:07 narayan Compton: I@180, scintillator rates
232902 05/11/11 01:02 qwanalysis Analysis: Run 12064 - Plots and Summary Table for 100k Events.
232901 05/11/11 01:00 Dutta 180 uA on target
232900 05/11/11 00:50 cdaq Run 12076: LH2 production at 180uA
232899 05/11/11 00:48 cdaq End of Run 12075:
232898 05/11/11 00:47 narayan Shift Summary: Swing Shift Summary
232897 05/11/11 00:38 narayan Shift Summary: Swing Shift Summary
232896 05/11/11 00:38 narayan Shift Summary: Swing Shift Summary
232895 05/11/11 00:30 kamyers Analysis: Preliminary beamline background estimates
232894 05/11/11 00:29 Dutta Beam: Halo rates too high: request an auto-steer
232893 05/11/11 00:29 Mitra Changed bellowstemp3 High and HiHi limits
232892 05/11/11 00:26 narayan background detector HV off
232891 05/11/11 00:21 cdaq Run 12075: LH2 at 150 uA
232890 05/11/11 00:17 cdaq End of Run 12074:
232889 05/11/11 00:13 cdaq Run 12074: Beamline background test:, QTOR 8921, LH2 target,
232888 05/11/11 00:13 cdaq Beam Time Accounting
232887 05/11/11 00:11 cdaq End of Run 12073:
232886 05/11/11 00:10 mack tale of the position instabilities at the beginning of swing shift
232885 05/11/11 00:01 buddhini Target: Moved to LH2.
232884 05/11/11 00:00 cdaq Run 12073: Beamline background test:, QTOR 6700, LH2 target,
Tuesday
232883 05/10/11 23:57 cdaq End of Run 12072:
232882 05/10/11 23:53 cdaq Run 12072: Beamline background test:, QTOR 8921, Al 4% DS,
232881 05/10/11 23:51 cdaq End of Run 12071:
232880 05/10/11 23:48 cdaq Run 12071: Beamline background test:, QTOR 6700, Al 4% DS,
232879 05/10/11 23:47 buddhini Target: Moved to DS 4% Al target
232878 05/10/11 23:46 cdaq End of Run 12070:
232877 05/10/11 23:38 cdaq Run 12070: Beamline background test: LH2, QTOR 6700
232876 05/10/11 23:38 kamyers Notes from Jiawei's QTOR beamline shielding runs
232875 05/10/11 23:37 cdaq End of Run 12069:
232874 05/10/11 23:32 cdaq Run 12069: Beamline background test: Al 2% US target
232873 05/10/11 23:31 Jiawei octant 7 of collimator II is unblocked and all the lead bticks are removed from Al tray around US QTOR
232872 05/10/11 23:09 narayan Compton: ph-Det HV increased to 1650
232871 05/10/11 22:58 cdaq End of Run 12068:
232870 05/10/11 22:54 cdaq Run 12068: Beamline background test: US 2% Al target, QTOR 8921
232869 05/10/11 22:53 cdaq Run 12067 Pedestal Data
232868 05/10/11 22:53 buddhini Target: Moved to US 2% Al target
232867 05/10/11 22:50 cdaq Run 12067: Beamline background test: pedestal
232866 05/10/11 22:49 cdaq End of Run 12066:
232865 05/10/11 22:47 narayan shift checklist snapshot
232864 05/10/11 22:44 cdaq Run 12066: Beamline background test: LH2 target, 150muA, 8921A
232863 05/10/11 22:43 cdaq Compton End of Run 21995 (standard):
232862 05/10/11 22:40 cdaq Run 12065 Pedestal Data
232861 05/10/11 22:38 cdaq End of Run 12065:
232860 05/10/11 22:37 cdaq Run 12065: Beamline background test: pedestal
232859 05/10/11 22:36 narayan Status: shimmed up the lead brick by 1"
232858 05/10/11 22:10 narayan Status: requested controlled access
232857 05/10/11 22:05 cdaq End of Run 12064:
232856 05/10/11 21:59 buddhini Target: late entry: moved to LH2
232855 05/10/11 21:57 cdaq Run 12064: Beamline background test: LH2, 150muA, 8921A
232854 05/10/11 21:57 cdaq Compton Run 21995 (standard): I=150uA, BGO 1600 V, 3/3 electron trigger
232853 05/10/11 21:56 cdaq End of Run 12063:
232852 05/10/11 21:52 cdaq Run 12063: Beamline background test: LH2, 150muA, 8921A
232851 05/10/11 21:51 cdaq Run 12062 Pedestal Data
232850 05/10/11 21:50 cdaq End of Run 12062:
232849 05/10/11 21:49 cdaq Run 12062: pedestal
232848 05/10/11 21:46 cdaq End of Run 12061:
232847 05/10/11 21:42 cdaq Run 12061: Beamline background test: US 2% Al, 42 muA, 8921A
232846 05/10/11 21:34 cdaq Run 12060 Pedestal Data
232845 05/10/11 21:33 cdaq End of Run 12060:
232844 05/10/11 21:31 cdaq Run 12060: pedestal
232843 05/10/11 21:19 narayan Status: controlled access
232842 05/10/11 21:04 cdaq Compton End of Run 21994 (standard):
232841 05/10/11 20:58 cdaq End of Run 12059:
232840 05/10/11 20:57 cdaq Compton Run 21994 (standard): I=40uA, BGO 1600 V, 3/3 electron trigger
232839 05/10/11 20:56 cdaq Compton End of Run 21993 (standard):
232838 05/10/11 20:54 narayan halo rates during background studies
232837 05/10/11 20:54 cdaq Run 12059: Beamline background test: US Al 2%, 42 muA
232836 05/10/11 20:53 cdaq Run 12058 Pedestal Data
232835 05/10/11 20:52 cdaq End of Run 12058:
232834 05/10/11 20:52 buddhini Target: Moved to DS 2% Al target
232833 05/10/11 20:49 cdaq Run 12058: pedestal
232832 05/10/11 20:47 cdaq End of Run 12057:
232831 05/10/11 20:42 cdaq Run 12057: Beamline background test: LH2 target, QTOR 8921
232830 05/10/11 20:42 cdaq End of Run 12056:
232829 05/10/11 20:37 cdaq Compton Run 21993 (standard): I=150uA, BGO 1600 V, 3/3 electron trigger
232828 05/10/11 20:36 cdaq Run 12056: Beamline background test: LH2 target, QTOR 8921
232827 05/10/11 20:34 buddhini Target: Moved to LH2.
232826 05/10/11 20:32 cdaq Run 12055 Pedestal Data
232825 05/10/11 20:30 cdaq End of Run 12055:
232824 05/10/11 20:29 cdaq Run 12055: pedestal
232823 05/10/11 20:28 cdaq End of Run 12054:
232822 05/10/11 20:23 cdaq Run 12054: Beamline background test: 2% Al US, QTOR 8921
232821 05/10/11 20:09 narayan Status:
232820 05/10/11 20:08 cdaq Run 12053 Pedestal Data
232819 05/10/11 19:46 dalton Compton: Backed out of electron trigger
232818 05/10/11 19:39 cdaq Run 12053 Pedestal Data
232817 05/10/11 19:35 cdaq Run 12053: pedestal run #9
232816 05/10/11 19:33 cdaq Compton End of Run 21992 (standard):
232815 05/10/11 19:32 cdaq End of Run 12052:
232814 05/10/11 19:27 cdaq Compton Run 21992 (standard): I=40uA, BGO 1600 V, 3/3 electron trigger
232813 05/10/11 19:20 cdaq Compton Run 21991 (standard): I=40uA; BGO 1600 V; 3/3 electron trigger
232812 05/10/11 19:20 cdaq Run 12052: Beamline background test: 2% Al US, QTOR 6700
232811 05/10/11 19:17 cdaq Compton End of Run 21990 (standard):
232810 05/10/11 19:16 cdaq End of Run 12051:
232809 05/10/11 19:06 cdaq Compton Run 21990 (standard): I=40uA; BGO; 3/3 electron trigger for response function
232808 05/10/11 19:03 cdaq Compton End of Run 21989 (standard):
232807 05/10/11 19:03 cdaq Run 12051: Beamline background test: 2% Al US, QTOR 8921
232806 05/10/11 18:55 cdaq Compton Run 21989 (standard): I=170uA; electron detector HV off
232805 05/10/11 18:50 cdaq Run 12050 Pedestal Data
232804 05/10/11 18:49 cdaq Compton End of Run 21988 (standard):
232803 05/10/11 18:49 cdaq End of Run 12050:
232802 05/10/11 18:48 buddhini Target: Moved to US 2% Al target
232801 05/10/11 18:47 cdaq Run 12050: pedestal run #6
232800 05/10/11 18:46 cdaq End of Run 12049:
232799 05/10/11 18:34 cdaq Run 12049: Beamline background test: 4%DS Al, QTOR 8921
232798 05/10/11 18:31 cdaq End of Run 12048:
232797 05/10/11 18:26 cdaq Compton Run 21988 (standard): current scan HV=1700
232796 05/10/11 18:23 donjones Compton: changed HV channel to Compton 8
232795 05/10/11 18:19 cdaq Run 12048: Beamline background test: 4%DS Al, QTOR 6700
232794 05/10/11 18:16 narayan Status:
232793 05/10/11 18:15 cdaq Run 12047 Pedestal Data
232792 05/10/11 18:14 buddhini Target: Moved to DS 4% Al target
232791 05/10/11 18:13 cdaq End of Run 12047:
232790 05/10/11 18:11 cdaq Run 12047: Pedestal
232789 05/10/11 18:09 cdaq End of Run 12046:
232788 05/10/11 17:55 cdaq Run 12046: Beamline background test: LH2, QTOR 6700
232787 05/10/11 17:54 cdaq End of Run 12045:
232786 05/10/11 17:53 kamyers halo spikes and FFB corrector spikes
232785 05/10/11 17:40 donjones Compton: HV went to 2200 V when setpoint was 1700V
232784 05/10/11 17:38 cdaq Run 12045: Beamline background test: LH2, QTOR 8921
232783 05/10/11 17:37 cdaq Compton End of Run 21987 (standard):
232782 05/10/11 17:34 paschke Beam trips and PC flips
232781 05/10/11 17:23 narayan Status: halo rates brought down
232780 05/10/11 17:19 mack rebooting iochlc3 brought halo 3/4 rates up on the "wall" screen
232779 05/10/11 16:34 cdaq Beam Time Accounting
232778 05/10/11 16:19 donjones Compton: installed BGO detector
232777 05/10/11 16:16 cdaq End of Run 12044:
232776 05/10/11 16:13 kamyers bpm and epics scalers
232775 05/10/11 16:12 kamyers FFB corrector instability
232774 05/10/11 16:07 cdaq Compton Run 21987 (standard): I=150uA BGO HV=1700
232773 05/10/11 16:04 cdaq Run 12044: Beamline background test: LH2, QTOR 8921
232772 05/10/11 15:57 Armstrong Shift Summary: Day Shift summary - May 10 2011
232771 05/10/11 15:56 Armstrong Shift Summary: Day Shift summary - May 10 2011
232770 05/10/11 15:27 brads re: remove a symlink on cdaql7 (config was still invalid, should be correct now)
232769 05/10/11 15:16 cdaq End of Run 12043:
232768 05/10/11 14:56 Armstrong Firmware upgrade to allow 180 µA
232767 05/10/11 14:55 Armstrong Ready for beam
232766 05/10/11 14:51 cdaq Run 12043: Pedestal
232765 05/10/11 14:48 Armstrong Harp repair
232764 05/10/11 14:27 beaufait qtor flush
232763 05/10/11 14:22 rob remove a symlink on cdaql7
232762 05/10/11 12:10 Armstrong General Tools snapshot
232761 05/10/11 11:38 Armstrong Correction - still in beam studies
232760 05/10/11 11:26 Armstrong MCC calls - ready to start beam restore
232759 05/10/11 11:03 Armstrong QTor back on again
232758 05/10/11 10:49 Armstrong QTor turned off
232757 05/10/11 10:33 cdaq Compton End of Run 21986 (standard):
232756 05/10/11 10:30 cdaq Compton Run 21986 (standard): BGO pedestal HV=1600V
232755 05/10/11 10:29 cdaq Compton End of Run 21985 (standard):
232754 05/10/11 10:26 cdaq Compton Run 21985 (standard): BGO pedestal HV=1800V
232753 05/10/11 10:25 cdaq Compton End of Run 21984 (standard):
232752 05/10/11 10:19 cdaq Compton Run 21984 (standard): BGO pedestal HV=1700V
232751 05/10/11 10:04 mack little orange Pb wall is now blocking octant 7, collimator 2
232750 05/10/11 09:10 Armstrong QTor back!
232749 05/10/11 08:25 mack updated plugged octant 7 test plan
232748 05/10/11 08:03 cdaq Beam Time Accounting
232747 05/10/11 08:02 Dutta Shift Summary: OWL shift summary 05/10/11
232746 05/10/11 07:51 Armstrong Hall C survey done
232745 05/10/11 07:12 cdaq Compton End of Run 21983 (standard):
232744 05/10/11 06:57 cdaq Compton Run 21983 (standard): eDet Calib tests
232743 05/10/11 06:56 cdaq Compton End of Run 21982 (standard):
232742 05/10/11 06:43 cdaq Compton Run 21982 (standard): eDet Calib tests
232741 05/10/11 06:43 cdaq Compton End of Run 21981 (standard):
232740 05/10/11 06:37 cdaq Compton Run 21981 (standard): eDet Calib tests
232739 05/10/11 06:33 cdaq Compton End of Run 21980 (standard):
232738 05/10/11 06:13 cdaq Compton Run 21980 (standard): eDet Calib tests
232737 05/10/11 06:10 cdaq Compton End of Run 21979 (standard):
232736 05/10/11 05:59 cdaq Compton Run 21979 (standard): eDet Calib tests, det HV @ 400V
232735 05/10/11 05:51 narayan Compton: details for run # 21978
232734 05/10/11 05:40 Mitra ioc4 alarm
232733 05/10/11 05:23 cdaq Compton Run 21978 (standard): eDet Calibration input tests, det HV @ 400V
232732 05/10/11 04:08 Mitra HV Settings snapshot
232731 05/10/11 04:07 Mitra General Tools Snapshot
232730 05/10/11 03:18 Dutta Energy measurement fails
232729 05/10/11 00:54 Dutta QTOR cannot be recovered at this time
232728 05/10/11 00:16 cdaq Beam Time Accounting
232727 05/10/11 00:15 kamyers Shift Summary: Swing Shift Summary
232726 05/10/11 00:10 kamyers W plug image with target in
Monday
232725 05/09/11 23:38 kamyers QTOR tripped again, and again
232724 05/09/11 23:20 kamyers QTOR trip, recovered
232723 05/09/11 23:17 cdaq End of Run 12042:
232722 05/09/11 23:16 cdaq Run 12042 Pedestal Data
232721 05/09/11 23:09 kamyers TSO hang up, missed helicity gates
232720 05/09/11 23:09 cdaq Run 12042: Pedestal
232719 05/09/11 23:02 cdaq Run 12041: Pedestal
232718 05/09/11 23:01 kamyers w plug back out/steer into plug set up
232717 05/09/11 22:49 kamyers my mistake in mixing up the coordinate system
232716 05/09/11 22:45 hamlet Target: Move LH2 target out of the beam to home
232715 05/09/11 22:42 kamyers not sure where the scanner actually is
232714 05/09/11 22:38 cdaq End of Run 12040:
232713 05/09/11 22:37 kamyers W plug image from target out run - with figure
232712 05/09/11 22:37 kamyers W plug image from target out run
232711 05/09/11 22:25 kamyers run plan comment: max target out current is 75 uA
232710 05/09/11 22:18 cdaq Run 12040: W Plug map, Target LH2
232709 05/09/11 22:17 kamyers target BPM and scaler screen shots
232708 05/09/11 22:17 hamlet Target: Move Hydrogen target in the beam
232707 05/09/11 22:12 cdaq End of Run 12039:
232706 05/09/11 22:09 dunne Need to reduce currents for smaller raster size on dummy targets
232705 05/09/11 22:06 kamyers scanner moved to 0,0
232704 05/09/11 21:59 cdaq Run 12039: W Plug map, Target out, Attempt 2
232703 05/09/11 21:52 hamlet Target: Target GUI and strip charts screenshots for swing shift
232702 05/09/11 21:46 mack plugged octant 7 test plan for Tuesday morning
232701 05/09/11 21:42 cdaq End of Run 12038:
232700 05/09/11 21:36 cdaq Run 12038: W Plug map, Target out
232699 05/09/11 21:32 kamyers target BPM and scaler screen shot
232698 05/09/11 21:28 kamyers getting ready for W plug maps: fake mps, bkgd HV on
232697 05/09/11 21:15 rakithab/hos Analysis: Moller Polarization Results
232696 05/09/11 21:00 rakithab Moller Measurement done. Backing Out
232695 05/09/11 20:46 cdaq Moller Run 1225: IHWP=IN Production
232694 05/09/11 20:43 jhoskins IHWP = IN for this run.
232693 05/09/11 20:37 cdaq Moller Run 1224: IHWP=OUT Production
232692 05/09/11 20:30 kamyers FlipPCValues output
232691 05/09/11 20:30 cdaq Moller Run 1223: IHWP=IN Production
232690 05/09/11 20:21 cdaq Moller Run 1222: IHWP=OUT Production
232689 05/09/11 20:14 cdaq Moller Run 1221: IHWP=OUT Production
232688 05/09/11 20:08 cdaq Moller Run 1220: IHWP=OUT Production
232687 05/09/11 20:03 cdaq Moller Run 1219: IHWP=OUT Production
232686 05/09/11 19:58 rakithab BPM positions during Moller Production
232685 05/09/11 19:56 cdaq Moller Run 1217: IHWP=OUT Production
232684 05/09/11 19:54 cdaq Moller Run 1216: IHWP=OUT tune check
232683 05/09/11 19:51 cdaq Moller Run 1215: IHWP=IN Production - at x= +1 and y= +1
232682 05/09/11 19:05 hamlet Target: Move LH2 target out from the beam to the Home position
232681 05/09/11 18:54 kamyers switched back to accelerator mps
232680 05/09/11 18:49 rakithab Moller Initial Setup
232679 05/09/11 18:41 rakithab Injector parameter at the beginning of the Moller measurement
232678 05/09/11 18:30 kamyers MCC going to send tune beam
232677 05/09/11 18:28 cdaq End of Run 12037:
232676 05/09/11 18:07 kamyers Beam update
232675 05/09/11 18:07 mack test plan - high current FC2 calibration by the Unser
232674 05/09/11 18:01 jhlee modifiy plot_raster
232673 05/09/11 17:51 Pitt "Dump beam in tungsten plug" testplan
232672 05/09/11 17:29 rob touched templeton shielding; set up telescope as a possible trigger for raster map
232671 05/09/11 17:22 Nuruzzaman Analysis: Modified "qwanalysis" script.
232670 05/09/11 17:14 cdaq Run 12037: telescope test, waiting for beam
232669 05/09/11 17:02 rakithab Special Instructions to run plot_raster
232668 05/09/11 16:13 cdaq Beam Time Accounting
232667 05/09/11 16:09 gaskell Moller: beam-right hall probe moved to top
232666 05/09/11 15:57 Armstrong Shift Summary: Day Shift summary - May 9 2010
232665 05/09/11 15:20 Armstrong Shift checklist snapshots
232664 05/09/11 13:51 magee Target: Mid-day screenshots
232663 05/09/11 12:54 dalton Beam: Injector studies runs
232662 05/09/11 12:26 buddhini Started some injector analysis on cdaql3
232661 05/09/11 11:26 gaskell Compton: more shielding in front of Photon detector
232660 05/09/11 11:24 gaskell Compton: flipper repaired, re-installed
232659 05/09/11 11:06 rob lost hclog entry: Shift Summary: Swing 05/08/2011
232658 05/09/11 10:49 rob removed six dosimeters from cable trays
232657 05/09/11 10:34 Armstrong Target: Hall A target cooldown will start in about one hour
232656 05/09/11 10:19 Armstrong Hall C Curvey complete
232655 05/09/11 09:22 suhring Faraday Cup cross calibration
232654 05/09/11 09:16 Armstrong Survey started; need for access to Hall C?
