Main INDEX,
Monthly INDEX,
PREV,
NEXT
Make New Entry,
Make Followup Entry (Advanced)
User name DArko
Log entry time 08:08:02 on January 29, 2012
Entry number 250744
keyword=Shift Summary: Owl Shift Summary January 29, 2012
Owl Shift Summary January 29, 2012
Shift Crew
Shift Leader: Darko Androic
Target: Wade Duvall
Virtual, but very usefull: Dave Gaskell
Priorities for this shift
1. Take LH2 parity production data.
Run list
- Run
15553: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT
(100k Analysis )
- Run
15554: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT
(100k Analysis )
- Run
15555: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT
(100k Analysis )
- Run
15556: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
*Extremely short run
- Run
15557: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
*Short run
- Run
15558: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
- Run
15559: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
- Run
15560: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
- Run
15561: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
- Run
15562: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
- Run
15563: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT
(100k Analysis )
Coulombs acquired: 4.88
Key Operating parameters
enter typical values, from EPICS or first 100k analysis
Automatic entry from the first 100k analysis
---------------------------------------------------------
| Run Number: 15559 |
| Qweak Target: HYDROGEN-CELL , 176.3 uA, 4.0x4.0 mm |
---------------------------------------------------------
|I |uA |176.3 uA |
|MDALLBARS width |ppm |228.5 |
|BCM78-ddif width |ppm |63.2 |
|A_q mean |ppm |0.28 |
|A_q width |ppm |394.0 |
|MDALLBARS X-sens. |ppm/mm |881.7+-178.6 |
|MDALLBARS Y-sens. |ppm/mm |2456.4+-185.1 |
|BMOD MDALLBARS X-sens. |ppm/mm |679.9+-372.9 |
|BMOD MDALLBARS Y-sens. |ppm/mm |0.0+-0.0 |
|BMOD MDALLBARS E-sens. |ppm/mm |0.0+-0.0 |
---------------------------------------------------------
Full list of events