------------------------------------------------------------------------ Run Number : 13953 End of Run Comment: Beam current reduced. ------------------------------------------------------------------------ ************ Qweak/HallC EPICS variables MPS Beam Current (uA) [IBC3H00CRCUR4 ]: 138.99 Hall C Beam Current BCM1 (uA) [ibcm1 ]: 138.252 Hall C Beam Current BCM2 (uA) [ibcm2 ]: 137.968 Hall C Beam Current BCM17 (uA) [ibcm3 ]: -45.9635 Hall C Beam Energy Set (MeV) [MBSY3C_energy ]: 1159.97 Hall C Beam Energy Read (MeV) [HALLC:p ]: 1157.44 Qweak Magnet Current (A) [qw:qt_mps_i_dcct]: 8900.1 Qweak Magnet Field (Gauss) [Q1HallP ]: -707.43 HalfWave Plate State [IGL1I00DI24_24M ]: IN Qweak Target [QWtgt_name ]: HYDROGEN-CELL Hall C fast feedback Set [FB_C:FB_On ]: On Hall C fast feedback Read [FB_C:status:ON ]: 0 Hall C energy lock [FB_C:use_RF ]: RF On Hall A energy lock [FB_A:use_RF ]: RF Off Raster X (width) (mm) [EHCFR_LIXWidth ]: 4 Raster Y (height) (mm) [EHCFR_LIYWidth ]: 4 ************ Injector EPICS variables Wien angle (Vertical) [VWienAngle ]: 89.9999 Wien Vertical BDL (Gcm) [MWF1I04.BDL ]: 2626.6 Wien HV Polarity [IGL1I00OD16_4 ]: POSITIVE Wien electrode Voltage [IGL1I00DAC6 ]: 0 Wien angle (Solenoids) [Phi_FG ]: 88.1719 Wien BDL (First Solenoid) (Gcm) [MFG1I04A.BDL ]: 978.6 Wien BDL (Second Solenoid) (Gcm) [MFG1I04B.BDL ]: 978.6 Wien angle (Horizontal) [HWienAngle ]: 0 Wien BDL (Gcm) [MWF0I02.BDL ]: -25 Wien HV Polarity (Horizontal) [IGL1I00OD16_9 ]: POSITIVE Wien electrode Voltage (Horizontal)[IGL1I00DAC5 ]: 0 Beam Half-wave plate Set(off=out) [IGL1I00OD16_16 ]: IN Beam Half-wave plate Read(off=out) [IGL1I00DI24_24M ]: IN Rotating waveplate [psub_pl_pos ]: 6479.1 Pockels Cell Voltages Positive [C1068_QDAC01 ]: 40551.2 Pockels Cell Voltages Negative [C1068_QDAC02 ]: 41878.8 Hall A IA Setpoints [C1068_QDAC03 ]: 32800 Hall A IA Setpoints [C1068_QDAC04 ]: 32800 Hall A IA Setpoints [C1068_QDAC05 ]: 32800 Hall A IA Setpoints [C1068_QDAC06 ]: 32800 Hall B IA Setpoints [C1068_QDAC07 ]: 32800 Hall B IA Setpoints [C1068_QDAC08 ]: 32800 Hall B IA Setpoints [C1068_QDAC09 ]: 32800 Hall B IA Setpoints [C1068_QDAC10 ]: 32800 Hall C IA Setpoints [C1068_QDAC11 ]: 33411 Hall C IA Setpoints [C1068_QDAC12 ]: 33411 Hall C IA Setpoints [C1068_QDAC13 ]: 33411 Hall C IA Setpoints [C1068_QDAC14 ]: 33411 Pockels Cell ON/OFF [IGL1I00OD16_8 ]: ON Pockels Cell X Stage [cdipc_xpos ]: 0.03135 Pockels Cell Y Stage [cdipc_ypos ]: 0.04685 Wager X Stage [psub_cx_pos ]: 10250 Wager Y Stage [psub_cy_pos ]: 10000 Helicity Clock Set [HELCLOCKs ]: Free Clock Helicity Clock Read [HELCLOCKd ]: Free Clock Helicity Delay Set (windows) [HELDELAYs ]: 8 windows Helicity Delay Read (windows) [HELDELAYd ]: 8 windows Helicity Pattern Set [HELPATTERNs ]: Quartet Helicity Pattern Read [HELPATTERNd ]: Quartet Helicity TSettle Read (us) [HELTSETTLEd ]: 70 Helicity TStable Read (us) [HELTSTABLEd ]: 971.65 Helicity Frequency (Hz) [HELFREQ ]: 960.015 ************ Qweak DAQ TS Prescale Factors PS1 (Helicity Window) : 0 (0.000000) PS2 (Trigger Scintillator) : 16777215 (1.000000) PS3 (GEM Trigger Out) : 16777215 (1.000000) PS4 (Main Detector AND-OR) : 16777215 (1.000000) PS5 (Region 2 Scintillator) : 65535 (1.000000) PS6 (Scanner Event Mode) : 65535 (1.000000) PS7 (Charlotte) : 65535 (1.000000) PS8 () : 65535 (1.000000) TS0 keywords: no_tsprogram1 ************ Qweak DAQ VQWK Settings TS0 vqwksamples : 116 TS0 vqwkdelay : 20 TS0 vqwkblocks : 4 TS0 vqwkperiod : 0 TS0 vqwkinternal : 3 ROC1 vqwksamples : 116 ROC1 vqwkdelay : 20 ROC1 vqwkblocks : 4 ROC1 vqwkperiod : 0 ROC1 vqwkinternal : 3 ROC2 vqwksamples : 116 ROC2 vqwkdelay : 20 ROC2 vqwkblocks : 4 ROC2 vqwkperiod : 0 ROC2 vqwkinternal : 3 G0INJ vqwksamples : 116 G0INJ vqwkdelay : 20 G0INJ vqwkblocks : 4 G0INJ vqwkperiod : 0 G0INJ vqwkinternal : 2 ************ R3 Vertical Drift Chamber EPICS variables R3 VDC YODA HV (V) [qwvdc1voltage ]: -2.16763 R3 VDC HAN HV (V) [qwvdc2voltage ]: -20.1852 R3 VDC LEIA HV (V) [qwvdc3voltage ]: -14.0816 R3 VDC VADER HV (V) [qwvdc4voltage ]: 2.7507 ************ R2 Horizontal Drift Chamber EPICS variables R2 HDC Hokie2 Threshold (V) [qw:hk2_thresh ]: 0 R2 HDC Hokie3 Threshold (V) [qw:hk3_thresh ]: 0 R2 HDC Hokie4 Threshold (V) [qw:hk4_thresh ]: 0 R2 HDC Hokie5 Threshold (V) [qw:hk5_thresh ]: 0