232653 05/09/11 09:14 narayan Compton: eDet garaged, phDet HV off
232652 05/09/11 08:58 cdaq End of Run 12036:
232651 05/09/11 08:10 cdaq Beam Time Accounting
232650 05/09/11 07:57 Dutta Ramping QTOR to zero current
232649 05/09/11 07:55 cdaq Run 12036: Pedestal Run
232648 05/09/11 07:52 Dutta Shift Summary: Owl Shift summary 05/09/11
232647 05/09/11 07:50 Dutta Shift Summary: Owl Shift summary 05/09/11
232646 05/09/11 07:46 qwanalysis Analysis: Run 12035 - Plots and Summary Table for 100k Events.
232645 05/09/11 07:46 magee Target: Early morning screenshots
232644 05/09/11 07:45 cdaq End of Run 12035:
232643 05/09/11 07:45 cdaq Compton End of Run 21977 (standard):
232642 05/09/11 07:33 cdaq Compton Run 21977 (standard): I=170uA
232641 05/09/11 07:32 cdaq Run 12035: LH2 production at 170uA
232640 05/09/11 07:32 cdaq Compton End of Run 21976 (standard):
232639 05/09/11 07:32 cdaq End of Run 12034:
232638 05/09/11 07:05 Dutta Bellows temperature chart for owl shift
232637 05/09/11 06:39 qwanalysis Analysis: Run 12034 - Plots and Summary Table for 100k Events.
232636 05/09/11 06:12 narayan Compton: screenshot of the recent DAQ crash
232635 05/09/11 06:05 cdaq Run 12034: LH2 production at 170uA
232634 05/09/11 06:05 cdaq Compton Run 21976 (standard): I=170uA
232633 05/09/11 06:03 cdaq Compton End of Run 21975 (standard):
232632 05/09/11 05:59 cdaq End of Run 12033:
232631 05/09/11 05:12 qwanalysis Analysis: Run 12033 - Plots and Summary Table for 100k Events.
232630 05/09/11 05:05 cdaq Run 12033: LH2 production at 170uA
232629 05/09/11 04:58 cdaq Compton Run 21975 (standard): I=170uA
232628 05/09/11 04:57 cdaq Compton End of Run 21974 (standard):
232627 05/09/11 04:56 cdaq End of Run 12032:
232626 05/09/11 04:20 Korkmaz GT and HV plots
232625 05/09/11 04:00 qwanalysis Analysis: Run 12032 - Plots and Summary Table for 100k Events.
232624 05/09/11 03:59 cdaq Compton Run 21974 (standard): I=170uA
232623 05/09/11 03:53 Dutta Compton DAQ crashed
232622 05/09/11 03:52 qwanalysis Analysis: Run 12031 - Plots and Summary Table for 100k Events.
232621 05/09/11 03:48 cdaq Run 12032: LH2 production at 170uA
232620 05/09/11 03:45 cdaq End of Run 12031:
232619 05/09/11 02:42 cdaq Compton Run 21973 (standard): I=170uA
232618 05/09/11 02:42 cdaq Run 12031: LH2 production at 170uA
232617 05/09/11 02:41 cdaq Compton End of Run 21972 (standard):
232616 05/09/11 02:41 cdaq End of Run 12030:
232615 05/09/11 02:15 qwanalysis Analysis: Run 12030 - Plots and Summary Table for 100k Events.
232614 05/09/11 01:58 narayan Compton: run # 21957-21960 have all eDet planes at HV=400
232613 05/09/11 01:35 cdaq Compton Run 21972 (standard): I=170uA
232612 05/09/11 01:34 cdaq Run 12030: LH2 production at 170uA
232611 05/09/11 01:34 cdaq Compton End of Run 21971 (standard):
232610 05/09/11 01:33 cdaq End of Run 12029:
232609 05/09/11 00:54 cdaq Compton Run 21971 (standard): I=170uA
232608 05/09/11 00:50 qwanalysis Analysis: Run 12029 - Plots and Summary Table for 100k Events.
232607 05/09/11 00:36 cdaq Run 12029: LH2 production at 170uA
232606 05/09/11 00:35 cdaq Compton End of Run 21970 (standard):
232605 05/09/11 00:34 cdaq End of Run 12028:
232604 05/09/11 00:31 cdaq Compton Run 21970 (standard): I=170uA
232603 05/09/11 00:29 cdaq Run 12028: IHWP pulled out: transition run
232602 05/09/11 00:28 Dutta Output of FlipPCValues script when IWHP was pulled out
232601 05/09/11 00:23 cdaq Compton End of Run 21969 (standard):
232600 05/09/11 00:23 cdaq End of Run 12027:
232599 05/09/11 00:06 Korkmaz Target: Target GUI and strip charts screenshots at start of owl shift
232598 05/09/11 00:04 cdaq Beam Time Accounting
232597 05/09/11 00:01 hamlet Beam current, tungsten plug and bellows temperature during swing shift
232596 05/09/11 00:01 mack Failure of high current calibration of FC against the Unser
Sunday
232594 05/08/11 23:34 qwanalysis Analysis: Run 12027 - Plots and Summary Table for 100k Events.
232593 05/08/11 23:31 mack/jiawei late entry: notes from low current FC calibration
232592 05/08/11 23:22 cdaq Compton Run 21969 (standard): I=170uA
232591 05/08/11 23:22 cdaq Compton End of Run 21968 (standard):
232590 05/08/11 23:21 cdaq Run 12027: LH2 production at 170uA
232589 05/08/11 23:21 cdaq End of Run 12026:
232588 05/08/11 23:16 manos Started injector run 2410
232587 05/08/11 23:00 manos Swing shift snapshots
232586 05/08/11 22:57 manos QTor communication failure
232585 05/08/11 22:44 qwanalysis Analysis: Run 12026 - Plots and Summary Table for 100k Events.
232584 05/08/11 22:36 manos Valve closed again
232583 05/08/11 22:15 cdaq Run 12026: LH2 production at 170uA
232582 05/08/11 22:15 cdaq End of Run 12025:
232581 05/08/11 22:06 cdaq Compton Run 21968 (standard): I=170uA
232580 05/08/11 21:48 manos beam down for a while
232579 05/08/11 21:18 cdaq Run 12025: LH2 production at 170uA
232578 05/08/11 21:17 cdaq End of Run 12024:
232577 05/08/11 20:30 qwanalysis Analysis: Run 12024 - Plots and Summary Table for 100k Events.
232576 05/08/11 20:22 manos Requested 170uA
232575 05/08/11 20:18 cdaq Compton Run 21967 (standard): I=170uA
232574 05/08/11 20:17 cdaq Run 12024: LH2 production at 170uA
232573 05/08/11 20:17 cdaq Compton End of Run 21966 (standard):
232572 05/08/11 20:17 cdaq End of Run 12023:
232571 05/08/11 19:28 qwanalysis Analysis: Run 12023 - Plots and Summary Table for 100k Events.
232570 05/08/11 19:16 cdaq Compton Run 21966 (standard): I=165uA
232569 05/08/11 19:16 cdaq Run 12023: LH2 production at 165uA
232568 05/08/11 19:15 cdaq Compton End of Run 21965 (standard):
232567 05/08/11 19:15 cdaq End of Run 12022:
232566 05/08/11 18:52 manos Unstable beam
232565 05/08/11 18:29 qwanalysis Analysis: Run 12022 - Plots and Summary Table for 100k Events.
232564 05/08/11 18:15 dalton Compton: BPM calibration
232563 05/08/11 18:12 cdaq Compton Run 21965 (standard): I=165uA
232562 05/08/11 18:11 cdaq Run 12022: LH2 production at 165uA
232561 05/08/11 18:08 cdaq End of Run 12021:
232560 05/08/11 18:07 cdaq Compton End of Run 21964 (standard):
232559 05/08/11 17:58 rakithab BCM17 30 dB attenuator inserted
232558 05/08/11 17:55 cdaq Compton Run 21964 (standard): BPM calibration
232557 05/08/11 17:55 cdaq Run 12021: BPM calibration at 165uA
232556 05/08/11 17:54 Jiawei Was not able to do the high current calibration because of the faraday cup problem
232555 05/08/11 17:39 Jiawei run 12020 is a junk run
232554 05/08/11 17:38 rakithab Moller Run 1214 is junk
232553 05/08/11 17:38 cdaq End of Run 12020:
232552 05/08/11 17:33 cdaq Moller Run 1214: High current BCM calibration.
232551 05/08/11 17:30 cdaq Run 12020: High Current Calibration at 150 muA
232550 05/08/11 17:29 rakithab Moller Run 1213 is junk
232549 05/08/11 17:29 jiawei Just a test
232548 05/08/11 17:28 cdaq End of Run 12019:
232547 05/08/11 17:26 cdaq Moller Run 1213: High current BCM calibration.
232546 05/08/11 17:26 cdaq Run 12019: High Current Calibration at 150 muA
232545 05/08/11 17:20 hamlet Target: Move LH2 target in the beam
232544 05/08/11 17:16 mack bcm1,2 gains back to 2 for high current running (nuf said)
232543 05/08/11 17:15 cdaq Compton End of Run 21963 (standard):
232542 05/08/11 17:15 cdaq End of Run 12018:
232541 05/08/11 16:53 rakithab PITA and IA Scan Summary
232540 05/08/11 16:50 rajotte steady increase of X position difference since April 28th
232539 05/08/11 16:35 cdaq Compton Run 21963 (standard): I toggling 0.07-5uA, Y=0.74mm
232538 05/08/11 16:33 cdaq Compton End of Run 21962 (standard):
232537 05/08/11 16:30 rakithab Moller Run #1211 is junk
232536 05/08/11 16:28 cdaq Compton Run 21962 (standard): I=5uA, Y=0.74mm
232535 05/08/11 16:27 cdaq Moller Run 1212: Low current BCM calibration.
232534 05/08/11 16:24 cdaq Moller Run 1211: Low current BCM calibration.
232533 05/08/11 16:24 cdaq Run 12018: Low current FC calibration at 5 muA
232532 05/08/11 16:14 hamlet Target: Target GUI and strip charts screenshots at start of swing shift
232531 05/08/11 16:13 rakithab Correct Injector run number is 1208
232530 05/08/11 16:12 rakithab Correct injector run number is 2407
232529 05/08/11 16:10 Mitra Day Shift Summary
232528 05/08/11 16:08 hamlet Target: Move LH2 target out from beam to Home position
232527 05/08/11 16:07 cdaq Beam Time Accounting
232526 05/08/11 16:07 cdaq Compton End of Run 21961 (standard):
232525 05/08/11 16:05 rakithab The moller run 1210 is junk
232524 05/08/11 16:03 cdaq Compton Run 21961 (standard): junk
232523 05/08/11 16:02 cdaq End of Run 12017:
232522 05/08/11 16:01 cdaq Run 12017: test
232521 05/08/11 15:57 cdaq Moller Run 1210: Low current BCM calibration.
232520 05/08/11 15:44 Mitra Low Current FC Calibration
232519 05/08/11 15:39 cdaq Moller Run 1209: DAQ test
232518 05/08/11 15:37 mack bcm1,2 to gain setting number 5 (nuf said)
232517 05/08/11 15:37 magee BCM17 removed -re-booted Moller crate
232516 05/08/11 15:34 cdaq Compton End of Run 21960 (standard):
232515 05/08/11 15:34 cdaq End of Run 12016:
232514 05/08/11 15:27 cdaq Run 12016: LH2 production at 165uA
232513 05/08/11 15:25 cdaq End of Run 12015:
232512 05/08/11 15:24 rakithab Turned ON charge feedback and Beam Modulation at the end of the run 12015
232511 05/08/11 15:20 rakithab Parity Controls at the end of the IA and PITA scan
232510 05/08/11 15:14 jhlee one should select "analysis" on "location"
232509 05/08/11 15:08 Mitra HV settings snap shot
232508 05/08/11 14:58 jhlee data tracker is working fine
232507 05/08/11 14:56 Mitra General Tools screen shot
232506 05/08/11 14:47 rakithab Injector run 1208 started at 165uA for PITA Scan
232505 05/08/11 14:46 cdaq Run 12015: PITA Scan at 165uA
232504 05/08/11 14:45 cdaq End of Run 12014:
232503 05/08/11 14:41 cdaq Compton Run 21960 (standard): I=140uA, Y=0.74mm (PITA and IA scan underway)
232502 05/08/11 14:15 rakithab Switched Pockels Cell ON before the run 12014
232501 05/08/11 14:15 rakithab Started injector run 1207 for PITA scan at 140uA
232500 05/08/11 14:12 rakithab Parity Controls Screen at Hall C IA set to 33000
232499 05/08/11 14:10 cdaq Run 12014: PITA Scan at 140uA
232498 05/08/11 14:09 cdaq End of Run 12013:
232497 05/08/11 13:43 rakithab Injector run 2406 started for IA scan at 140uA
232496 05/08/11 13:35 cdaq Run 12013: IA Scan at 140uA
232495 05/08/11 13:33 cdaq End of Run 12012:
232494 05/08/11 13:33 rakithab Parity Controls Screen at Hall C IA set to 33000
232493 05/08/11 13:28 magee Target: lunchtime screenshots
232492 05/08/11 13:17 rakithab Parity Controls Screen at Hall C IA set to 3000
232491 05/08/11 13:15 rakithab Parity Controls Screen at Hall C IA set to 63000
232490 05/08/11 13:11 kamyers data tracker GUI messed up?
232489 05/08/11 13:03 rakithab Switched Pockels Cell OFF for the parity run 12012 and injector run 2405
232488 05/08/11 13:02 dalton Beam: High Current Injector BPM calibration: Injector run 2404
232487 05/08/11 12:59 rakithab Started injector run 2405 for IA scan at 165uA
232486 05/08/11 12:58 cdaq Compton Run 21959 (standard): I=165uA, Y=0.74mm (PITA and IA scan underway)
232485 05/08/11 12:53 cdaq Run 12012: IA Scan at 165uA
232484 05/08/11 11:53 Benesch Beam: no dispersion leakage seen in hall C - instrumental?
232483 05/08/11 11:50 dunne Started Polarized source injector pedestal scan
232482 05/08/11 10:50 cdaq Compton End of Run 21958 (standard):
232481 05/08/11 10:48 magee Qtor is back
232480 05/08/11 10:47 cdaq End of Run 12011:
232479 05/08/11 10:32 magee Qtor saga continues (stopped ramping at 6300A...)
232478 05/08/11 10:21 magee Qtor trip - reset power supply
232477 05/08/11 09:46 qwanalysis Analysis: Run 12011 - Plots and Summary Table for 100k Events.
232476 05/08/11 09:33 cdaq Run 12011: LH2 production at 165uA
232475 05/08/11 09:24 cdaq End of Run 12010:
232474 05/08/11 09:11 magee compton lock for run 21958 might be incorrect
232473 05/08/11 09:07 cdaq Compton Run 21958 (standard): I=165uA, Y=0.84mm
232472 05/08/11 09:07 cdaq Compton End of Run 21957 (standard):
232471 05/08/11 09:07 cdaq Run 12010: LH2 production at 165uA
232470 05/08/11 08:59 Mitra No beam
232469 05/08/11 08:55 cdaq End of Run 12009:
232468 05/08/11 08:53 magee Target: Early morning screenshots
232467 05/08/11 08:51 cdaq Compton Run 21957 (standard): I=165uA, Y=0.84mm
232466 05/08/11 08:39 Mitra IHWP --> IN
232465 05/08/11 08:19 cdaq Compton End of Run 21956 (standard):
232464 05/08/11 08:15 cdaq Run 12009: LH2 production at 165uA
232463 05/08/11 08:14 cdaq End of Run 12008:
232462 05/08/11 08:03 cdaq Beam Time Accounting
232461 05/08/11 08:01 Shift Summary:
232460 05/08/11 07:21 qwanalysis Analysis: Run 12008 - Plots and Summary Table for 100k Events.
232459 05/08/11 07:14 Dutta Compton: run 21955 has eDet HV=400V for all planes
232458 05/08/11 07:09 cdaq Compton Run 21956 (standard): I=165uA, Y=0.79mm
232457 05/08/11 07:08 cdaq Compton End of Run 21955 (standard):
232456 05/08/11 07:08 cdaq Run 12008: LH2 production at 165uA
232455 05/08/11 07:07 cdaq End of Run 12007:
232454 05/08/11 06:22 qwanalysis Analysis: Run 12007 - Plots and Summary Table for 100k Events.
232453 05/08/11 06:12 cdaq Compton Run 21955 (standard): I=165uA, Y=0.79mm
232452 05/08/11 06:11 cdaq Compton End of Run 21954 (standard):
232451 05/08/11 06:08 cdaq Run 12007: LH2 production at 165uA
232450 05/08/11 06:08 cdaq Compton Run 21954 (standard): I=165uA, Y=0.84mm
232449 05/08/11 06:07 cdaq Compton End of Run 21953 (standard):
232448 05/08/11 06:07 cdaq End of Run 12006:
232447 05/08/11 05:27 Korkmaz GT and HV plots
232446 05/08/11 05:14 qwanalysis Analysis: Run 12006 - Plots and Summary Table for 100k Events.
232445 05/08/11 05:03 cdaq Compton Run 21953 (standard): I=165uA, Y=0.84mm, eDet HV = 400
232444 05/08/11 04:59 cdaq Compton End of Run 21952 (standard):
232443 05/08/11 04:59 cdaq Run 12006: LH2 production at 165uA
232442 05/08/11 04:59 cdaq End of Run 12005:
232441 05/08/11 04:13 qwanalysis Analysis: Run 12005 - Plots and Summary Table for 100k Events.
232440 05/08/11 04:00 cdaq Compton Run 21952 (standard): I=165uA, Y=0.84mm
232439 05/08/11 03:59 cdaq Compton End of Run 21951 (standard):
232438 05/08/11 03:58 cdaq Run 12005: LH2 production at 165uA
232437 05/08/11 03:58 cdaq End of Run 12004:
232436 05/08/11 03:40 qwanalysis Analysis: Run 12004 - Plots and Summary Table for 100k Events.
232435 05/08/11 02:57 cdaq Compton Run 21951 (standard): I=165uA, Y changed to 0.84mm from 0.89 for this run
232434 05/08/11 02:55 cdaq Run 12004: LH2 production at 165uA
232433 05/08/11 02:54 cdaq Compton End of Run 21950 (standard):
232432 05/08/11 02:54 cdaq End of Run 12003:
232431 05/08/11 02:07 qwanalysis Analysis: Run 12003 - Plots and Summary Table for 100k Events.
232430 05/08/11 01:55 cdaq Compton Run 21950 (standard): I=165uA, Y=0.84mm
232429 05/08/11 01:50 cdaq Compton End of Run 21949 (standard):
232428 05/08/11 01:50 cdaq Run 12003: LH2 production at 165uA
232427 05/08/11 01:49 cdaq End of Run 12002:
232426 05/08/11 01:04 qwanalysis Analysis: Run 12002 - Plots and Summary Table for 100k Events.
