Day Shift Summary 06-feb-2012
Shift Crew:
SL: AK Opper
TO: Rob Michaels
3rd:
Others: Dave G, Rob Mahurin, Paul King, Steve Woods
Priorities for shift:
LH2 Production
Summary of events:
09:50 Changed IHWP1 from OUT to IN
13:00 MCC put us in Controlled access for work on BCM.
RadCon and BCM folks arrived at ~ 13:15 to do their work.
Mark D and Brad took advantage of this access to enter the hall and reset some cameras.
Work completed by 13:45, requested beam. Started taking data at 14:10
Run list:
- Run 15811: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT ( 100k Analysis )
- Run 15812: Parity, LH2 production @ 180uA, IHWP1 OUT, IHWP2 OUT ( 100k Analysis )
- Run 15813: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT ( 100k Analysis )
- Run 15814: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT ( 100k Analysis )
- Run 15815: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT ( 100k Analysis )
- Run 15816: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT ( 100k Analysis )
- Run 15817: pedestal
- Run 15818: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT (100k Analysis ) <-- looks crummy because beam had tripped at beginning of run
- Run 15819: Parity, LH2 production @ 180uA, IHWP1 IN, IHWP2 OUT ( 100k Analysis )
Coulombs acquired: 4.15
Typical operating parameters:
I |
uA |
180 |
Halo 3 rate |
Hz/uA |
16 |
MDALLBARS width |
ppm |
224 |
BCM78-ddif width |
ppm |
63 |
A_q width |
ppm |
470 |
MDALLBARS X-pos sensitivity |
ppm/mm |
638 +/-176 |
MDALLBARS Y-pos sensitivity |
ppm/mm |
1466 +/- 228 |
Problems requiring attention:
X
Analysis:
- XXX
Comments: