Main INDEX,
Monthly INDEX,
PREV,
NEXT
Make New Entry,
Make Followup Entry (Advanced)
User name DArko
Log entry time 07:50:30 on February 08, 2012
Entry number 252748
keyword=Shift Summary: Owl Shift Summary February 8, 2012
Owl Shift Summary February 8, 2012
Shift Crew
Shift Leader: Darko Androic
Target: Anna Lee
Priorities for this shift
1. Take Aluminum data.
Run list
- Run
15864:
4% DS Al Parity, Production @ 60 uA, IHWP 1=OUT, IHWP 2=IN
(100 k
Analysis
)
- Run
15865:
4% DS Al Parity, Production @ 60 uA, IHWP 1=OUT, IHWP 2=IN
(100 k
Analysis
)
- Run
15866:
4% DS Al Parity, Production @ 60 uA, IHWP 1=OUT, IHWP 2=IN
(100 k
Analysis
)
- Run
15867:
4% DS Al Parity, Production @ 60 uA, IHWP 1=OUT, IHWP 2=IN
(100 k
Analysis
)
- Run
15868:
4% DS Al Parity, Production @ 60 uA, IHWP 1=IN, IHWP 2=OUT
(100 k
Analysis
) *short run
- Run
15869:
4% DS Al Parity, Production @ 60 uA, IHWP 1=IN, IHWP 2=OUT
(100 k
Analysis
)
- Run
15870: 4% DS Al Parity, Production @ 60 uA, IHWP 1=IN, IHWP 2=OUT
(100 k
Analysis
)
- Run
15871: 4% DS Al Parity, Production @ 60 uA, IHWP 1=IN, IHWP 2=OUT
(100 k
Analysis
)
- Run
15872: 4% DS Al Parity, Production @ 60 uA, IHWP 1=IN, IHWP 2=OUT
(100 k
Analysis
)
- Run
15873: 4% DS Al Parity, Production @ 60 uA, IHWP 1=OUT, IHWP 2=OUT
(100 k
Analysis
)**short run
Coulombs acquired: 1.66
Key Operating parameters
enter typical values, from EPICS or first 100k analysis
Automatic entry from the first 100k analysis
---------------------------------------------------------
| Run Number: 15870 |
| Qweak Target: DS-4%-Aluminum , 60.1 uA, 4.0x4.0 mm |
---------------------------------------------------------
|I |uA |60.1 uA |
|MDALLBARS width |ppm |606.8 |
|BCM78-ddif width |ppm |63.3 |
|A_q mean |ppm |3.17 |
|A_q width |ppm |355.3 |
|MDALLBARS X-sens. |ppm/mm |727.7+-500.0 |
|MDALLBARS Y-sens. |ppm/mm |944.4+-591.1 |
|BMOD MDALLBARS X-sens. |ppm/mm |825.7+-898.9 |
|BMOD MDALLBARS Y-sens. |ppm/mm |0.0+-0.0 |
|BMOD MDALLBARS E-sens. |ppm/mm |0.0+-0.0 |
---------------------------------------------------------
Full list of events
- 00:00
Helicity magnets at:
CH1 (0L01V): even Spt. = 23
odd Spt. = - 23
CH3 (0L03V): even Spt. = 21 odd Spt.
= - 20
- for run# 15864,15865,15866,15867
- 03:45 IHWP#1 form OUT to IN IHWP#2 from IN to OUT
- 04:30
Helicity magnets at:
CH1 (0L01V): even Spt. = 18
odd Spt. = - 17
CH3 (0L03V): even Spt. = 16 odd Spt.
= - 15
- for run# 15868*,15869,15870,15871,15872
- 07:40 IHWP#1 form IN to OUT IHWP#2=OUT, NO change on Helicity magnets