Main INDEX, Monthly INDEX, ,
Make New Entry, Make Followup Entry (Advanced)

User name cdaq

Log entry time 15:59:56 on April 11, 2012

Entry number 263937

keyword=Compton Run 25020 (standard): 877MeV: PWTL2=13, IHWP 1/2 : (IN/OUT) flipper not used: Edet in garage

Experiment compton

Run #25020 (&) - /net/cdaq/compton1/compton/rawdata/standard_25020.dat.0

HV used HV.2010-08-05-23:39:50.hvcHV.2010-08-05-23:39:50.hvc
PS1 1 1
PS2 16777215 16777215
PS3 16777215 16777215
PS4 16777215 16777215
thr1 37003700
thr2 16001600
noffset -170-170
p2t 0xFFFFF7FF0xFFFFF7FF
p3m 0x7FEFFFbF0x7FEFFFbF
p3t 0xFF7FFFFF0xFF7FFFFF
p4t 0x000000000x00000000
pwtl1 1212
pwtl2 1313
pldelay 77
minwidth 11
accumtrig 22
eventtrig 33
Beam Current BCM1 (uA) 4.879554.87955
Beam Current BCM2 (uA) 4.978364.97836
Half Wave Plate ININ
Passive IHWP set (0=IN,1=OUT) 11

HWien=-59.6 deg
VWien=90
I = 180 uA
IHWP 1/2 set IN/OUT
Phi=88.712 deg (flip right)
photonDetector HV = 1750
electronDetector HV = -400