Make Followup Entry (Advanced)
User name wdconinc
Log entry time 17:13:13 on November 29, 2011
Entry number 241381
keyword=Compton: ROC2 crash -> init v1495 -> no luck
No luck :-(
...
udpSend: write failure
udpSend: write failure
udpSend: write failure
v1495cpInitAll()
INFO:v1495cpInit:Initialized V1495 slave 1 at address 0x90210000.
eDet V1495 Firmware Revision: 3219
Board IDs: D[0], E[0], F[3]
pV1495CP[1]->Event BUF Addr: 0x90212100
pV1495CP[1]->Accum Data Addr: 0x90212000
pV1495CP[1]->Scalar Data Addr: 0x90213000
pV1495CP[1]->buf_status_REG: 0X90212104
***v1495cpInit Started successfully at local address[0x00210000]...Resetting Module***
Compiled Date: Nov 5 2011 and Time: 07:56:21
INFO:v1495cpInit:Initialized V1495 slave 2 at address 0x90220000.
eDet V1495 Firmware Revision: 3219
Board IDs: D[0], E[0], F[3]
pV1495CP[2]->Event BUF Addr: 0x90222100
pV1495CP[2]->Accum Data Addr: 0x90222000
pV1495CP[2]->Scalar Data Addr: 0x90223000
pV1495CP[2]->buf_status_REG: 0X90222104
***v1495cpInit Started successfully at local address[0x00220000]...Resetting Module***
Compiled Date: Nov 5 2011 and Time: 07:56:21
value = 46 = 0x2e = '.'
-> udpSend: write failure
udpSend: write failure
-> udpSend: write failure
udpSend: write failure
udpSend: write failure
...
A copy of this log entry has been emailed to: narayan