232425 05/08/11 00:49 cdaq Compton Run 21949 (standard): I=165uA, Y=0.89mm
232424 05/08/11 00:49 cdaq Run 12002: LH2 production at 165uA
232423 05/08/11 00:49 cdaq Compton End of Run 21948 (standard):
232422 05/08/11 00:49 cdaq End of Run 12001:
232421 05/08/11 00:13 narayan Compton: plane 2, strip 10 masked for this run
232420 05/08/11 00:06 cdaq Beam Time Accounting
232419 05/08/11 00:05 manos Shift Summary: Swing 05/07/2011
232418 05/08/11 00:04 qwanalysis Analysis: Run 12001 - Plots and Summary Table for 100k Events.
232417 05/08/11 00:03 Korkmaz Target: Target GUI and strip charts screenshots at start of owl shift
Saturday
232416 05/07/11 23:55 hamlet Beam current, tungsten plug and bellows temperature during swing shift
232415 05/07/11 23:49 cdaq Compton Run 21948 (standard): I=165uA, Y=0.89mm
232414 05/07/11 23:48 cdaq Run 12001: LH2 production at 165uA
232413 05/07/11 23:48 cdaq End of Run 12000:
232412 05/07/11 23:42 cdaq Compton End of Run 21947 (standard):
232411 05/07/11 23:37 manos IHWP -> OUT
232410 05/07/11 23:35 cdaq Run 12000: LH2 production at 165uA, transition run after HWP change
232409 05/07/11 23:34 cdaq End of Run 11999:
232408 05/07/11 22:55 manos Plots for previous entry
232407 05/07/11 22:50 manos Huge X-posiition difference at target
232406 05/07/11 22:36 qwanalysis Analysis: Run 11999 - Plots and Summary Table for 100k Events.
232405 05/07/11 22:34 cdaq Compton Run 21947 (standard): I=165uA, Y=0.84mm
232404 05/07/11 22:24 cdaq Run 11999: LH2 production at 165uA
232403 05/07/11 22:09 cdaq Compton End of Run 21946 (standard):
232402 05/07/11 22:07 cdaq End of Run 11998:
232401 05/07/11 21:51 manos Swing shift screenshots
232400 05/07/11 21:41 manos Started injector run 2402
232399 05/07/11 21:21 qwanalysis Analysis: Run 11998 - Plots and Summary Table for 100k Events.
232398 05/07/11 21:10 cdaq Compton Run 21946 (standard): I=165uA, Y=0.84mm
232397 05/07/11 21:09 cdaq Compton End of Run 21945 (standard):
232396 05/07/11 21:08 cdaq Run 11998: LH2 production at 165uA
232395 05/07/11 21:08 cdaq End of Run 11997:
232394 05/07/11 20:19 qwanalysis Analysis: Run 11997 - Plots and Summary Table for 100k Events.
232393 05/07/11 20:08 cdaq Compton Run 21945 (standard): I=165uA
232392 05/07/11 20:08 cdaq Compton End of Run 21944 (standard):
232391 05/07/11 20:07 Jiawei position sensitivities from recent runs with different target y position.
232390 05/07/11 20:07 cdaq Run 11997: LH2 production at 165uA
232389 05/07/11 20:06 cdaq End of Run 11996:
232388 05/07/11 19:29 qwanalysis Analysis: Run 11996 - Plots and Summary Table for 100k Events.
232387 05/07/11 19:19 manos Compton: Beam profile scan : moved orbit lock to 0.74mm
232386 05/07/11 19:18 jhlee a minor change in the runend.tcl script
232385 05/07/11 19:12 cdaq Compton Run 21944 (standard): I=165uA
232384 05/07/11 19:08 manos Scanner vertical scan ended, back to production
232383 05/07/11 19:07 hamlet Target: Change target. Put LH2 target in the Beam. Raster now back to 4.0 x 4.0
232382 05/07/11 19:07 cdaq Run 11996: LH2 production at 165uA
232381 05/07/11 19:03 cdaq Compton End of Run 21943 (standard):
232380 05/07/11 19:02 cdaq End of Run 11995:
232379 05/07/11 18:55 qwanalysis Analysis: Run 11995 - Plots and Summary Table for 100k Events.
232378 05/07/11 18:53 hamlet Probably QWT_solidB is a right thermocontrol for 1% Al
232377 05/07/11 18:35 qwanalysis Analysis: Run 11994 - Plots and Summary Table for 100k Events.
232376 05/07/11 18:31 cdaq Run 11995: S-scan vertical, I=65uA, raster 3.5x3.5, 9054A QTor current
232375 05/07/11 18:28 cdaq End of Run 11994:
232374 05/07/11 18:13 cdaq Compton Run 21943 (standard): no flipper
232373 05/07/11 18:05 manos Scanner vertical scan
232372 05/07/11 18:03 narayan Compton: HV for run 21942 was 400V for all eDet planes
232371 05/07/11 18:01 hamlet Target: Change target. Take out LH2, Move in US 1% Al target.
232370 05/07/11 18:00 cdaq Run 11994: S-scan vertical, I=65uA, raster 3.5x3.5, nominal QTor current
232369 05/07/11 17:50 cdaq End of Run 11993:
232368 05/07/11 17:50 cdaq Compton End of Run 21942 (standard):
232367 05/07/11 17:32 manos Very small Y-sensitivity, very large X-position differences at target
232366 05/07/11 17:07 qwanalysis Analysis: Run 11993 - Plots and Summary Table for 100k Events.
232365 05/07/11 16:58 hamlet Target: Target GUI and strip charts screenshots at start of swing shift
232364 05/07/11 16:56 cdaq Compton Run 21942 (standard): no flipper
232363 05/07/11 16:56 cdaq Compton End of Run 21941 (standard):
232362 05/07/11 16:55 cdaq Run 11993: LH2 production at 165uA
232361 05/07/11 16:54 cdaq End of Run 11992:
232360 05/07/11 16:17 narayan Compton: HV for run 21941 was 400V for all eDet planes
232359 05/07/11 16:09 qwanalysis Analysis: Run 11992 - Plots and Summary Table for 100k Events.
232358 05/07/11 16:02 cdaq Beam Time Accounting
232357 05/07/11 15:58 cdaq Compton Run 21941 (standard): no flipper
232356 05/07/11 15:57 vanoers Shift Summary: Day Shift summary
232355 05/07/11 15:53 kamyers Beam: also saw halo rate increase with raster size during tracking running thursday
232354 05/07/11 15:51 cdaq Run 11992: LH2 production at 165uA, raster : 4.0.by 4.o and IHWP : IN
232353 05/07/11 15:49 vanoers IHWP IN
232352 05/07/11 15:48 cdaq Compton End of Run 21940 (standard):
232351 05/07/11 15:45 cdaq End of Run 11991:
232350 05/07/11 15:02 qwanalysis Analysis: Run 11991 - Plots and Summary Table for 100k Events.
232349 05/07/11 15:00 benesch Beam: halo rates up an eighth at 5x5 vs 4x4
232348 05/07/11 14:47 cdaq Run 11991: LH2 production at 165uA, raster : 5.0 by 5.0
232347 05/07/11 14:47 cdaq Compton Run 21940 (standard): no flipper
232346 05/07/11 14:45 cdaq End of Run 11990:
232345 05/07/11 14:45 cdaq Compton End of Run 21939 (standard):
232344 05/07/11 14:18 vanoers GT and HV plots
232343 05/07/11 13:54 vanoers Beam: Run 11989 had very little beam delivered: cause of the low counts
232342 05/07/11 13:52 Benesch Beam: halo rates went up 5% when raster changed from 4x4 to 4.5x4.5
232341 05/07/11 13:46 qwanalysis Analysis: Run 11989 - Plots and Summary Table for 100k Events.
232340 05/07/11 13:43 cdaq Run 11990: LH2 production at 165uA, raster : 4.5 by 4.5
232339 05/07/11 13:43 cdaq End of Run 11989:
232338 05/07/11 13:33 cdaq Compton Run 21939 (standard): no flipper
232337 05/07/11 13:29 cdaq Compton End of Run 21938 (standard):
232336 05/07/11 13:28 vanoers Beam: LH2 production run with raster size 4.5 by 4.5
232335 05/07/11 13:25 cdaq Run 11989: LH2 production at 165uA, raster : 4.5 by 4.5
232334 05/07/11 13:21 cdaq End of Run 11988:
232333 05/07/11 12:51 cdaq Compton Run 21938 (standard): no flipper
232332 05/07/11 12:46 target screens -- showing some recent history of QWPower and QW4K
232331 05/07/11 12:40 qwanalysis Analysis: Run 11988 - Plots and Summary Table for 100k Events.
232330 05/07/11 12:29 Korkmaz Target: target issues in the last 45 minutes
232329 05/07/11 12:25 cdaq Compton End of Run 21937 (standard):
232328 05/07/11 12:20 vanoers Beam:
232327 05/07/11 12:17 cdaq Run 11988: LH2 production at 165uA
232326 05/07/11 12:16 cdaq End of Run 11987:
232325 05/07/11 12:15 qwanalysis Analysis: Run 11987 - Plots and Summary Table for 100k Events.
232324 05/07/11 11:19 vanoers Beam:
232323 05/07/11 11:15 cdaq Compton Run 21937 (standard): no flipper
232322 05/07/11 11:15 cdaq Run 11987: LH2 production at 165uA
232321 05/07/11 10:50 cdaq End of Run 11986:
232320 05/07/11 10:49 cdaq Compton End of Run 21936 (standard):
232319 05/07/11 10:23 vanoers Beam Trips
232318 05/07/11 09:57 qwanalysis Analysis: Run 11986 - Plots and Summary Table for 100k Events.
232317 05/07/11 09:43 cdaq Compton Run 21936 (standard): no flipper
232316 05/07/11 09:42 cdaq Compton End of Run 21935 (standard):
232315 05/07/11 09:42 cdaq Run 11986: LH2 production at 165uA
232314 05/07/11 09:40 cdaq End of Run 11985:
232313 05/07/11 08:52 qwanalysis Analysis: Run 11985 - Plots and Summary Table for 100k Events.
232312 05/07/11 08:40 cdaq Compton Run 21935 (standard): no flipper
232311 05/07/11 08:40 cdaq Compton End of Run 21934 (standard):
232310 05/07/11 08:38 cdaq Run 11985: LH2 production at 165uA
232309 05/07/11 08:37 cdaq End of Run 11984:
232308 05/07/11 08:12 Dutta EDET position is blank on the Hall-C status screen
232307 05/07/11 08:02 cdaq Beam Time Accounting
232306 05/07/11 08:01 Dutta Shift Summary: Owl Shift summary 05/07/11
232305 05/07/11 07:52 qwanalysis Analysis: Run 11984 - Plots and Summary Table for 100k Events.
232304 05/07/11 07:45 L.Lee Target: Target GUI and strip charts screenshots towards end of owl shift
232303 05/07/11 07:36 cdaq Compton Run 21934 (standard): no flipper
232302 05/07/11 07:35 cdaq Run 11984: LH2 production at 165uA
232301 05/07/11 07:35 cdaq Compton End of Run 21933 (standard):
232300 05/07/11 07:35 cdaq End of Run 11983:
232299 05/07/11 06:47 qwanalysis Analysis: Run 11983 - Plots and Summary Table for 100k Events.
232298 05/07/11 06:32 cdaq Compton Run 21933 (standard): no flipper
232297 05/07/11 06:32 cdaq Run 11983: LH2 production at 165uA
232296 05/07/11 06:32 cdaq Compton End of Run 21932 (standard):
232295 05/07/11 06:32 cdaq End of Run 11982:
232294 05/07/11 05:43 qwanalysis Analysis: Run 11982 - Plots and Summary Table for 100k Events.
232293 05/07/11 05:22 cdaq Run 11982: LH2 production at 165uA
232292 05/07/11 05:22 cdaq Compton Run 21932 (standard): no flipper
232291 05/07/11 05:21 cdaq Compton End of Run 21931 (standard):
232290 05/07/11 05:21 cdaq End of Run 11981:
232289 05/07/11 04:43 Dutta late entry: IHWP taken OUT
232288 05/07/11 04:40 qwanalysis Analysis: Run 11981 - Plots and Summary Table for 100k Events.
232287 05/07/11 04:21 cdaq Run 11981: LH2 production at 165uA
232286 05/07/11 04:18 cdaq Compton Run 21931 (standard): no flipper
232285 05/07/11 04:17 cdaq End of Run 11980:
232284 05/07/11 04:11 cdaq Run 11980: LH2 production at 165uA
232283 05/07/11 04:10 Dutta Ouput of FlipPCValues Script
232282 05/07/11 04:09 cdaq Compton End of Run 21930 (standard):
232281 05/07/11 04:08 cdaq Compton Run 21930 (standard): no flipper
232280 05/07/11 04:07 cdaq End of Run 11979:
232279 05/07/11 04:06 cdaq Compton End of Run 21929 (standard):
232278 05/07/11 03:35 cdaq Compton Run 21929 (standard): no flipper
232277 05/07/11 03:26 qwanalysis Analysis: Run 11979 - Plots and Summary Table for 100k Events.
232276 05/07/11 03:11 L.Lee Target: Target GUI and strip charts screenshots for owl shift
232275 05/07/11 03:07 cdaq Run 11979: LH2 production at 165uA
232274 05/07/11 03:06 L.Lee Target: Move target in vertical direction back to nominal position
232273 05/07/11 03:01 cdaq Compton End of Run 21928 (standard):
232272 05/07/11 03:01 cdaq End of Run 11978:
232271 05/07/11 02:35 qwanalysis Analysis: Run 11978 - Plots and Summary Table for 100k Events.
232270 05/07/11 02:06 Dutta New wrinkle in the QTOR trip saga
232269 05/07/11 02:03 cdaq Compton Run 21928 (standard): no flipper
232268 05/07/11 02:03 cdaq Run 11978: LH2 production at 170 uA, target moved by -1.0 mm
232267 05/07/11 01:58 cdaq Compton End of Run 21927 (standard):
232266 05/07/11 01:55 jhlee reboot vmec18 and vmec19
232265 05/07/11 01:12 Jiawei Run 11976 and 11977 target position -0.5mm or -1mm?
232264 05/07/11 00:51 cdaq End of Run 11977:
232263 05/07/11 00:50 cdaq Run 11977: LH2 production at 170 uA, target moved by -0.5 mm
232262 05/07/11 00:48 jhlee fixed runend script, should wait one hour to see if it works or not.
232261 05/07/11 00:39 Dutta QTOR tripped
232260 05/07/11 00:34 cdaq Compton Run 21927 (standard): no flipper
232259 05/07/11 00:34 cdaq End of Run 11976:
232258 05/07/11 00:33 cdaq Run 11976: LH2 production at 170 uA, target moved by -0.5 mm
232257 05/07/11 00:28 L.Lee Target: Move target in vertical direction down by another 0.5 mm, now -1.0 mm relative to nominal position
232256 05/07/11 00:24 cdaq Compton End of Run 21926 (standard):
232255 05/07/11 00:23 cdaq End of Run 11975:
232254 05/07/11 00:02 cdaq Beam Time Accounting
Friday
232253 05/06/11 23:56 Ramesh Shift Summary
232252 05/06/11 23:45 qwanalysis Analysis: Run 11975 - Plots and Summary Table for 100k Events.
232251 05/06/11 23:39 Ramesh snapshot for checklist
232250 05/06/11 23:25 hamlet Beam, bellows and tungsten plug temperature during swing shift
232249 05/06/11 23:23 cdaq Run 11975: LH2 production at 170 uA, target moved by -0.5 mm
232248 05/06/11 23:22 Ramesh no end_of_run screen this shift so far
232247 05/06/11 23:20 hamlet Target: Move target in vertical direction down by 0.5 mm relative to nominal position
232246 05/06/11 23:18 cdaq Compton Run 21926 (standard): no flipper
232245 05/06/11 23:16 cdaq Compton End of Run 21925 (standard):
232244 05/06/11 23:15 cdaq End of Run 11974:
232243 05/06/11 22:43 Ramesh HV gui problem earlier in the Swing was due to hv_gui link problem
232242 05/06/11 22:36 qwanalysis Analysis: Run 11974 - Plots and Summary Table for 100k Events.
232241 05/06/11 22:16 cdaq Run 11974: LH2 production at 170 uA, target UP by +1 mm
232240 05/06/11 22:15 cdaq Compton Run 21925 (standard): electon detector moved in
232239 05/06/11 22:15 hamlet Target: Move target in vertical direction additional +0.5 mm, in total target moved in vertical direction by +1.0mm
232238 05/06/11 22:13 dalton Compton: Electron detector moved in
232237 05/06/11 22:08 cdaq Compton End of Run 21924 (standard):
232236 05/06/11 22:01 Ramesh Scanner HV and it's controller power off
232235 05/06/11 21:56 Ramesh Scanner Vertical scan finished
232234 05/06/11 21:53 dalton Compton: New beam position, y=0.79 mm
232233 05/06/11 21:50 dalton Compton: Flipper died
232232 05/06/11 21:46 qwanalysis Analysis: Run 11973 - Plots and Summary Table for 100k Events.
232231 05/06/11 21:26 Ramesh Scanner Vert scan run 11973
232230 05/06/11 21:15 hamlet Target: Move target in vertical direction by +0.5mm
232229 05/06/11 21:14 cdaq Run 11973: LH2 production at 170 uA, target UP by 0.5 mm, scanner Vert motion also
232228 05/06/11 21:09 cdaq End of Run 11972:
232227 05/06/11 21:05 cdaq Compton Run 21924 (standard): ebeam at Y=0.79 mm
232226 05/06/11 21:04 cdaq Compton End of Run 21923 (standard):
232225 05/06/11 20:36 qwanalysis Analysis: Run 11972 - Plots and Summary Table for 100k Events.
232224 05/06/11 20:25 Ramesh Run_end comment pink_screen missing
232223 05/06/11 20:23 cdaq Run 11972: LH2 production at 170 uA
232222 05/06/11 20:17 qwanalysis Analysis: Run 11971 - Plots and Summary Table for 100k Events.
232221 05/06/11 20:16 cdaq End of Run 11971:
232220 05/06/11 19:59 cdaq Compton Run 21923 (standard): Beam profile scan
232219 05/06/11 19:59 hamlet Target: Target GUI and strip charts screenshots at start of data taking during swing shift
232218 05/06/11 19:56 cdaq Run 11971: LH2 production at 170 uA
232217 05/06/11 19:55 cdaq End of Run 11970:
232216 05/06/11 19:41 qwanalysis Analysis: Run 11970 - Plots and Summary Table for 100k Events.
232215 05/06/11 19:27 rakithab turned on charge feedback and beam modulation
232214 05/06/11 19:27 cdaq Run 11970: LH2 beam back test run
232213 05/06/11 19:23 Ramesh HV gui working now
232212 05/06/11 19:16 hamlet Target: Move Hydrogen target on the beam
232211 05/06/11 18:49 Ramesh HV GUI won't respond, hard rebooting g0ioc2
232210 05/06/11 18:18 Ramesh Controlled access finished, restoring beam
232209 05/06/11 17:52 rakithab Re:Moller Systematic Study Summary
232208 05/06/11 17:45 rakithab Analysis: Moller Systematic Study Summary
232207 05/06/11 17:41 magee moller high voltage OFF
232206 05/06/11 17:41 Ramesh Escorted access to remove Compton laser obstruction
232205 05/06/11 17:41 rob killed rogue speech robot
232204 05/06/11 17:36 team moller Moller studies concluded for today.
232203 05/06/11 17:20 cdaq Moller Run 1208: leakage check - hall A with 120 uA.
