Main INDEX, Monthly INDEX, ,
Make New Entry, Make Followup Entry (Advanced)

User name cdaq

Log entry time 23:17:52 on November 15, 2011

Entry number 238506

keyword=Run 13450: HDC test run

Experiment qweak

Run #13450 - /net/cdaq/scratch2/qweak/rawdata/track_noR1_13450.dat.0

HV used HV.2010-12-02-09:50:00.hvcHV.2010-12-02-09:50:00.hvc
PS1 16777215 16777215
PS2 16777215 16777215
PS3 16777215 16777215
PS4 16777215 16777215
PS5 0 0
PS6 65535 65535
PS7 65535 65535
PS8 65535 65535
Beam Energy (MeV) 1155.91155.9
Beam Current BCM1 (uA) -0.0691008-0.0691008
Beam Current BCM2 (uA) -0.00252428-0.00252428
Half Wave Plate OUTOUT
Raster (width) X mm 33
Raster (height) Y mm 33
Qweak Target UnknownUnknown
All pmts fine? ..
Number of sick pmts ..

High voltages {on;} see screenshot

Thresholds all at

H2: 7.0 V
H3: 8.0 V
H4: 11.5 V
H5: 7.0 V