232202 05/06/11 17:19 magee Tune plot of x=y=+1
232201 05/06/11 17:17 cdaq Moller Run 1207: tune check
232200 05/06/11 17:09 cdaq Moller Run 1206: IHWP=IN Production - at x= +1 and y= +1
232199 05/06/11 16:59 cdaq Moller Run 1205: IHWP=IN Production - at x= +1 and y= +1
232198 05/06/11 16:55 magee Speakers erroneously saying "beam is off" - speakers off
232197 05/06/11 16:54 cdaq Moller Run 1204: IHWP=IN Production - at x= +1 and y= +1
232196 05/06/11 16:43 cdaq Moller Run 1203: IHWP=IN Production - at x= +1 and y= +1
232195 05/06/11 16:41 cdaq Moller Run 1202: IHWP=IN Production - at x= +1 and y= +1
232194 05/06/11 16:27 cdaq End of Run 11969:
232193 05/06/11 16:23 cdaq Run 11969: DAQ test after TS0 crash
232192 05/06/11 16:11 cdaq Moller Run 1201: IHWP=IN Production - at x=- 1 and y= -1
232191 05/06/11 16:05 cdaq Moller Run 1200: IHWP=IN Production - at x=- 1 and y= -1
232190 05/06/11 16:04 cdaq Beam Time Accounting
232189 05/06/11 16:00 cdaq Moller Run 1199: IHWP=IN Production - at x=- 1 and y= -1
232188 05/06/11 15:59 magee Moller: tune - x=-1 y=-1
232187 05/06/11 15:55 cdaq Moller Run 1198: tune plot
232186 05/06/11 15:51 Solvignon Moller tune check at x=+0.5, y=0
232185 05/06/11 15:48 cdaq Moller Run 1197: tune check at x=+0.5, y=0
232184 05/06/11 15:41 cdaq Moller Run 1196: IHWP=IN Production - at x=+0.5, y=0
232183 05/06/11 15:38 cdaq Moller Run 1195: IHWP=IN Production - at x=+0.5, y=0
232182 05/06/11 15:33 vanoers Day shift: Moller runs
232181 05/06/11 15:30 cdaq Moller Run 1194: IHWP=IN Production - at x=+0.5, y=0
232180 05/06/11 15:25 Solvignon Moller: BPM screen at x=+0.5, y=0
232179 05/06/11 15:24 cdaq Moller Run 1193: IHWP=IN Production - at x=+0.5, y=0
232178 05/06/11 15:11 cdaq Moller Run 1192: IHWP=IN Production - large negative y: y=-2.0
232177 05/06/11 15:05 cdaq Moller Run 1191: IHWP=IN Production - large negative y: y=-2.0
232176 05/06/11 15:01 Solvignon Moller tune check at y=-2
232175 05/06/11 14:59 cdaq Moller Run 1190: IHWP=IN Production - large negative y: y=-2.0
232174 05/06/11 14:57 cdaq Moller Run 1189: tune check - large negative y: y=-2.0
232173 05/06/11 14:56 Solvignon Moller: BPM screen at y=-2
232172 05/06/11 14:55 Solvignon Moller: tune check at y=-1
232171 05/06/11 14:51 cdaq Moller Run 1188: tune check- large negative y: y=-1.0
232170 05/06/11 14:47 cdaq Moller Run 1187: IHWP=IN Production - large negative y: y=-1.0
232169 05/06/11 14:43 Armstrong Target IOC hangs; rebooted
232168 05/06/11 14:41 cdaq Moller Run 1186: IHWP=IN Production - large negative y: y=-1.0
232167 05/06/11 14:39 Solvignon Moller IOC rebooted
232166 05/06/11 14:22 Solvignon Moller: BPM screen at y=-1
232165 05/06/11 14:21 cdaq Moller Run 1185: IHWP=IN Production - large negative y: y=-1.0
232164 05/06/11 14:17 Solvignon Moller: BPM screen at x=0, y=1
232163 05/06/11 14:09 cdaq Moller Run 1184: IHWP=IN Production - large positive y: y=+1.0
232162 05/06/11 14:08 magee Moller: injector parameters - laser phase
232161 05/06/11 14:03 cdaq Moller Run 1183: IHWP=IN Production - large positive y: y=+1.0
232160 05/06/11 14:02 magee Moller: beam injector parameters half-way through
232159 05/06/11 14:02 cdaq Moller Run 1182: IHWP=IN Production - large positive y: y=+1.0
232158 05/06/11 13:54 cdaq Moller Run 1181: IHWP=IN Production - large positive y: y=+1.0
232157 05/06/11 13:53 Solvignon Moller tune check at y=+1
232156 05/06/11 13:48 cdaq Moller Run 1180: Tune check- large positive y: y=+1.0
232155 05/06/11 13:48 Solvignon Moller tune check at y=+2, x=0
232154 05/06/11 13:42 cdaq Moller Run 1179: tune check- large positive y: y=+2.0
232153 05/06/11 13:34 cdaq Moller Run 1178: IHWP=IN Production - large positive y: y=+2.0
232152 05/06/11 13:26 cdaq Moller Run 1177: IHWP=IN Production - large positive y: y=+2.0
232151 05/06/11 13:20 Solvignon Moller: BPM screen at x=0, y=+2.0
232150 05/06/11 13:19 cdaq Moller Run 1176: IHWP=IN Production - large positive y: y=+2.0
232149 05/06/11 13:07 cdaq Moller Run 1175: IHWP=IN Production - ideal position: x= 0, y=0
232148 05/06/11 13:02 cdaq Moller Run 1174: IHWP=IN Production - ideal position: x= 0, y=0
232147 05/06/11 12:55 cdaq Moller Run 1172: IHWP=IN Production - ideal position: x= 0, y=0
232146 05/06/11 12:54 Solvignon Moller tune check back at x=0, y=0
232145 05/06/11 12:47 cdaq Moller Run 1171: IHWP=IN Production - ideal position: x= 0, y=0
232144 05/06/11 12:44 Solvignon Moller: BPM screen, back to x=0, y=0
232143 05/06/11 12:43 cdaq Moller Run 1170: Tune check (back at x=0, y=0)
232142 05/06/11 12:41 Solvignon Moller Tune check after data taking at x=+2.0
232141 05/06/11 12:35 cdaq Moller Run 1169: tune check
232140 05/06/11 12:32 Armstrong Target Screens - midshift
232139 05/06/11 12:27 cdaq Moller Run 1168: IHWP=IN Production - large positive x: x= +2.0, y=0
232138 05/06/11 12:21 cdaq Moller Run 1167: IHWP=IN Production - large positive x: x= +2.0, y=0
232137 05/06/11 12:16 Solvignon Moller: BPM screen for x=+2.0, y=0
232136 05/06/11 12:14 cdaq Moller Run 1166: IHWP=IN Production - large positive x: x= +2.0, y=0
232135 05/06/11 12:11 Solvignon Moller Tune check after data taking at x=+0.075
232134 05/06/11 12:04 cdaq Moller Run 1165: tune check
232133 05/06/11 11:59 cdaq Moller Run 1163: IHWP=IN Production - large positive x: x= +0.75, y=0
232132 05/06/11 11:57 Solvignon Moller Tune check after data taking at x=-0.075
232131 05/06/11 11:53 cdaq Moller Run 1162: IHWP=IN Production - large positive x: x= +0.75, y=0
232130 05/06/11 11:52 magee Moller: BPM plots for x=0.75mm (- and +)
232129 05/06/11 11:47 cdaq Moller Run 1161: IHWP=IN Production - large positive x: x= +0.75, y=0
232128 05/06/11 11:40 cdaq Moller Run 1160: IHWP=IN Production - large positive x: x= +0.75, y=0
232127 05/06/11 11:30 cdaq Moller Run 1159: TUNE RUN
232126 05/06/11 11:23 cdaq Moller Run 1158: IHWP=IN Production - large negative x: x= -0.75, y=0
232125 05/06/11 11:13 cdaq Moller Run 1157: IHWP=IN Production - large negative x: x= -0.75, y=0
232124 05/06/11 11:08 cdaq Moller Run 1156: IHWP=IN Production - large negative x: x= -0.75, y=0
232123 05/06/11 11:05 Solvignon Moller: BPM screen for x=-2, y=0
232122 05/06/11 11:02 Solvignon Moller Tune check at x=-2, y=0
232121 05/06/11 11:00 cdaq Moller Run No msql server: tune check
232120 05/06/11 10:58 cdaq Moller Run 1154: Moller tune check
232119 05/06/11 10:52 cdaq Moller Run 1153: IHWP=IN Production - large negative x: x=-2, y=0
232118 05/06/11 10:46 cdaq Moller Run 1152: IHWP=IN Production - large negative x: x=-2, y=0
232117 05/06/11 10:41 cdaq Moller Run 1151: IHWP=IN Production - large negative x: x=-2, y=0
232116 05/06/11 10:40 cdaq Moller Run 1150: IHWP=IN Production - large negative x: x=-2, y=0
232115 05/06/11 10:31 brads re: slow cdaql6
232114 05/06/11 10:31 Solvignon Moller tune check after measurement at "ideal beam position"
232113 05/06/11 10:31 jhoskins Beam Modulation Driver File Updated
232112 05/06/11 10:26 cdaq Moller Run 1149: Moller tune check - Ideal position: x=0, y=0
232111 05/06/11 10:26 pking The MySQL server is running "standard" tasks; however X is using a large number of resources.
232110 05/06/11 10:19 cdaq Moller Run 1148: IHWP=IN Production - Ideal position: x=0, y=0
232109 05/06/11 10:18 jhlee closes 5 General_Tools on cdaql6
232108 05/06/11 10:16 cdaq Moller Run 1147: IHWP=IN Production - Ideal position: x=0, y=0
232107 05/06/11 10:10 cdaq Moller Run 1146: IHWP=IN Production - Ideal position: x=0, y=0
232106 05/06/11 10:08 Solvignon Moller tune after cycling the quad and at "ideal beam position"
232105 05/06/11 10:07 magee cdaql6 painfully slow
232104 05/06/11 10:07 benesch halo rates: orbit around fast raster
232103 05/06/11 10:05 cdaq Moller Run 1145: IHWP=IN Production - Ideal position: x=0, y=0
232102 05/06/11 10:01 cdaq Moller Run 1144: IHWP=IN Production - Ideal position: x=0, y=0
232101 05/06/11 09:56 Solvignon Moller tune: BPM position
232100 05/06/11 09:55 cdaq Moller Run 1143: Moller tune after cycling the quads
232099 05/06/11 09:34 cdaq Moller Run 1142: Moller tune check
232098 05/06/11 09:27 Solvignon Moller: BPM position
232097 05/06/11 09:11 jhlee cdaql5 disk isn't full, and it was full.
232096 05/06/11 08:34 magee Moller set-up
232095 05/06/11 08:32 Armstrong Target moved to out-of-beam; QTor ramped to zero
232094 05/06/11 08:30 magee Moller: beam injector parameters
232093 05/06/11 08:29 magee Ramping qtor down
232092 05/06/11 08:26 cdaq End of Run 11968:
232091 05/06/11 08:25 Armstrong Setting up for Moller
232090 05/06/11 08:25 cdaq Run 11968: DAQ test
232089 05/06/11 08:23 cdaq Compton End of Run 21922 (standard):
232088 05/06/11 08:22 cdaq End of Run 11967:
232087 05/06/11 08:19 cdaq Moller Run 1141: DAQ test
232086 05/06/11 08:07 Korkmaz Shift Summary: owl shift summary
232085 05/06/11 08:05 cdaq Beam Time Accounting
232084 05/06/11 07:35 qwanalysis Analysis: Run 11967 - Plots and Summary Table for 100k Events.
232083 05/06/11 07:21 cdaq Compton Run 21922 (standard): Beam profile {scan;} Y=0.62mm
232082 05/06/11 07:21 cdaq Run 11967: LH2 production at 165 uA, IHWP IN
232081 05/06/11 07:20 cdaq Compton End of Run 21921 (standard):
232080 05/06/11 07:20 cdaq End of Run 11966:
232079 05/06/11 06:32 qwanalysis Analysis: Run 11966 - Plots and Summary Table for 100k Events.
232078 05/06/11 06:28 Korkmaz FlipPCValues output values just before run 11966
232077 05/06/11 06:21 cdaq Compton Run 21921 (standard): Beam profile {scan;} Y=0.62mm
232076 05/06/11 06:20 Korkmaz IHWP IN
232075 05/06/11 06:19 cdaq Run 11966: LH2 production at 165 uA, IHWP IN (transition run)
232074 05/06/11 06:15 cdaq Compton End of Run 21920 (standard):
232073 05/06/11 06:14 cdaq End of Run 11965:
232072 05/06/11 06:10 Korkmaz GT and HV plots
232071 05/06/11 05:30 qwanalysis Analysis: Run 11965 - Plots and Summary Table for 100k Events.
232070 05/06/11 05:15 cdaq Compton Run 21920 (standard): Beam profile {scan;} Y=0.62mm
232069 05/06/11 05:14 cdaq Run 11965: LH2 production at 165 uA, IHWP OUT
232068 05/06/11 05:11 Korkmaz a bit more on halo rates
232067 05/06/11 05:02 Korkmaz QTOR reset locally
232066 05/06/11 04:47 qwanalysis Analysis: Run 11964 - Plots and Summary Table for 100k Events.
232065 05/06/11 04:45 Korkmaz QTOR trip
232064 05/06/11 04:35 cdaq End of Run 11964:
232063 05/06/11 04:35 cdaq Compton End of Run 21919 (standard):
232062 05/06/11 04:29 cdaq Run 11964: LH2 production at 165 uA, IHWP OUT
232061 05/06/11 04:23 cdaq End of Run 11963:
232060 05/06/11 04:10 cdaq Compton Run 21919 (standard): Beam profile {scan;} Y=0.62mm
232059 05/06/11 04:09 cdaq Compton End of Run 21918 (standard):
232058 05/06/11 03:59 Korkmaz halo monitors' rates
232057 05/06/11 03:39 qwanalysis Analysis: Run 11963 - Plots and Summary Table for 100k Events.
232056 05/06/11 03:19 cdaq Run 11963: LH2 production at 165 uA, IHWP OUT
232055 05/06/11 03:17 cdaq End of Run 11962:
232054 05/06/11 02:53 cdaq Compton Run 21918 (standard): Beam profile {scan;} Y=0.62mm
232053 05/06/11 02:53 cdaq Compton End of Run 21917 (standard):
232052 05/06/11 02:27 qwanalysis Analysis: Run 11962 - Plots and Summary Table for 100k Events.
232051 05/06/11 02:23 Korkmaz cdaql5 disk almost full
232050 05/06/11 02:13 cdaq Run 11962: LH2 production at 170uA, IHWP OUT
232049 05/06/11 02:12 cdaq End of Run 11961:
232048 05/06/11 01:37 cdaq Compton Run 21917 (standard): Beam profile {scan;} Y=0.62mm
232047 05/06/11 01:36 cdaq Compton End of Run 21916 (standard):
232046 05/06/11 01:19 qwanalysis Analysis: Run 11961 - Plots and Summary Table for 100k Events.
232045 05/06/11 01:04 cdaq Run 11961: LH2 production at 170uA, IHWP OUT
232044 05/06/11 01:04 cdaq End of Run 11960:
232043 05/06/11 00:30 cdaq Compton Run 21916 (standard): Beam profile scan; Y=0.62mm
232042 05/06/11 00:25 cdaq Compton End of Run 21915 (standard):
232041 05/06/11 00:25 L.Lee Target: Tweaked 15K JT valve
232040 05/06/11 00:18 cdaq Beam Time Accounting
232039 05/06/11 00:17 qwanalysis Analysis: Run 11960 - Plots and Summary Table for 100k Events.
232038 05/06/11 00:09 L.Lee Target: Target GUI and strip charts screenshots at start of owl shift
232037 05/06/11 00:08 sxyang screenshots of GeneralTool and HV GUI
0 05/06/11 00:07 cdaq Compton Run 21915 (standard): Y=0.74mm {;} All eDet planes @500V
232035 05/06/11 00:06 cdaq Compton End of Run 21914 (standard):
232034 05/06/11 00:06 sxyang Summary of Swing shift
232033 05/06/11 00:03 cdaq Run 11960: LH2 production at 170uA, IHWP OUT
232032 05/06/11 00:02 cdaq End of Run 11959:
Thursday
232031 05/05/11 23:57 beaufait target shift summery
232030 05/05/11 23:27 qwanalysis Analysis: Run 11959 - Plots and Summary Table for 100k Events.
232029 05/05/11 23:13 cdaq Beam Time Accounting
232028 05/05/11 23:08 cdaq Compton End of Run 21913 (standard):
232027 05/05/11 23:01 cdaq Run 11959: LH2 production at 170uA
232026 05/05/11 23:00 cdaq End of Run 11958:
232025 05/05/11 22:47 narayan Compton: eDet voltage for all planes = -500V
232024 05/05/11 22:37 beaufait Bellows temp
232023 05/05/11 22:17 cdaq Compton Run 21913 (standard): HWP OUT
232022 05/05/11 22:15 qwanalysis Analysis: Run 11958 - Plots and Summary Table for 100k Events.
232021 05/05/11 22:15 donjones Compton: Vertical scan: new YPOS=0.62mm
232020 05/05/11 21:58 cdaq Run 11958: LH2 production at 170uA
232019 05/05/11 21:57 cdaq End of Run 11957:
232018 05/05/11 21:40 qwanalysis Analysis: Run 11957 - Plots and Summary Table for 100k Events.
232017 05/05/11 21:21 buddhini Started analysis of bpm pedestal run 11956 on cdaql3
232016 05/05/11 21:11 buddhini Started injector run 2401 at 21.07
232015 05/05/11 21:07 qwanalysis Analysis: Run 11956 - Plots and Summary Table for 100k Events.
232014 05/05/11 21:02 sxyang back to production run
232013 05/05/11 20:59 buddhini Turned on modulation and qwfeedback
232012 05/05/11 20:58 buddhini Turned on compton detector
232011 05/05/11 20:57 cdaq Run 11957: LH2 production at 170uA
232010 05/05/11 20:43 buddhini Moving electron detector to BEAM position
232009 05/05/11 20:42 buddhini IOCSE 18 and 20 are back in auto gain mode
232008 05/05/11 20:40 buddhini IOCES 14 and 17 are back in auto gain mode
232007 05/05/11 20:32 buddhini Ended tje BPM pedestal scan program.
232006 05/05/11 20:30 cdaq End of Run 11956:
232005 05/05/11 20:27 buddhini Current ranget used for the BPM scan : 120 uA to 170 uA.
232004 05/05/11 20:18 buddhini Late enrty : Don turned off the Comtpon detector before we began BPM pedestal scan program
232003 05/05/11 20:13 buddhini Current, FB status and halo rates during BPM scan
232002 05/05/11 19:55 rakithab Unusual yield distribution for MD1 Neg and MD3 Pos during the frist 100K of the run 11953
232001 05/05/11 19:51 sxyang screenshots of iocsel 14 and 20
232000 05/05/11 19:50 sxyang screenshots of iocsel 17 and 18
231999 05/05/11 19:50 cdaq Run 11956: BPM calibration
231998 05/05/11 19:49 cdaq End of Run 11955:
231997 05/05/11 19:49 cdaq Run 11955: test
231996 05/05/11 19:45 qwanalysis Analysis: Run 11954 - Plots and Summary Table for 100k Events.
231995 05/05/11 19:35 buddhini Turned off beam modulation and feedback
231994 05/05/11 19:31 cdaq End of Run 11954:
231993 05/05/11 19:27 sxyang screenshots of iocsel 20
231992 05/05/11 19:26 sxyang screenshots of iocse17 and iocsel18
231991 05/05/11 19:23 buddhini IOSCE 14 Live display
231990 05/05/11 19:23 cdaq Run 11954: Test run at 175uA 4x4 raster
231989 05/05/11 19:20 cdaq End of Run 11953:
231988 05/05/11 19:19 buddhini Starting BPM pedestal scan program
231987 05/05/11 19:19 qwanalysis Analysis: Run 11953 - Plots and Summary Table for 100k Events.
231986 05/05/11 18:57 sxyang ion chamber works well
231985 05/05/11 18:57 beaufait When IOC15 was rebooted at 1900
231984 05/05/11 18:56 cdaq Run 11953: Beam back at 165uA
231983 05/05/11 18:55 cdaq End of Run 11952:
231982 05/05/11 18:54 cdaq Run 11952: pulsed LED calibration, LED 8-
231981 05/05/11 18:51 sxyang changed the bcm 1/2 gains setting
231980 05/05/11 18:43 jhlee 4 autoanalyzers are running on cdaql5, re-enable them in cronjob
231979 05/05/11 18:33 cdaq End of Run 11951:
231978 05/05/11 18:31 pking Analysis: Switched main analyzer version on cdaq cluster back to 1.08rc4
231977 05/05/11 18:29 cdaq Run 11951: Test run with Beam ON
231976 05/05/11 18:25 benesch hall C dump camera gives nothing
231975 05/05/11 17:48 sxyang testing the ion chamber
231974 05/05/11 16:54 cdaq Moller Run 1140: DAQ test - gate generator re-installed
231973 05/05/11 16:52 gaskell Moller: replaced gate generator for MPS
231972 05/05/11 16:32 sxyang called for a full sweep
231971 05/05/11 16:31 gaskell Compton: ion chamber removed
231970 05/05/11 16:19 gaskell Moller: field in Q2
231969 05/05/11 15:37 vanoers snapshots of high voltage and general tools
231968 05/05/11 15:35 cdaq Compton End of Run 21912 (standard):
231967 05/05/11 15:15 dalton Compton: Flipper mirror swapped out
231966 05/05/11 15:09 kamyers has bcm gain been switched back to 2?
231965 05/05/11 15:01 rob MD current-mode restored; ready for high-current operation
231964 05/05/11 14:48 rakithab Target: GUI and strip charts screenshots
231963 05/05/11 14:42 rob swapped out md3+ current-mode HV cable for spare in hall
231962 05/05/11 14:30 vanoers Retraction of VDC's
231961 05/05/11 14:25 Leckey R3 Retracted
231960 05/05/11 14:20 jhlee event mode runs are marks as "not to be analyzed"
231959 05/05/11 13:55 benesch update on ion chamber work posted to elog by Michaud; I copy here
231958 05/05/11 13:50 rob done with MD event-mode; entering the hall to convert to current-mode
231957 05/05/11 13:44 cdaq End of Run 11950:
231956 05/05/11 13:43 cdaq Run 11950: pulsed LED calibration, LED 1-
231955 05/05/11 13:40 cdaq End of Run 11949:
231954 05/05/11 13:40 cdaq Run 11949: pulsed LED calibration, LED 1-
231953 05/05/11 13:37 cdaq Run 11948: pulsed LED calibration, LED 1-
231952 05/05/11 13:34 cdaq End of Run 11947:
231951 05/05/11 13:33 cdaq Run 11947: pulsed LED calibration, LED 2-
231950 05/05/11 13:30 cdaq Run 11946: pulsed LED calibration, LED 2-
231949 05/05/11 13:26 cdaq Run 11945: pulsed LED calibration, LED 3-
231948 05/05/11 13:25 gaskell Moller: Hall probes installed in big quad
231947 05/05/11 13:24 cdaq End of Run 11944:
231946 05/05/11 13:23 cdaq Run 11944: pulsed LED calibration, LED 3-
231945 05/05/11 13:22 cdaq Run 11943: pulsed LED calibration, LED 4-
231944 05/05/11 13:20 cdaq End of Run 11943:
231943 05/05/11 13:18 cdaq End of Run 11942:
231942 05/05/11 13:18 cdaq Run 11942: pulsed LED calibration, LED 4-
231941 05/05/11 13:15 cdaq End of Run 11941:
231940 05/05/11 13:15 cdaq Run 11941: pulsed LED calibration, LED 5-
231939 05/05/11 13:14 cdaq Run 11941: pulsed LED calibration, LED 5-
231938 05/05/11 13:13 cdaq End of Run 11940:
231937 05/05/11 13:07 cdaq End of Run 11939:
231936 05/05/11 13:06 cdaq Run 11939: pulsed LED calibration, LED 6-
231935 05/05/11 13:02 cdaq Run 11938: pulsed LED calibration, LED 6-
231934 05/05/11 12:59 cdaq End of Run 11937:
231933 05/05/11 12:59 cdaq Run 11937: pulsed LED calibration, LED 6-
231932 05/05/11 12:55 cdaq End of Run 11936:
231931 05/05/11 12:55 cdaq Run 11936: pulsed LED calibration, LED 7-
231930 05/05/11 12:52 cdaq End of Run 11935:
231929 05/05/11 12:52 cdaq Run 11935: pulsed LED calibration, LED 7-
231928 05/05/11 12:49 cdaq End of Run 11934:
231927 05/05/11 12:48 cdaq Run 11934: pulsed LED calibration, LED 8-
231926 05/05/11 12:46 cdaq End of Run 11933:
231925 05/05/11 12:45 cdaq Run 11933: pulsed LED calibration, LED 8-
231924 05/05/11 12:42 cdaq End of Run 11932:
231923 05/05/11 12:42 cdaq Run 11932: pulsed LED calibration, LED 8-
231922 05/05/11 12:34 cdaq Compton Run 21912 (standard): no {beam;} consistency check amongst actrig=1/3, evtrig=2/3, 1/3 scalers
231921 05/05/11 12:25 cdaq Compton End of Run 21911 (standard):
231920 05/05/11 12:08 cdaq End of Run 11931:
231919 05/05/11 12:07 cdaq Run 11931: pulsed LED calibration, LED 5+
231918 05/05/11 11:54 cdaq Compton Run 21911 (standard): no {beam;} consistency check amongst actrig=3/3, evtrig=2/3, 1/3 scalers
231917 05/05/11 11:32 smithg Target: target motion plot
231916 05/05/11 11:30 cdaq Compton End of Run 21910 (standard):
231915 05/05/11 11:14 cdaq End of Run 11930:
231914 05/05/11 11:14 cdaq Run 11930: pulsed LED calibration, LED 5+
231913 05/05/11 11:12 cdaq End of Run 11929:
231912 05/05/11 11:12 cdaq Run 11929: pulsed LED calibration, LED 5+
231911 05/05/11 11:08 cdaq End of Run 11928:
231910 05/05/11 11:07 cdaq Run 11928: pulsed LED calibration, LED 8+
231909 05/05/11 11:07 cdaq Compton Run 21910 (standard): no beam; consistency check amongst actrig=2/3, evtrig=3/3, 1/3 scalers
231908 05/05/11 11:04 cdaq End of Run 11927:
231907 05/05/11 11:04 rob restarted coda after several event builder crashes
231906 05/05/11 11:03 cdaq Run 11927: pulsed LED calibration, LED 8+
231905 05/05/11 10:57 cdaq Run 11926: pulsed LED calibration, LED 7+
231904 05/05/11 10:54 cdaq Run 11925: pulsed LED calibration, LED 7+
231903 05/05/11 10:51 cdaq End of Run 11924:
231902 05/05/11 10:50 cdaq Run 11924: pulsed LED calibration, LED 6+
231901 05/05/11 10:48 cdaq End of Run 11923:
231900 05/05/11 10:47 cdaq Run 11923: pulsed LED calibration, LED 6+
231899 05/05/11 10:42 cdaq Run 11922: pulsed LED calibration, LED 5+
231898 05/05/11 10:39 cdaq End of Run 11921:
231897 05/05/11 10:39 cdaq Run 11921: pulsed LED calibration, LED 5+
231896 05/05/11 10:33 cdaq End of Run 11920:
231895 05/05/11 10:32 cdaq Run 11920: pulsed LED calibration, LED 4+
231894 05/05/11 10:29 cdaq End of Run 11919:
231893 05/05/11 10:29 cdaq Run 11919: pulsed LED calibration, LED 4+
231892 05/05/11 10:25 cdaq End of Run 11918:
231891 05/05/11 10:23 cdaq Run 11918: pulsed LED calibration, LED 4+
231890 05/05/11 10:18 cdaq End of Run 11917:
231889 05/05/11 10:17 cdaq Run 11917: pulsed LED calibration, LED 3+
231888 05/05/11 10:12 cdaq End of Run 11916:
231887 05/05/11 10:11 cdaq Run 11916: pulsed LED calibration, LED 3+
231886 05/05/11 10:03 cdaq End of Run 11915:
231885 05/05/11 10:02 cdaq Run 11915: pulsed LED calibration, LED 2+
231884 05/05/11 09:59 brads Please clean up /w/hallc/qweak disk, it is 100% full
231883 05/05/11 09:52 cdaq End of Run 11914:
231882 05/05/11 09:51 cdaq Run 11914: pulsed LED calibration, LED 2+
231881 05/05/11 09:43 smithg Target: evaporator ice is gone
231880 05/05/11 09:42 smithg target motions last night
231879 05/05/11 09:38 dunne Restricted Access
231878 05/05/11 09:29 cdaq End of Run 11913:
231877 05/05/11 09:28 cdaq Run 11913: pulsed LED calibration, md1+
231876 05/05/11 09:17 cdaq End of Run 11912:
231875 05/05/11 09:16 cdaq Run 11912: pulsed LED calibration, md1+
231874 05/05/11 09:06 jhlee change analysis stauts from run 11872 to 11901 as not to be analyzed
231873 05/05/11 08:39 rob background HV off; MD HV on; setting up for pulsed LED calibration
231872 05/05/11 08:04 cdaq Beam Time Accounting
231871 05/05/11 08:00 Korkmaz Shift Summary: Owl shift summary
231870 05/05/11 07:46 rob added background detectors to HV GUIs
231869 05/05/11 07:19 cdaq Run 11911: background telescope, OR trigger, qtor off, beam off
231868 05/05/11 07:07 cdaq End of Run 11910:
231867 05/05/11 07:03 cdaq Run 11910: background telescope, OR trigger, qtor off, beam off
231866 05/05/11 07:02 cdaq Beam Time Accounting
231865 05/05/11 07:01 cdaq End of Run 11909:
231864 05/05/11 06:58 cdaq Run 11909: background telescope, OR trigger, qtor off
231863 05/05/11 06:56 cdaq End of Run 11908:
231862 05/05/11 06:50 cdaq Run 11908: background telescope, AND trigger, qtor off
231861 05/05/11 06:49 cdaq End of Run 11907:
231860 05/05/11 06:45 cdaq Run 11907: background telescope, AND trigger, qtor off
231859 05/05/11 06:43 cdaq End of Run 11906:
231858 05/05/11 06:41 cdaq Run 11906: background telescope, AND trigger, during qtor ramp
231857 05/05/11 06:38 rob runs 11904 and 11905 had .AND. trigger
231856 05/05/11 06:37 rob ramping qtor to zero
231855 05/05/11 06:37 cdaq End of Run 11905:
231854 05/05/11 06:29 cdaq Run 11905: background telescope, OR trigger
231853 05/05/11 06:28 cdaq End of Run 11904:
231852 05/05/11 06:24 cdaq Run 11904: background telescope, OR trigger
231851 05/05/11 06:23 cdaq End of Run 11903:
231850 05/05/11 06:21 Korkmaz Beam will be off at 7:00 am for beam studies
231849 05/05/11 06:20 cdaq Run 11903: background telescope, wilbur trigger
231848 05/05/11 06:19 cdaq End of Run 11902:
231847 05/05/11 06:12 cdaq Run 11902: background telescope, OR trigger
231846 05/05/11 05:48 kamyers EM Aluminum running done, still on BCM gain 5
231845 05/05/11 05:44 L.Lee Target: Move back to Hydrogen-Cell target
231844 05/05/11 05:42 cdaq End of Run 11901:
231843 05/05/11 05:38 cdaq Run 11901: Beam off
231842 05/05/11 05:36 cdaq End of Run 11900:
231841 05/05/11 05:33 cdaq Run 11900: 8% DS Al QTOR 8921
231840 05/05/11 05:31 cdaq End of Run 11899:
231839 05/05/11 05:28 cdaq Run 11899: 8% DS Al QTOR 6700
231838 05/05/11 05:27 L.Lee Target: Move to DS-8%-Al
231837 05/05/11 05:23 cdaq End of Run 11898:
231836 05/05/11 05:21 cdaq Run 11898: US Pure Al QTOR 6700
231835 05/05/11 05:10 cdaq End of Run 11897:
231834 05/05/11 05:07 cdaq Run 11897: US Pure Al QTOR 8921
231833 05/05/11 05:06 cdaq End of Run 11896:
231832 05/05/11 05:05 L.Lee Target: Move to US-Pure-Al
231831 05/05/11 05:04 cdaq Run 11896: Beam off
231830 05/05/11 05:02 cdaq End of Run 11895:
231829 05/05/11 04:22 cdaq Run 11895: 1% US Al QTOR Scan continued
231828 05/05/11 04:20 cdaq End of Run 11894:
231827 05/05/11 04:08 cdaq Run 11894: 1% US Al QTOR Scan
231826 05/05/11 04:05 cdaq End of Run 11893:
231825 05/05/11 04:02 cdaq Run 11893: Beam off
231824 05/05/11 04:01 kamyers Interesting halo/ts rate dependence on raster size
231823 05/05/11 03:59 L.Lee Target: Move to US-1%-Al
231822 05/05/11 03:56 cdaq End of Run 11892:
231821 05/05/11 03:53 cdaq Run 11892: 4% US Al QTOR 6700
231820 05/05/11 03:49 cdaq End of Run 11891:
231819 05/05/11 03:34 cdaq Run 11891: 4% US Al - Raster Scan
231818 05/05/11 03:30 cdaq End of Run 11890:
231817 05/05/11 03:16 cdaq Run 11890: 4% US Al QTOR Scan (Hall A now at 120 uA)
231816 05/05/11 03:14 L.Lee Target: Move to US-4%-Al
231815 05/05/11 03:14 kamyers DS Centering raster map
231814 05/05/11 03:11 cdaq End of Run 11889:
231813 05/05/11 03:07 cdaq Run 11889: DS Centering target (Hall A now at 120 uA)
231812 05/05/11 03:04 L.Lee Target: Move to DS-Centering-Hole
231811 05/05/11 03:00 cdaq End of Run 11888:
231810 05/05/11 02:57 cdaq Run 11888: 8% US Al, QTOR 8921
231809 05/05/11 02:54 cdaq End of Run 11887:
231808 05/05/11 02:52 cdaq Run 11887: 8% US Al, QTOR 6700
231807 05/05/11 02:50 L.Lee Target: Move to DS-8%-Al
231806 05/05/11 02:47 cdaq End of Run 11886:
231805 05/05/11 02:44 cdaq Run 11886: 2% US Al, QTOR 6700
231804 05/05/11 02:41 cdaq End of Run 11885:
231803 05/05/11 02:40 kamyers run 11883 beam off run
231802 05/05/11 02:38 cdaq Run 11885: 2% US Al, QTOR 8921
231801 05/05/11 02:37 L.Lee Target: Move to US-2%-Al
231800 05/05/11 02:32 cdaq End of Run 11884:
231799 05/05/11 02:30 cdaq Run 11884: DS Be
231798 05/05/11 02:28 cdaq End of Run 11883:
231797 05/05/11 02:27 L.Lee Target: Move to DS-2%-Be
231796 05/05/11 02:27 cdaq Run 11883: DS Be
231795 05/05/11 02:24 cdaq End of Run 11882:
231794 05/05/11 01:58 cdaq Run 11882: 4% DS Aluminum QTOR Scan part 3
231793 05/05/11 01:48 cdaq End of Run 11881:
231792 05/05/11 01:46 cdaq Run 11881: Raster map, 4% DS Al
231791 05/05/11 01:32 kamyers work disk on the farm filled
231790 05/05/11 01:31 cdaq End of Run 11880:
231789 05/05/11 01:17 cdaq Run 11880: 4% DS Aluminum, QTOR Scan Part 2
231788 05/05/11 01:16 cdaq End of Run 11879:
231787 05/05/11 00:55 cdaq Run 11879: 4% DS Aluminum, QTOR Scan Part 1
231786 05/05/11 00:49 L.Lee Target: Move to DS-4%-Al
231785 05/05/11 00:46 cdaq End of Run 11878:
231784 05/05/11 00:44 cdaq Run 11878: 8% DS Aluminum, QTOR 6700
231783 05/05/11 00:41 cdaq End of Run 11877:
231782 05/05/11 00:38 cdaq Run 11877: 8% DS Aluminum, QTOR 8921
231781 05/05/11 00:35 L.Lee Target: Alarm Handler Limits for H2 Downstream beamline vacuum
231780 05/05/11 00:30 cdaq Run 11876: Beam off (slit open - Hall A at 40 uA)
231779 05/05/11 00:27 cdaq End of Run 11875:
231778 05/05/11 00:26 L.Lee Target: Target GUI and strip charts screenshots at start of owl shift
231777 05/05/11 00:25 L.Lee Target: Move from LH2 cell to DS-8%-Al target
231776 05/05/11 00:24 cdaq Run 11875: Beam off (slit closed)
231775 05/05/11 00:21 jhlee turned off autoanalyzers on cdaql5, switch main analyzer to trunk version on cdaq cluster
231774 05/05/11 00:20 cdaq End of Run 11874:
231773 05/05/11 00:16 Spayde Sent Scanner Home and Turned Off Motion Controller
231772 05/05/11 00:13 mack setting up for 120 nA Aluminum running
231771 05/05/11 00:10 mack bcm1,2 gain settings to 5
231770 05/05/11 00:09 cdaq Run 11874: DAQ test
231769 05/05/11 00:06 cdaq Run 11873: Junk
231768 05/05/11 00:06 cdaq Run 11872: Junk
231767 05/05/11 00:05 Spayde Shift Summary: Swing Shift Summary 05/04/2011
Wednesday
231766 05/04/11 23:52 Armstrong VDC HVs turned off
231765 05/04/11 23:46 jhlee turned off ROC9/10 to switch back to parity DAQ
231764 05/04/11 23:44 jhlee DAQ crashes (ROC9/10, EB4/ER4)
231763 05/04/11 23:44 Spayde Shut Off Scanner HV. Scanner Still Parked in Middle of Bar.
231762 05/04/11 23:43 Armstrong Rate too large for ROCs
231761 05/04/11 23:35 jhlee DAQ crashes (ROC9)
231760 05/04/11 23:35 cdaq Run 11871: Tracking Run: Octant 1 and 5, 10? nA
231759 05/04/11 23:34 Armstrong raised beam current
231757 05/04/11 23:30 cdaq Run 11870: Tracking Run: Octant 1 and 5, 10? nA
231756 05/04/11 23:23 jhlee Wire Hit plots for Vader, Leia, Yoda, and Han
231755 05/04/11 22:58 cdaq Run 11869: Tracking Run: Octant 1 and 5, 10? nA
231754 05/04/11 22:57 cdaq End of Run 11868:
231753 05/04/11 22:55 cdaq Run 11868: Tracking Run: Octant 1 and 5, 10? nA
231752 05/04/11 22:49 Armstrong Rotate VDCs to Octants 5 and 1
231751 05/04/11 22:48 Spayde Done in Hall. Asked for Beam.
231750 05/04/11 22:47 Spayde Shift Checklist Screenshots
231749 05/04/11 22:31 Spayde Requested Access to Rotate Chambers
231748 05/04/11 22:30 cdaq End of Run 11867:
231747 05/04/11 22:16 mack comments on Al event mode run plan
231746 05/04/11 22:15 sxyang vdc plots from tracking run 11865
231745 05/04/11 22:07 cdaq Run 11867: Tracking Run: Octant 3 and 7, 10? nA, Scanner Triggered
231744 05/04/11 22:06 cdaq End of Run 11866:
231743 05/04/11 22:02 Spayde Moved Scanner
231742 05/04/11 21:51 cdaq Run 11866: Tracking Run: Octant 3 and 7, 10? nA
231741 05/04/11 21:51 sxyang vader and leia
231740 05/04/11 21:51 cdaq End of Run 11865:
231739 05/04/11 21:49 cdaq Run 11865: Tracking Run: Octant 3 and 7, 10? nA
231738 05/04/11 21:39 Armstrong VDCs rotated to 7 & 3
231737 05/04/11 21:24 hamlet Target: Target GUI and strip charts screenshots for Swing shift
231736 05/04/11 21:22 sxyang vdc plots from run 11864
231735 05/04/11 21:21 Spayde Requested Access to Rotate R3 Chambers
231734 05/04/11 21:13 cdaq End of Run 11864:
231733 05/04/11 20:58 cdaq Run 11864: Tracking Run: Octant 6 and 2, 10? nA
231732 05/04/11 20:45 Armstrong VDCs rotated to 6 & 2
231731 05/04/11 20:45 Spayde R3 Rotated. Requested Beam
231730 05/04/11 20:30 rob scanner to 0,0; motion controller off; HV still on
231729 05/04/11 20:28 cdaq End of Run 11863:
231728 05/04/11 20:28 Spayde Requested Escorted Access to Rotate R3 Chambers
231727 05/04/11 20:15 Armstrong VDCs tripped; reset
231726 05/04/11 20:11 cdaq Run 11863: Tracking Run: Octant 4 and 8, 10? nA Scanner slow vertical stripe
231725 05/04/11 20:11 rakithab Changed the first100k tracking setup wrapper class to run the script using a trunk revision of the analyzer
231724 05/04/11 20:10 cdaq End of Run 11862:
231723 05/04/11 20:06 sxyang vdc plots from tracking run 11861
231722 05/04/11 20:05 rakithab devel qwtracking is not working
231721 05/04/11 20:02 Armstrong Rotated VDCs to 3 & 7
231720 05/04/11 19:49 cdaq Run 11862: Tracking Run: Octant 4 and 8, 10? nA Scanner 0,-90
231719 05/04/11 19:47 cdaq End of Run 11861:
231718 05/04/11 19:37 sxyang vdc plots for tracking run 11857
231717 05/04/11 19:34 cdaq Run 11861: Tracking Run: Octant 3 and 7, 10? nA
231716 05/04/11 19:31 cdaq End of Run 11860:
231715 05/04/11 19:29 cdaq Run 11860: Tracking DAQ Test
231714 05/04/11 19:23 cdaq End of Run 11859:
231713 05/04/11 19:22 Spayde Done Rotating R3. Asked For Beam.
231712 05/04/11 19:22 cdaq Run 11859: Tracking DAQ Test
231711 05/04/11 19:11 Spayde Turning On Scanner Scintillator HVs to 1500 V
231710 05/04/11 19:08 rob scanner motion controller on; scanner homing
231709 05/04/11 19:04 rob md data checkout with run 11857
231708 05/04/11 18:59 Armstrong VDCs on, data OK
231707 05/04/11 18:57 cdaq End of Run 11858:
231706 05/04/11 18:53 Spayde Requested Escorted Access to Rotate R3 Chambers
231705 05/04/11 18:52 cdaq Moller Run 1138: Moller DAQ test - looking for helicity PANIC
231704 05/04/11 18:48 Armstrong Slit/attenuator beam settings
231703 05/04/11 18:22 rob md event-mode checkout
231702 05/04/11 18:21 cdaq Run 11858: Tracking Run: Octant 4 and 8, 10? nA
231701 05/04/11 18:20 cdaq End of Run 11857:
231700 05/04/11 18:20 cdaq Run 11857: Tracking Run: Octant 4 and 8, 10? nA
231699 05/04/11 18:19 cdaq End of Run 11856:
231698 05/04/11 18:18 cdaq Run 11856: Tracking Run: Octant 4 and 8, 10? nA
231697 05/04/11 18:18 Armstrong VDCs on at 3800 V
231696 05/04/11 18:15 cdaq Moller Run 1137: Moller DAQ test - looking for helicity PANIC
231695 05/04/11 18:10 cdaq Moller Run 1136: Moller DAQ test - looking for helicity PANIC
231694 05/04/11 18:10 kamyers Aluminum tracking mode run plan for tonight
231693 05/04/11 18:04 hamlet Target: Target: Put Hydrogen target in
231692 05/04/11 18:02 Spayde Using Fake MPS.
231691 05/04/11 18:00 cdaq Run 11855: Tracking Run with Main Detector as Trigger, No Beam
231690 05/04/11 17:59 Armstrong VDCs into position: 4 & 8
231689 05/04/11 17:56 Spayde Ramping Up QTOR. Turned on Trigger and Halo Scintillators.
231688 05/04/11 17:56 cdaq Moller Run 1135: Moller DAQ test - looking for helicity PANIC
231687 05/04/11 17:46 Spayde/Mahur Turned on MD Event Mode HV
231686 05/04/11 17:34 cdaq Moller Run 1134: Moller DAQ test - looking for helicity PANIC
231685 05/04/11 17:33 gaskell Moller tune - quad problems
231684 05/04/11 17:28 Spayde Switching to Tracking DAQ
231683 05/04/11 17:26 cdaq End of Run 11854:
231682 05/04/11 17:25 cdaq Run 11854: Tracking DAQ Test
231681 05/04/11 17:10 gaskell/mage Moller results for May 4, 2011
231680 05/04/11 16:59 smithg found ramp rate at 2.5 uA/s again
231679 05/04/11 16:59 Spayde Switching to Tracking. Requesting Controlled Access.
231678 05/04/11 16:52 magee Moller finished - backing out
231677 05/04/11 16:29 cdaq Moller Run 1133: IHWP=OUT Production - current reduced with slit
231676 05/04/11 16:22 cdaq Moller Run 1132: IHWP=OUT Production - current reduced with slit
231675 05/04/11 16:21 gaskell Moller: removed gatre generator from MPS electronics chain
231674 05/04/11 16:17 cdaq Moller Run 1131: IHWP=OUT Production - current reduced with slit
231673 05/04/11 16:09 cdaq Moller Run 1130: IHWP=OUT Production - current reduced with slit
231672 05/04/11 16:08 cdaq Beam Time Accounting
231671 05/04/11 16:08 cdaq Moller Run 1129: IHWP=OUT Production - current reduced with slit
231670 05/04/11 16:05 cdaq Moller Run 1128: IHWP=OUT Production - current reduced with slit
231669 05/04/11 16:02 cdaq Moller Run 1127: IHWP=OUT Production - current reduced with slit
231668 05/04/11 15:57 buddhini Target: Target GUI and strip charts screenshots at the end of day shift
231667 05/04/11 15:55 buddhini Snapshots of HV and General Tools
231666 05/04/11 15:54 cdaq Moller Run 1126: IHWP=OUT Production - current reduced with slit
231665 05/04/11 15:54 buddhini Flipped the PC values for IHWP OUT state (for Moller)
231664 05/04/11 15:41 cdaq Moller Run 1125: IHWP=IN Production - current reduced with slit
231663 05/04/11 15:39 vanoers Shift Summary: Daytime shift
231662 05/04/11 15:38 cdaq Moller Run 1124: IHWP=IN Production - current reduced with slit
231661 05/04/11 15:34 cdaq Moller Run 1123: IHWP=IN Production - current reduced with slit
231660 05/04/11 15:29 cdaq Moller Run 1122: IHWP=IN Production - current reduced with slit
231659 05/04/11 15:23 cdaq Moller Run 1121: IHWP=IN Production - current reduced with slit
231658 05/04/11 15:19 cdaq Moller Run 1120: IHWP=IN Production - current reduced with slit
231657 05/04/11 15:17 cdaq Moller Run 1119: IHWP=IN Production - current reduced with slit
231656 05/04/11 15:06 cdaq Moller Run 1118: IHWP=IN Production
231655 05/04/11 15:01 cdaq Moller Run 1117: IHWP=IN Production
231654 05/04/11 14:53 jhlee update BCM5/6 calibration constants on cdaq cluster
231653 05/04/11 14:53 cdaq Moller Run 1116: IHWP=IN Production
231652 05/04/11 14:50 cdaq Moller Run 1115: Tune check.
231651 05/04/11 14:41 cdaq Moller Run 1114: IHWP=IN Production
231650 05/04/11 14:34 cdaq Moller Run 1113: IHWP=IN Production
231649 05/04/11 14:31 cdaq Moller Run 1112: IHWP=IN Production
231648 05/04/11 14:28 cdaq Moller Run 1111: Tune check
231647 05/04/11 14:14 cdaq Moller Run 1110: Tune check
231646 05/04/11 14:08 cdaq Moller Run 1109: Tune check
231645 05/04/11 14:04 cdaq Moller Run 1108: DAQ TEST.
231644 05/04/11 13:54 gaskell Moller restart
231643 05/04/11 13:48 smithg Target: Please leave ramp rate at 5 uA/s
231642 05/04/11 13:33 buddhini Target: Moved to HOME.
231641 05/04/11 13:30 vanoers Ion Chamber tests completed
231640 05/04/11 13:24 buddhini Target: Moved to LH2.
231639 05/04/11 13:13 rob dosimetry installed along cable tray
231638 05/04/11 13:13 magee Target GUI white out- reboot IOC
231637 05/04/11 12:25 vanoers Beam: Placing dosimeters on the cable tray close to the beam dump
231636 05/04/11 12:13 vanoers Beam: Second controlled acess this morning
231635 05/04/11 12:07 buddhini Target: Tareget screen shots
231634 05/04/11 11:38 buddhini Target: Correction: the beam on DS 0.5% C beam will be rastered (4x4 ) < 30 uA.
231633 05/04/11 11:29 buddhini Target: Target moved to DS 0.5% C target
231632 05/04/11 11:23 magee Solenoid ramping down...
231631 05/04/11 10:46 buddhini Hall is in power permit
231630 05/04/11 10:40 Ramesh Analysis: Cavity bcm calibration using run 11840
231629 05/04/11 10:23 gaskell No water leaks
231628 05/04/11 10:15 covrig small correction to owl shift summary
231627 05/04/11 09:26 buddhini Hall is in controlled access.
231626 05/04/11 09:20 buddhini QTOR ramping down to zero
231625 05/04/11 09:19 benesch right ion chamber response decayed overnight
231624 05/04/11 08:59 magee Beam down ~ hour to work on ion chambers
231623 05/04/11 08:22 magee Moller set-up
231622 05/04/11 08:22 buddhini Target: Moved to Home.
231621 05/04/11 08:21 magee Qweak HV and BMod off for Moller
231620 05/04/11 08:17 qwanalysis Analysis: Run 11853 - Plots and Summary Table for 100k Events.
231619 05/04/11 08:15 cdaq Moller Run 1107: DAQ TEST.
231618 05/04/11 08:10 cdaq End of Run 11853:
231617 05/04/11 08:08 Korkmaz Shift Summary: Owl shift summary
231616 05/04/11 08:06 cdaq Beam Time Accounting
231615 05/04/11 08:02 magee Moller set-up injector parameters
231614 05/04/11 07:59 rajotte position differences flirting with 150nm again
231613 05/04/11 07:49 Korkmaz Dump right ion chamber is tripping frequently - beam current reduced
231612 05/04/11 07:43 rajotte BCM5 wrong calibration?
231611 05/04/11 07:38 cdaq Run 11853: LH2 production at 165 uA, IHWP IN
231610 05/04/11 07:31 Korkmaz Compton dipole trip
231609 05/04/11 07:20 Korkmaz Moller magnet trip
231608 05/04/11 07:14 L.Lee QTOR reset and back up
231606 05/04/11 07:08 cdaq End of Run 11852:
231605 05/04/11 06:54 qwanalysis Analysis: Run 11852 - Plots and Summary Table for 100k Events.
231604 05/04/11 06:41 cdaq Run 11852: LH2 production at 165 uA, IHWP IN
231603 05/04/11 06:28 Korkmaz GT an HV plots
231602 05/04/11 05:49 qwanalysis Analysis: Run 11851 - Plots and Summary Table for 100k Events.
231601 05/04/11 05:48 jhlee mark this run as "not to be analyzed"
231600 05/04/11 05:43 jhlee DAQ is working again
231599 05/04/11 05:34 cdaq Run 11851: LH2 production at 165 uA, IHWP IN
231598 05/04/11 05:26 Korkmaz CODA problems
231597 05/04/11 05:25 cdaq End of Run 11850:
231596 05/04/11 05:25 cdaq Run 11850: DAQ test run
231595 05/04/11 04:40 cdaq End of Run 11848:
231594 05/04/11 03:50 qwanalysis Analysis: Run 11848 - Plots and Summary Table for 100k Events.
231593 05/04/11 03:36 cdaq Run 11848: LH2 production at 165 uA, IHWP IN
231592 05/04/11 03:31 cdaq End of Run 11847:
231591 05/04/11 03:00 qwanalysis Analysis: Run 11846 - Plots and Summary Table for 100k Events.
231590 05/04/11 02:59 cdaq Run 11847: LH2 production at 165 uA, IHWP IN
231589 05/04/11 02:57 cdaq End of Run 11846:
231588 05/04/11 02:49 cdaq Run 11846: LH2 production at 165 uA, IHWP IN
231587 05/04/11 02:33 Korkmaz QTOR PS reset locally
231586 05/04/11 02:31 Korkmaz CODA crash
231585 05/04/11 02:15 Korkmaz QTOR crash
231584 05/04/11 01:19 qwanalysis Analysis: Run 11845 - Plots and Summary Table for 100k Events.
231583 05/04/11 01:09 qwanalysis Analysis: Run 11844 - Plots and Summary Table for 100k Events.
231582 05/04/11 01:08 cdaq Run 11845: LH2 production at 165 uA, IHWP IN
231581 05/04/11 01:07 cdaq End of Run 11844:
231580 05/04/11 01:05 Korkmaz run 11843 no good
231579 05/04/11 00:59 cdaq Run 11844: LH2 production at 165 uA, IHWP IN
231578 05/04/11 00:56 cdaq End of Run 11843:
231577 05/04/11 00:52 L.Lee Target: Target GUI and strip charts screenshots with beam at 165 uA
231576 05/04/11 00:47 Korkmaz Beam is back, IHWP is IN
231575 05/04/11 00:46 cdaq Run 11843: LH2 production at 165 uA, IHWP IN
231574 05/04/11 00:06 L.Lee Target: Target GUI and strip charts screenshots at start of owl shift
231573 05/04/11 00:02 cdaq Beam Time Accounting
231572 05/04/11 00:01 Spayde Shift Summary: 05/03/2011 Swing Shift Summary
Tuesday
231571 05/03/11 23:15 Spayde Beam: Beam Gone for Awhile
231570 05/03/11 23:14 cdaq End of Run 11842:
231569 05/03/11 22:58 Spayde Checklist Screenshots
231568 05/03/11 22:52 hamlet Beam: Beam quality is not good
231567 05/03/11 22:29 qwanalysis Analysis: Run 11842 - Plots and Summary Table for 100k Events.
231566 05/03/11 22:19 cdaq Run 11842: LH2 production at 165 uA, IHWP OUT
231565 05/03/11 22:18 cdaq End of Run 11841:
231564 05/03/11 22:04 saw Tunsten plug water heating
231563 05/03/11 21:40 qwanalysis Analysis: Run 11841 - Plots and Summary Table for 100k Events.
231562 05/03/11 21:34 Spayde Compton: Compton DAQ Restarted
231561 05/03/11 21:32 cdaq Compton End of Run 21909 (standard):
231560 05/03/11 21:30 cdaq Compton Run 21909 (standard): DAQ Test
231559 05/03/11 21:25 Spayde Compton: Photon Detector HV Turned Off
231558 05/03/11 21:18 cdaq Run 11841: LH2 production at 165 uA, IHWP OUT
231557 05/03/11 21:16 cdaq End of Run 11840:
231556 05/03/11 21:16 rob late entry: templeton + wilbur signal cables now pass through event-mode amplifiers
231555 05/03/11 21:16 qwanalysis Analysis: Run 11840 - Plots and Summary Table for 100k Events.
231554 05/03/11 21:15 gaskell Compton: might as well leave photon detector off
231553 05/03/11 21:09 Spayde Halo Looks Good. Compton HVs turned on.
231552 05/03/11 21:03 smithg (MANY) other cables need to be inspected
231551 05/03/11 21:02 cdaq Run 11840: LH2 production at 170 uA, IHWP OUT
231550 05/03/11 21:02 cdaq Compton End of Run 21908 (standard):
231549 05/03/11 21:00 cdaq Compton Run 21908 (standard): DAQ Test
231548 05/03/11 20:55 gaskell Compton: laser off, shutter closed
231547 05/03/11 20:42 Spayde Right Dump Ion Chamber Behavior
231546 05/03/11 20:38 Spayde Beam: Beam Going Away For Awhile
231545 05/03/11 20:29 Spayde Turned Off Compton HV
231544 05/03/11 20:28 cdaq End of Run 11839:
231543 05/03/11 20:26 wdconinc Compton: Enabled db for data mover and happy dealer again
231542 05/03/11 20:23 hamlet Target: Target GUI and strip charts screenshots at the beam current 170 uA
231541 05/03/11 20:22 cdaq Run 11839: LH2 production at 170 uA, IHWP OUT
231540 05/03/11 20:21 cdaq End of Run 11838:
231539 05/03/11 20:15 Mahoney comments of ion chambers
231538 05/03/11 20:10 cdaq Run 11838: Checkout Run at 170 uA, IHWP OUT
231537 05/03/11 20:09 Spayde Go for 170 uA
231536 05/03/11 19:54 Spayde MCC Commissioning Dump Ion Chamber
231535 05/03/11 19:32 hamlet QTOR: Changed QTOR MPS current diff yelow high limmit from 1.5 to 2.0 A
231534 05/03/11 19:16 cdaq Compton End of Run 21907 (standard):
231533 05/03/11 19:14 Spayde Ramping Up QTOR
231532 05/03/11 18:52 cdaq Compton Run 21907 (standard): test run
231531 05/03/11 18:10 pking Changed data tracker reaper to mark new runs as analyzable
231530 05/03/11 18:06 smithg Target: shut off 4K pump bypass
231529 05/03/11 18:05 kenyon Test Complete
231528 05/03/11 18:02 pking The cdaql6 MySQL server is back up and available; restarting DAQ and autoanalyzer processes
231527 05/03/11 17:57 cdaq End of Run 11837:
231526 05/03/11 17:44 cdaq Run 11837: DAQ Test
231525 05/03/11 16:41 covrig Target: pid temperature regulation
231524 05/03/11 16:15 saw Epics variable names for Tunsten water temps
231523 05/03/11 16:07 buddhini Injector spot move done today during beam studies.
231522 05/03/11 15:59 buddhini Shift Summary: Day shift
231521 05/03/11 15:57 buddhini HV controls and general tools
231520 05/03/11 15:57 gaskell Compton: noise in laser lock?
231519 05/03/11 15:55 cdaq Beam Time Accounting
231518 05/03/11 15:07 beaufait thermal couples on tungston plug
231517 05/03/11 14:56 Jiawei Target: Dummy window return temperature alarm
231516 05/03/11 14:46 gaskell Compton: retracted electron detector
231515 05/03/11 13:18 kenyon Diffuser chiller status
231514 05/03/11 12:54 buddhini Andy and RADCON went in to the hall and after the check they left.
231513 05/03/11 11:19 Jiawei The result of the target boiling study by varying the pump speed and raster
231512 05/03/11 10:37 buddhini Late entry: Killed CODA in preperation for Pauls work on the database.
231511 05/03/11 10:36 buddhini Events with large charge asymmetries in slug 122-123
231510 05/03/11 10:35 buddhini Ramping down QTOR to zero. Will power it off after wards.
231509 05/03/11 10:08 rob refused entry to hall
231508 05/03/11 09:50 pking Preparing to halt the cdaql6 MySQL server; Talk to Paul before running the DAQ
231507 05/03/11 09:35 pking Stopped the data tracker "reaper" process on cdaql4
231506 05/03/11 09:18 buddhini Hall in controlled access. MCC doing beam studies.
231505 05/03/11 09:12 Jiawei reset the QWIOC4 to fix the halo rate epic_scaler displayer
231504 05/03/11 09:00 jhlee stop the autoanalyzers on cdaql5.
231503 05/03/11 08:06 cdaq Beam Time Accounting
231502 05/03/11 08:00 Korkmaz Shift Summary: Owl shift summary
231501 05/03/11 07:21 benesch Beam: elog entry about ion chamber degradation
231500 05/03/11 06:47 cdaq End of Run 11836:
231499 05/03/11 06:47 Korkmaz Right dump chamber is dead -- no beam
231498 05/03/11 06:47 cdaq Compton End of Run 21906 (standard):
231497 05/03/11 06:42 qwanalysis Analysis: Run 11836 - Plots and Summary Table for 100k Events.
231496 05/03/11 06:29 cdaq Run 11836: LH2 production at 133 uA, IHWP OUT
231495 05/03/11 06:27 cdaq End of Run 11835:
231494 05/03/11 06:23 Korkmaz beam back (for now) and more insight into the diffuser problem
231493 05/03/11 06:13 cdaq Compton Run 21906 (standard): Y=0.74mm {;} All eDet planes @500V
231492 05/03/11 06:11 cdaq Compton End of Run 21905 (standard):
231491 05/03/11 06:07 Korkmaz Beam off and the "diffuser"
231490 05/03/11 05:39 qwanalysis Analysis: Run 11835 - Plots and Summary Table for 100k Events.
231489 05/03/11 05:35 L.Lee Halo rates not reading out on epics_scaler.adl
231488 05/03/11 05:29 cdaq Compton Run 21905 (standard): Y=0.74mm {;} eDet HV Scan p1=p2=p3=300V
231487 05/03/11 05:22 cdaq Compton End of Run 21904 (standard):
231486 05/03/11 05:20 cdaq Run 11835: LH2 production at 140 uA, IHWP OUT
231485 05/03/11 05:19 cdaq End of Run 11834:
231484 05/03/11 04:30 qwanalysis Analysis: Run 11834 - Plots and Summary Table for 100k Events.
231483 05/03/11 04:20 cdaq Run 11834: LH2 production at 148 uA, IHWP OUT
231482 05/03/11 04:19 wdconinc Compton: Data move to tape disabled
231481 05/03/11 04:17 cdaq End of Run 11833:
231480 05/03/11 04:07 cdaq Compton Run 21904 (standard): Y=0.79mm {;} eDet HV Scan p1=p2=p3=300V
231479 05/03/11 04:06 cdaq Compton End of Run 21903 (standard):
231478 05/03/11 03:58 Korkmaz GT and HV plots
231477 05/03/11 03:30 qwanalysis Analysis: Run 11833 - Plots and Summary Table for 100k Events.
231476 05/03/11 03:13 cdaq Run 11833: LH2 production at 160 uA, IHWP OUT
231475 05/03/11 03:12 cdaq End of Run 11832:
231474 05/03/11 03:12 Korkmaz beam current
231473 05/03/11 03:05 cdaq Compton Run 21903 (standard): Y=0.79mm {;} eDet HV Scan p1=p2=p3=400V
231472 05/03/11 03:05 cdaq Compton End of Run 21902 (standard):
231471 05/03/11 02:45 qwanalysis Analysis: Run 11832 - Plots and Summary Table for 100k Events.
231470 05/03/11 02:16 Korkmaz CODA crash
231469 05/03/11 02:11 cdaq Run 11832: LH2 production at 170 uA, IHWP OUT
231468 05/03/11 02:02 cdaq Run 11831: LH2 production at 170 uA, IHWP OUT
231467 05/03/11 02:01 cdaq End of Run 11830:
231466 05/03/11 01:59 cdaq Compton Run 21902 (standard): Y=0.79mm {;} eDet HV Scan {p1=p2=p3=500V}
231465 05/03/11 01:58 cdaq Compton End of Run 21901 (standard):
231464 05/03/11 01:15 qwanalysis Analysis: Run 11830 - Plots and Summary Table for 100k Events.
231463 05/03/11 01:12 Korkmaz gun wafer
231462 05/03/11 01:10 L.Lee Target: Target GUI and strip charts screenshots (again) with beam at 170 uA
231461 05/03/11 01:02 narayan Compton: eDet plane-1 HV was -500V for this run
231460 05/03/11 01:01 cdaq Run 11830: LH2 production at 170 uA, IHWP OUT
231459 05/03/11 00:58 L.Lee Target: Target GUI and strip charts screenshots at start of owl shift
231458 05/03/11 00:54 cdaq Compton Run 21901 (standard): Y=0.79mm {;} eDet HV Scan {p1=425V, p2=p3=364V}
231457 05/03/11 00:52 Korkmaz QTOR PS reset locally
231456 05/03/11 00:27 pking Analysis: Clarification: the first100k analysis should still happen for the runs tonight
231455 05/03/11 00:24 cdaq End of Run 11829:
231454 05/03/11 00:23 cdaq Run 11829: DAQ Test Run
231453 05/03/11 00:20 pking Run 11828 and later runs will be marked "Not to be analyzed" for tonight.
231452 05/03/11 00:09 cdaq Compton End of Run 21900 (standard):
231451 05/03/11 00:08 cdaq Beam Time Accounting
231450 05/03/11 00:08 Spayde Shift Summary: 05/02/2011 Swing Shift Summary
Monday
231449 05/02/11 23:55 Spayde QTOR Failed to Ramp Up All the Way
231448 05/02/11 23:41 cdaq Compton Run 21900 (standard): Y=0.79mm {;} eDet HV Scan {p1=500V, p2=p3=364V}
231447 05/02/11 23:41 Spayde QTOR Crash
231446 05/02/11 23:40 cdaq End of Run 11828:
231445 05/02/11 23:38 cdaq Compton End of Run 21899 (standard):
231444 05/02/11 23:37 manos Compton: HV gui won't stop beeping
231443 05/02/11 23:30 Spayde Changes to Dump Ion Chamber Trip Levels
231442 05/02/11 22:48 qwanalysis Analysis: Run 11828 - Plots and Summary Table for 100k Events.
231441 05/02/11 22:38 cdaq Compton Run 21899 (standard): Y=0.79mm {;} eDet HV Scan {p1=425V, p2=p3=364V}
231440 05/02/11 22:37 cdaq Run 11828: LH2 production at 175 uA, IHWP OUT
231439 05/02/11 22:37 cdaq Compton End of Run 21898 (standard):
231438 05/02/11 22:37 cdaq End of Run 11827:
231437 05/02/11 21:47 qwanalysis Analysis: Run 11827 - Plots and Summary Table for 100k Events.
231436 05/02/11 21:37 cdaq Compton Run 21898 (standard): Y=0.79mm {;} eDet HV Scan p1=250V; p2=p3=364V
231435 05/02/11 21:32 cdaq Compton End of Run 21897 (standard):
231434 05/02/11 21:31 cdaq Run 11827: LH2 production at 175 uA, IHWP OUT
231433 05/02/11 21:30 cdaq End of Run 11826:
231432 05/02/11 21:10 narayan Target: target stable at 175 uA
231431 05/02/11 21:04 narayan Compton: IOCHC10 went unresponsive
231430 05/02/11 20:47 gaskell Moller LHE level ok
231429 05/02/11 20:46 gaskell Moller collimators
231428 05/02/11 20:42 qwanalysis Analysis: Run 11826 - Plots and Summary Table for 100k Events.
231427 05/02/11 20:35 Spayde Beam: Raising Beam Current to 175 uA
231426 05/02/11 20:31 cdaq Compton Run 21897 (standard): eDet HV {Scan;} Y=0.79mm {;}
231425 05/02/11 20:30 cdaq Compton End of Run 21896 (standard):
231424 05/02/11 20:30 cdaq Run 11826: LH2 production at 175 uA, IHWP OUT
231423 05/02/11 20:29 cdaq End of Run 11825:
231422 05/02/11 20:23 Spayde Shift Checklist Snapshots
231421 05/02/11 20:05 qwanalysis Analysis: Run 11825 - Plots and Summary Table for 100k Events.
231420 05/02/11 19:55 cdaq Compton Run 21896 (standard): eDet HV {Scan;} Y=0.79mm {;}
231419 05/02/11 19:54 cdaq Run 11825: LH2 production at 170 uA, IHWP OUT
231418 05/02/11 19:52 Spayde Completed BCM Calibration. Going Back to Production Running.
231417 05/02/11 19:51 cdaq End of Run 11824:
231416 05/02/11 19:39 cdaq Compton End of Run 21895 (standard):
231415 05/02/11 19:15 narayan Compton: Electron detector moved to 'beam' position
231414 05/02/11 19:14 qwanalysis Analysis: Run 11823 - Plots and Summary Table for 100k Events.
231413 05/02/11 19:12 dunne Target: High Power PID issue
231412 05/02/11 19:11 dunne Target: High Power PID issue
231411 05/02/11 19:10 Spayde Completed Target Boiling Studies
231410 05/02/11 19:09 cdaq Run 11824: BCM Calibration
231409 05/02/11 19:08 cdaq End of Run 11823:
231408 05/02/11 19:05 cdaq Compton Run 21895 (standard): eDet HV Scan; Y=0.79mm {;}
231407 05/02/11 19:03 qwanalysis Analysis: Run 11822 - Plots and Summary Table for 100k Events.
231406 05/02/11 19:03 cdaq Run 11823: LH2 production at 170 uA, IHWP OUT
231405 05/02/11 19:02 cdaq Compton End of Run 21894 (standard):
231404 05/02/11 18:57 SMITHG Target: striptools of the 3x5 & 5x3 / pump speed scans
231403 05/02/11 18:54 cdaq End of Run 11822:
231402 05/02/11 18:53 qwanalysis Analysis: Run 11821 - Plots and Summary Table for 100k Events.
231401 05/02/11 18:49 cdaq Run 11822: Target Boiling: 170 uA, 4x4 Raster, 12.0 Hz Pump Speed
231400 05/02/11 18:48 cdaq End of Run 11821:
231399 05/02/11 18:47 qwanalysis Analysis: Run 11820 - Plots and Summary Table for 100k Events.
231398 05/02/11 18:43 cdaq Run 11821: Target Boiling: 170 uA, 5x3 Raster, 12.0 Hz Pump Speed
231397 05/02/11 18:42 cdaq End of Run 11820:
231396 05/02/11 18:38 qwanalysis Analysis: Run 11819 - Plots and Summary Table for 100k Events.
231395 05/02/11 18:37 cdaq Run 11820: Target Boiling: 170 uA, 3x5 Raster, 12.0 Hz Pump Speed
231394 05/02/11 18:35 cdaq End of Run 11819:
231393 05/02/11 18:33 qwanalysis Analysis: Run 11818 - Plots and Summary Table for 100k Events.
231392 05/02/11 18:32 manos Compton: Beam profile scan
231391 05/02/11 18:28 cdaq Run 11819: Target Boiling: 170 uA, 3x5 Raster, 25.2 Hz Pump Speed
231390 05/02/11 18:27 cdaq End of Run 11818:
231389 05/02/11 18:25 qwanalysis Analysis: Run 11817 - Plots and Summary Table for 100k Events.
231388 05/02/11 18:22 cdaq Compton Run 21894 (standard): HV scan, phDet HV: 1800 Y=0.79mm ; edet in Garage
231387 05/02/11 18:21 cdaq Run 11818: Target Boiling: 170 uA, 5x3 Raster, 25.2 Hz Pump Speed
231386 05/02/11 18:20 cdaq End of Run 11817:
231385 05/02/11 18:19 cdaq Compton End of Run 21893 (standard):
231384 05/02/11 18:18 qwanalysis Analysis: Run 11816 - Plots and Summary Table for 100k Events.
231383 05/02/11 18:15 qwanalysis Analysis: Run 11815 - Plots and Summary Table for 100k Events.
231382 05/02/11 18:14 cdaq Run 11817: Target Boiling: 170 uA, 4x4 Raster, 25.2 Hz Pump Speed
231381 05/02/11 18:13 cdaq End of Run 11816:
231380 05/02/11 18:08 narayan Target: lowered the LO alarm limit on h2 pump head differential pressure
231379 05/02/11 18:06 cdaq Run 11816: Target Boiling: 170 uA, 4x4 Raster, 15.3 Hz Pump Speed
231378 05/02/11 18:05 cdaq End of Run 11815:
231377 05/02/11 18:03 qwanalysis Analysis: Run 11814 - Plots and Summary Table for 100k Events.
231376 05/02/11 17:59 cdaq Run 11815: Target Boiling: 170 uA, 5x3 Raster, 15.3 Hz Pump Speed
231375 05/02/11 17:58 cdaq End of Run 11814:
231374 05/02/11 17:55 qwanalysis Analysis: Run 11813 - Plots and Summary Table for 100k Events.
231373 05/02/11 17:52 cdaq Run 11814: Target Boiling: 170 uA, 3x5 Raster, 15.3 Hz Pump Speed
231372 05/02/11 17:50 cdaq End of Run 11813:
231371 05/02/11 17:47 qwanalysis Analysis: Run 11812 - Plots and Summary Table for 100k Events.
231370 05/02/11 17:45 cdaq Run 11813: Target Boiling: 170 uA, 3x5 Raster, 18.6 Hz Pump Speed
231369 05/02/11 17:43 cdaq End of Run 11812:
231368 05/02/11 17:39 qwanalysis Analysis: Run 11811 - Plots and Summary Table for 100k Events.
231367 05/02/11 17:36 cdaq Run 11812: Target Boiling: 170 uA, 5x3 Raster, 18.6 Hz Pump Speed
231366 05/02/11 17:35 cdaq End of Run 11811:
231365 05/02/11 17:32 qwanalysis Analysis: Run 11810 - Plots and Summary Table for 100k Events.
231364 05/02/11 17:28 cdaq Run 11811: Target Boiling: 170 uA, 4x4 Raster, 18.6 Hz Pump Speed
231363 05/02/11 17:28 cdaq End of Run 11810:
231362 05/02/11 17:26 rajotte Target beam parameter added to the last 24 runs plots
231361 05/02/11 17:24 qwanalysis Analysis: Run 11809 - Plots and Summary Table for 100k Events.
231360 05/02/11 17:22 cdaq Run 11810: Target Boiling: 170 uA, 4x4 Raster, 21.9 Hz Pump Speed
231359 05/02/11 17:21 cdaq End of Run 11809:
231358 05/02/11 17:20 qwanalysis Analysis: Run 11806 - Plots and Summary Table for 100k Events.
231357 05/02/11 17:16 qwanalysis Analysis: Run 11808 - Plots and Summary Table for 100k Events.
231356 05/02/11 17:14 cdaq Run 11809: Target Boiling: 170 uA, 5x3 Raster, 21.9 Hz Pump Speed
231355 05/02/11 17:13 cdaq End of Run 11808:
231354 05/02/11 17:09 cdaq Compton Run 21893 (standard): HV scan, phDet HV: 1800 ; edet in Garage
231353 05/02/11 17:08 qwanalysis Analysis: Run 11807 - Plots and Summary Table for 100k Events.
231352 05/02/11 17:06 cdaq Run 11808: Target Boiling: 170 uA, 3x5 Raster, 21.9 Hz Pump Speed
231351 05/02/11 17:05 cdaq End of Run 11807:
231350 05/02/11 16:58 cdaq Run 11807: Target Boiling: 170 uA, 3x5 Raster, 28.5 Hz Pump Speed
231349 05/02/11 16:57 cdaq End of Run 11806:
231348 05/02/11 16:52 qwanalysis Analysis: Run 11805 - Plots and Summary Table for 100k Events.
231347 05/02/11 16:48 cdaq Run 11806: Target Boiling: 170 uA, 5x3 Raster, 28.5 Hz Pump Speed
231346 05/02/11 16:47 cdaq End of Run 11805:
231345 05/02/11 16:45 Spayde Beam: Back to 170 uA. Starting Target Boiling Studies and BCM Calibration.
231344 05/02/11 16:43 cdaq Run 11805: Target Boiling: 170 uA, 4x4 Raster, 28.5 Hz Pump Speed
231343 05/02/11 16:32 Spayde Beam: MCC Sending Tune Beam to Hall
231342 05/02/11 16:03 cdaq Beam Time Accounting
231341 05/02/11 15:39 manos Beam: X-position differences at the target
231340 05/02/11 15:37 M Jones Shift Summary: Day Shift summary
231339 05/02/11 15:09 M Jones HV and GT
231338 05/02/11 15:08 pking The cdaql6 MySQL server will be taken down about 10:00 tomorrow
231337 05/02/11 14:33 M Jones Finished with Moller. Waiting for beam
231336 05/02/11 14:15 magee/rakith Moller collimators moved
231335 05/02/11 14:14 Solvignon Solenoid Cryo at 0.00%. Is it real ?
231334 05/02/11 12:30 brads Disk space on /group/qweak/ and /net/cdaqfs/scratch/ running out -- PLEASE CLEAN UP OLD FILES
231333 05/02/11 12:23 M Jones Escorted access to reset Moller collimator power supply
231332 05/02/11 12:10 birchall Target: Moved LH2 target into beam position
231331 05/02/11 12:09 M Jones Qweak HV back ON and Beam Mod back ON
231330 05/02/11 12:07 rakithab/mag Analysis: Moller Polarization Results
231329 05/02/11 12:04 magee Compton electron detector still OUT
231328 05/02/11 11:51 magee BCM2 to gain setting 2
231327 05/02/11 11:48 magee Moller measurement concluded - backing out
231326 05/02/11 11:35 cdaq Moller Run 1105: IHWP=OUT Production,
231325 05/02/11 11:27 cdaq Moller Run 1104: IHWP=OUT Production,
231324 05/02/11 11:19 rakithab IHWP is OUT now
231323 05/02/11 11:19 cdaq Moller Run 1103: IHWP=OUT Production,
231322 05/02/11 11:08 cdaq Moller Run 1102: IHWP=IN Production,
231321 05/02/11 11:06 cdaq Moller Run 1101: IHWP=IN Production,
231320 05/02/11 10:58 cdaq Moller Run 1100: IHWP=IN Production,
231319 05/02/11 10:56 cdaq Moller Run 1099: IHWP=IN Production,
231318 05/02/11 10:55 cdaq Moller Run 1098: IHWP=IN Production,
231317 05/02/11 10:52 cdaq Moller Run 1097: IHWP=IN Production,
231316 05/02/11 10:44 cdaq Moller Run 1096: IHWP=IN Production,
231315 05/02/11 10:43 cdaq Moller Run 1095: IHWP=IN Production,
231314 05/02/11 10:38 rakithab Moller BPM positions
231313 05/02/11 10:34 cdaq Moller Run 1094: IHWP=IN Production,
231312 05/02/11 10:32 cdaq Moller Run 1093: IHWP=IN Production,
231311 05/02/11 10:27 cdaq Moller Run 1092: IHWP=IN Production,
231310 05/02/11 10:19 cdaq Moller Run 1091: IHWP=IN Production,
231309 05/02/11 10:13 cdaq Moller Run 1090: IHWP=IN Production,
231308 05/02/11 09:03 cdaq Moller Run 1089: Test Moller DAQ
231307 05/02/11 09:02 Solvignon Rebooted Moller crate
231306 05/02/11 08:56 cdaq Moller Run 1088: Test Moller DAQ
231305 05/02/11 08:42 birchall Target: Target moved to out for beam for Moller measurement
231304 05/02/11 08:42 cdaq End of Run 11804:
231303 05/02/11 08:41 Solvignon Moller setup
231302 05/02/11 08:37 M Jones Turn off off HV and beam modulation for Moller setup
231301 05/02/11 08:36 cdaq Compton End of Run 21892 (standard):
231300 05/02/11 08:35 Solvignon Beam parameters prior to Moller measurement
231299 05/02/11 08:06 Korkmaz Shift Summary: Owl shift summary -- please ignore entry 231298 (submitted by mistake)
231298 05/02/11 07:50 Shift Summary: Owl shift summary
231297 05/02/11 07:41 qwanalysis Analysis: Run 11804 - Plots and Summary Table for 100k Events.
231296 05/02/11 07:30 cdaq Compton Run 21892 (standard): HV scan, phDet HV: {1750;}
231295 05/02/11 07:30 cdaq Compton End of Run 21891 (standard):
231294 05/02/11 07:29 cdaq Run 11804: LH2 production at 170 uA, IHWP IN
231293 05/02/11 07:28 cdaq End of Run 11803:
231292 05/02/11 07:27 L.Lee Target: Ask MCC to lower ramp rate due to HiPowerHtr alarms on beam recovery
231291 05/02/11 07:11 cdaq Beam Time Accounting
231290 05/02/11 06:43 qwanalysis Analysis: Run 11803 - Plots and Summary Table for 100k Events.
231289 05/02/11 06:30 Korkmaz Beam is back
231288 05/02/11 06:29 cdaq Compton Run 21891 (standard): HV scan, phDet HV: {1750;}
231287 05/02/11 06:28 cdaq Run 11803: LH2 production at 170 uA, IHWP IN
231286 05/02/11 06:20 Korkmaz beam status
231285 05/02/11 05:06 Korkmaz Beam will be off for a while
231284 05/02/11 05:05 cdaq Compton End of Run 21890 (standard):
231283 05/02/11 05:02 cdaq End of Run 11802:
231282 05/02/11 04:54 cdaq Compton Run 21890 (standard): HV scan, phDet HV: 1750; v1495 firmware rev 0x3219 loaded
231281 05/02/11 04:41 cdaq Compton End of Run 21889 (standard):
231280 05/02/11 04:17 qwanalysis Analysis: Run 11802 - Plots and Summary Table for 100k Events.
231279 05/02/11 04:14 Korkmaz GT and HV
231278 05/02/11 03:59 cdaq Run 11802: LH2 production at 170 uA, IHWP IN
231277 05/02/11 03:58 cdaq End of Run 11801:
231276 05/02/11 03:20 cdaq Compton Run 21889 (standard): HV scan, phDet HV: 1750
231275 05/02/11 03:11 cdaq Compton End of Run 21888 (standard):
231274 05/02/11 03:09 qwanalysis Analysis: Run 11801 - Plots and Summary Table for 100k Events.
231273 05/02/11 02:55 cdaq Run 11801: LH2 production at 170 uA, IHWP IN
231272 05/02/11 02:54 cdaq End of Run 11800:
231271 05/02/11 02:19 qwanalysis Analysis: Run 11800 - Plots and Summary Table for 100k Events.
231270 05/02/11 02:02 cdaq Compton Run 21888 (standard): HV scan, phDet HV: 1750 {;} rev 3219, pl_delay = 6
231269 05/02/11 01:54 cdaq Compton End of Run 21887 (standard):
231268 05/02/11 01:54 cdaq Run 11800: LH2 production at 170 uA, IHWP IN
231267 05/02/11 01:53 cdaq End of Run 11799:
231266 05/02/11 01:11 qwanalysis Analysis: Run 11799 - Plots and Summary Table for 100k Events.
231265 05/02/11 00:54 cdaq Compton Run 21887 (standard): HV scan, phDet HV: 1850 {;} rev 3219
231264 05/02/11 00:54 Korkmaz FlipPCValues just before run 11799
231263 05/02/11 00:52 cdaq Run 11799: LH2 production at 170 uA, IHWP IN
231262 05/02/11 00:50 cdaq End of Run 11798:
231261 05/02/11 00:44 cdaq Compton End of Run 21886 (standard):
231260 05/02/11 00:15 L.Lee Target: Target GUI and strip charts screenshots at start of owl shift
231259 05/02/11 00:03 cdaq Beam Time Accounting
231258 05/02/11 00:03 narayan Target: beam current increased to 175 uA
231257 05/02/11 00:02 Spayde Shift Summary: Swing Shift Summary 05/01/2011
Sunday
231256 05/01/11 23:58 jhlee bcm1 and fastfeedback status from 22:00
231255 05/01/11 23:57 qwanalysis Analysis: Run 11798 - Plots and Summary Table for 100k Events.
231254 05/01/11 23:49 manos Compton: Anode current at 175uA and 1850V still safe
231253 05/01/11 23:45 cdaq Compton Run 21886 (standard): HV scan, phDet HV: 1850 {;} rev 3219
231252 05/01/11 23:43 Spayde Beam: Raised Beam Current to 175 uA
231251 05/01/11 23:42 cdaq Run 11798: LH2 production at 175 uA
231250 05/01/11 23:42 cdaq Compton End of Run 21885 (standard):
231249 05/01/11 23:42 cdaq End of Run 11797:
231248 05/01/11 23:36 jhlee re:DAQ Crash at End of Run 11796
231247 05/01/11 23:25 manos Large variation in MS interception when rates changed.
231246 05/01/11 23:23 Spayde Beam: Raised Beam Current to 170 uA
231245 05/01/11 23:11 Spayde Beam: Halo and Compton Scintillator Rates Degraded/Fast Feedback Values Gone Wonky
231244 05/01/11 22:54 qwanalysis Analysis: Run 11797 - Plots and Summary Table for 100k Events.
231243 05/01/11 22:52 Spayde DAQ Crash at End of Run 11796
231242 05/01/11 22:51 cdaq Compton Run 21885 (standard): HV scan, phDet HV: 1800 ; rev 3219
231241 05/01/11 22:43 cdaq Compton End of Run 21884 (standard):
231240 05/01/11 22:41 cdaq Run 11797: LH2 production at 165 uA
231239 05/01/11 21:45 manos Compton: HV scan: Photon detector HV 1850V
231238 05/01/11 21:38 cdaq Compton Run 21884 (standard): HV scan, eDet HV all plane = 364, phDet HV: 1850
231237 05/01/11 21:37 qwanalysis Analysis: Run 11796 - Plots and Summary Table for 100k Events.
231236 05/01/11 21:35 cdaq Compton End of Run 21883 (standard):
231235 05/01/11 21:27 cdaq Run 11796: LH2 production at 165 uA
231234 05/01/11 21:26 cdaq End of Run 11795:
231233 05/01/11 21:12 Spayde General Tools/HV GUI Screenshot
231232 05/01/11 20:40 qwanalysis Analysis: Run 11795 - Plots and Summary Table for 100k Events.
231231 05/01/11 20:27 Spayde Beam: Beam is Back
231230 05/01/11 20:26 cdaq Compton Run 21883 (standard): HV scan, eDet HV all plane = 364, phDet HV: 1800
231229 05/01/11 20:26 cdaq Compton End of Run 21882 (standard):
231228 05/01/11 20:25 cdaq Run 11795: LH2 production at 165 uA
231227 05/01/11 20:03 Spayde Ramped QTOR to 8921 A
231226 05/01/11 19:57 cdaq End of Run 11794:
231225 05/01/11 19:55 Spayde Beam: Beam Down for 5 Minutes
231224 05/01/11 19:22 cdaq Compton Run 21882 (standard): HV scan, eDet HV all plane = 364, phDet HV: 1800
231223 05/01/11 19:20 cdaq Compton End of Run 21881 (standard):
231222 05/01/11 19:15 qwanalysis Analysis: Run 11794 - Plots and Summary Table for 100k Events.
231221 05/01/11 19:04 Spayde QTOR to 8966 A
231220 05/01/11 19:03 cdaq Run 11794: LH2 production at 165 uA with QTOR at 8966 A
231219 05/01/11 19:02 cdaq End of Run 11793:
231218 05/01/11 18:30 Spayde Good Conditions?
231217 05/01/11 18:15 qwanalysis Analysis: Run 11793 - Plots and Summary Table for 100k Events.
231216 05/01/11 18:12 cdaq Compton Run 21881 (standard): HV scan, eDet HV all plane = 364, phDet HV: 1800
231215 05/01/11 18:03 Spayde Beam: MCC Sending Beam Back
231214 05/01/11 18:02 cdaq Run 11793: LH2 production at 165 uA
231213 05/01/11 18:00 cdaq Compton End of Run 21880 (standard):
231212 05/01/11 17:59 cdaq End of Run 11792:
231211 05/01/11 17:58 Spayde Beam: MCC Taking Beam Away
231210 05/01/11 17:36 Spayde Beam: Beam at 140 uA for Diagnostics
231209 05/01/11 17:35 manos Compton: Vertical scan, HV back to 1800V, transmition loss related to orbit lock.
231208 05/01/11 17:28 qwanalysis Analysis: Run 11792 - Plots and Summary Table for 100k Events.
231207 05/01/11 17:22 cdaq Compton Run 21880 (standard): HV scan, eDet HV all plane = 364, phDet HV: 1800
231206 05/01/11 17:17 cdaq Run 11792: LH2 production at 165 uA
231205 05/01/11 17:16 cdaq End of Run 11791:
231204 05/01/11 16:58 Spayde Beam: Reduced Beam Current for Vertical Scan
231203 05/01/11 16:44 qwanalysis Analysis: Run 11791 - Plots and Summary Table for 100k Events.
231202 05/01/11 16:38 Spayde Beam: Vertical Scan in the Chicane
231201 05/01/11 16:30 cdaq Compton End of Run 21879 (standard):
231200 05/01/11 16:29 cdaq Run 11791: LH2 production at 165 uA
231199 05/01/11 16:28 cdaq End of Run 11790:
231198 05/01/11 16:02 cdaq Beam Time Accounting
231197 05/01/11 16:01 M Jones Shift Summary: Day Shift summary
231194 05/01/11 15:59 Pitt Target: End of day shift screenshot
231193 05/01/11 15:41 qwanalysis Analysis: Run 11790 - Plots and Summary Table for 100k Events.
231192 05/01/11 15:33 M Jones HV and GT screens
231191 05/01/11 15:30 gaskell Compton: flipper mount not moving
231190 05/01/11 15:26 cdaq Run 11790: LH2 production at 165 uA
231189 05/01/11 15:26 qwanalysis Analysis: Run 11789 - Plots and Summary Table for 100k Events.
231188 05/01/11 15:26 cdaq Compton Run 21879 (standard): HV scan, eDet HV all plane = 364
231187 05/01/11 15:25 cdaq End of Run 11789:
231186 05/01/11 15:25 cdaq Compton End of Run 21878 (standard):
231185 05/01/11 15:15 another EB4 crash at en of run
231184 05/01/11 15:13 M JOnes IHWP = OUT , FlipPCValues
231183 05/01/11 15:12 cdaq Run 11789: LH2 production at 165 uA
231182 05/01/11 15:09 cdaq Compton Run 21878 (standard): HV scan, eDet HV all plane = 364
231181 05/01/11 15:08 cdaq Compton End of Run 21877 (standard):
231180 05/01/11 15:08 narayan Compton: (late entry) During Run 21875, Scintillator rates came down to 40
231179 05/01/11 14:23 qwanalysis Analysis: Run 11788 - Plots and Summary Table for 100k Events.
231178 05/01/11 14:07 cdaq Run 11788: LH2 production at 165 uA
231177 05/01/11 14:07 cdaq Compton Run 21877 (standard): HV scan, eDet HV all plane = 364
231176 05/01/11 14:06 cdaq Compton End of Run 21876 (standard):
231175 05/01/11 14:06 cdaq End of Run 11787:
231174 05/01/11 13:11 qwanalysis Analysis: Run 11787 - Plots and Summary Table for 100k Events.
231173 05/01/11 12:54 cdaq Compton Run 21876 (standard): HV scan, eDet HV all plane = 364
231172 05/01/11 12:51 cdaq Run 11787: LH2 production at 165 uA
231171 05/01/11 12:51 cdaq Compton End of Run 21875 (standard):
231170 05/01/11 12:51 cdaq End of Run 11786:
231169 05/01/11 12:30 narayan Compton: Run 21869 - 21875 : incorrect eDet HV in Run comment
231168 05/01/11 12:28 Pitt Summary of recent halo and Compton scintillator rate improvements
231167 05/01/11 12:13 Benesch Beam: Yan Wang solved Compton background: Hall C laser phase
231166 05/01/11 11:52 qwanalysis Analysis: Run 11786 - Plots and Summary Table for 100k Events.
231165 05/01/11 11:45 qwanalysis Analysis: Run 11785 - Plots and Summary Table for 100k Events.
231164 05/01/11 11:43 M Jones During Run 11785 MCC improving injector optics by injector autosteer
231163 05/01/11 11:38 cdaq Compton Run 21875 (standard): 165 uA eDet and phDet HV scan
231162 05/01/11 11:37 cdaq Run 11786: LH2 production at 165 uA
231161 05/01/11 11:37 cdaq Compton End of Run 21874 (standard):
231160 05/01/11 11:37 cdaq End of Run 11785:
231159 05/01/11 11:33 cdaq Run 11785: LH2 production at 165 uA
231158 05/01/11 11:33 cdaq Compton Run 21874 (standard): 165 uA eDet and phDet HV scan
231157 05/01/11 11:32 cdaq Compton End of Run 21873 (standard):
231156 05/01/11 11:32 cdaq End of Run 11784:
231155 05/01/11 11:27 qwanalysis Analysis: Run 11784 - Plots and Summary Table for 100k Events.
231154 05/01/11 11:12 cdaq Compton Run 21873 (standard): 165 uA eDet and phDet HV scan
231153 05/01/11 11:12 cdaq Run 11784: LH2 production at 165 uA
231152 05/01/11 11:11 cdaq Compton End of Run 21872 (standard):
231151 05/01/11 11:11 cdaq End of Run 11783:
231150 05/01/11 11:03 PItt More on halo rates - no change observed Saturday when Hall A went to 120 uA
231149 05/01/11 10:59 Pitt Discrete change in halo rates was when Hall A turned back on
231148 05/01/11 10:34 qwanalysis Analysis: Run 11783 - Plots and Summary Table for 100k Events.
231147 05/01/11 10:29 Pitt Halo rates increasing
231146 05/01/11 10:13 qwanalysis Analysis: Run 11782 - Plots and Summary Table for 100k Events.
231145 05/01/11 10:12 cdaq Run 11783: LH2 production at 165 uA
231144 05/01/11 10:12 cdaq Compton Run 21872 (standard): 165 uA eDet and phDet HV scan
231143 05/01/11 10:11 cdaq Compton End of Run 21871 (standard):
231142 05/01/11 10:11 cdaq End of Run 11782:
231141 05/01/11 09:50 M Jones End of run is failing, restart CODA
231140 05/01/11 09:48 cdaq Run 11782: LH2 production at 165 uA
231139 05/01/11 09:47 cdaq Compton Run 21871 (standard): 165 uA eDet and phDet HV scan
231138 05/01/11 09:47 cdaq Compton End of Run 21870 (standard):
231137 05/01/11 09:08 qwanalysis Analysis: Run 11781 - Plots and Summary Table for 100k Events.
231136 05/01/11 08:52 qwanalysis Analysis: Run 11780 - Plots and Summary Table for 100k Events.
231135 05/01/11 08:42 cdaq Run 11781: LH2 production at 165 uA
231134 05/01/11 08:42 cdaq Compton Run 21870 (standard): 165 uA eDet and phDet HV scan
231133 05/01/11 08:38 M JOnes Restarted coda
231132 05/01/11 08:30 M JOnes Beam off for about 15min
231131 05/01/11 08:29 M JOnes Run 11780 was only prestarted at 4:30am. GO was done at 8:08
231130 05/01/11 08:26 cdaq Compton End of Run 21869 (standard):
231129 05/01/11 08:21 manos Owl shift summary
231128 05/01/11 08:05 cdaq Beam Time Accounting
231127 05/01/11 08:05 Pitt Target: Target screenshots - with pictures this time
231126 05/01/11 08:02 Pitt Target: Beginning of day shift screenshots
231125 05/01/11 05:34 manos Owl shift screenshots
231124 05/01/11 04:38 cdaq Compton Run 21869 (standard): 165 uA eDet and phDet HV scan
231123 05/01/11 04:29 manos Beam still down
231122 05/01/11 04:19 cdaq Run 11780: LH2 production at 165 uA
231121 05/01/11 03:59 manos Arc 5 tripped again. Down for some time.
231120 05/01/11 03:53 manos MCC still down, even though MCC called to tell us they solved the problem
231119 05/01/11 03:43 cdaq Compton End of Run 21868 (standard):
231118 05/01/11 03:31 manos Large Aq in this run
231117 05/01/11 03:29 cdaq End of Run 11779:
231116 05/01/11 03:28 manos Beam down again
231115 05/01/11 03:17 qwanalysis Analysis: Run 11779 - Plots and Summary Table for 100k Events.
231114 05/01/11 03:12 cdaq Compton Run 21868 (standard): HV scan, eDet HV all plane = 364
231113 05/01/11 03:06 cdaq Compton End of Run 21867 (standard):
231112 05/01/11 03:05 manos Beam back
231111 05/01/11 02:56 manos Beam down for a while
231110 05/01/11 02:39 cdaq Run 11778 Pedestal Data
231109 05/01/11 02:38 cdaq Run 11779: LH2 production at 165 uA
231108 05/01/11 02:38 cdaq End of Run 11778:
231107 05/01/11 02:37 cdaq Run 11778: pedestals
231106 05/01/11 02:36 cdaq End of Run 11777:
231105 05/01/11 01:54 qwanalysis Analysis: Run 11777 - Plots and Summary Table for 100k Events.
231104 05/01/11 01:53 manos FlipPCValues output
231103 05/01/11 01:39 cdaq Compton Run 21867 (standard): 165 uA eDet and phDet HV scan
231102 05/01/11 01:31 manos IHWP --> IN
231101 05/01/11 01:27 cdaq Compton End of Run 21866 (standard):
231100 05/01/11 01:26 cdaq Run 11777: LH2 production at 165 uA, transition run(if Aq unacceptable)
231099 05/01/11 01:24 cdaq End of Run 11776:
231098 05/01/11 00:43 Jiawei It seems that bcm2 caused the DD width increased
231097 05/01/11 00:41 qwanalysis Analysis: Run 11776 - Plots and Summary Table for 100k Events.
231096 05/01/11 00:29 cdaq Run 11776: LH2 production at 165 uA
231095 05/01/11 00:28 cdaq End of Run 11775:
231094 05/01/11 00:17 L.Lee Target: Target GUI and strip charts screen shots at start of owl shift.
231093 05/01/11 00:11 cdaq Compton Run 21866 (standard): 165 uA eDet and phDet HV scan
231092 05/01/11 00:03 cdaq Beam Time Accounting
231091 05/01/11 00:02 Spayde Shift Summary: Swing Shift Summary
231090 05/01/11 00:01 cdaq Compton End of Run 21865 (standard):
This file generated by /group/hallc/www/hallcweb/apps/logbooks/hclog/src/hclogscript version HC2.27
If you have any comments or problems, please contact:
Stephen A. Wood
saw@jlab.org
(757) 269-7367