------------------------------------------------------------------------ Run Number : 17948 End of Run Comment: Due to Green monster operation errors, 6000 A and 2000 A were repeated. The second set of each of these is the one to use. There is a short bit of 1800 following the 1800 A set that is bad (was actually 2000). ------------------------------------------------------------------------ ************ Qweak/HallC EPICS variables MPS Beam Current (uA) [IBC3H00CRCUR4 ]: 0.48 Hall C Beam Current BCM1 (uA) [ibcm1 ]: 0.458833 Hall C Beam Current BCM2 (uA) [ibcm2 ]: 0.447881 Hall C Beam Current BCM17 (uA) [ibcm3 ]: -64.3946 Hall C Beam Energy Set (MeV) [MBSY3C_energy ]: 3361.25 Hall C Beam Energy Read (MeV) [HALLC:p ]: 3351.6 Qweak Magnet Current (A) [qw:qt_mps_i_dcct ]: 1999.3 Qweak Magnet Field (Gauss) [Q1HallP ]: -154.798 HalfWave Plate State [IGL1I00DI24_24M ]: IN Qweak Target [QWtgt_name ]: HYDROGEN-CELL Hall C fast feedback Setting [FB_C:FB_On ]: Off Hall C fast feedback Readout [FB_C:status:ON ]: 0 Hall C energy lock [FB_C:use_RF ]: RF On Hall A energy lock [FB_A:use_RF ]: RF Off Raster X (width) (mm) [EHCFR_LIXWidth ]: 4 Raster Y (height) (mm) [EHCFR_LIYWidth ]: 4 ************ Injector EPICS variables Wien Angle (Vertical) [VWienAngle ]: 89.9999 Wien Vertical BDL (Gcm) [MWF1I04.BDL ]: 2649.6 Wien HV Polarity [IGL1I00OD16_4 ]: POSITIVE Wien Electrode Voltage [IGL1I00DAC6 ]: 0 Wien Angle (Solenoids) [Phi_FG ]: -91.9471 Wien BDL (First Solenoid) (Gcm) [MFG1I04A.BDL ]: -1020.5 Wien BDL (Second Solenoid) (Gcm) [MFG1I04B.BDL ]: -1020.5 Wien Angle (Horizontal) [HWienAngle ]: 20.0007 Wien BDL (Gcm) [MWF0I02.BDL ]: 578.3 Wien HV Polarity (Horizontal) [IGL1I00OD16_9 ]: POSITIVE Wien Electrode Voltage (Horizontal)[IGL1I00DAC5 ]: 0 IHWP 1 Setting (off=out) [IGL1I00OD16_16 ]: IN IHWP 1 Readout (off=out) [IGL1I00DI24_24M ]: IN RHWP Rotating half-wave plate [psub_pl_pos ]: 329 IHWP 2 Setting (0=IN,1=OUT) [IGL1I00DIOHWTB.B2 ]: 1 IHWP 2 Readout (13056=IN,8960=OUT) [IGL1I00DIOFLRD ]: 8960 Pockels Cell Voltages Positive [C1068_QDAC01 ]: 40384 Pockels Cell Voltages Negative [C1068_QDAC02 ]: 42046 Hall A IA Setpoints [C1068_QDAC03 ]: 33635 Hall A IA Setpoints [C1068_QDAC04 ]: 33635 Hall A IA Setpoints [C1068_QDAC05 ]: 33635 Hall A IA Setpoints [C1068_QDAC06 ]: 33635 Hall B IA Setpoints [C1068_QDAC07 ]: 32800 Hall B IA Setpoints [C1068_QDAC08 ]: 32800 Hall B IA Setpoints [C1068_QDAC09 ]: 32800 Hall B IA Setpoints [C1068_QDAC10 ]: 32800 Hall C IA Setpoints [C1068_QDAC11 ]: 33411 Hall C IA Setpoints [C1068_QDAC12 ]: 33411 Hall C IA Setpoints [C1068_QDAC13 ]: 33411 Hall C IA Setpoints [C1068_QDAC14 ]: 33411 Pockels Cell ON/OFF [IGL1I00OD16_8 ]: ON Pockels Cell X Stage [cdipc_xpos ]: -0.0024 Pockels Cell Y Stage [cdipc_ypos ]: 0.0024 Wager X Stage [psub_cx_pos ]: 9300 Wager Y Stage [psub_cy_pos ]: 8750 Helicity Clock Settting [HELCLOCKs ]: Free Clock Helicity Clock Readout [HELCLOCKd ]: Free Clock Helicity Delay Setting(windows) [HELDELAYs ]: 8 windows Helicity Delay Readout (windows) [HELDELAYd ]: 8 windows Helicity Pattern Setting [HELPATTERNs ]: Quartet Helicity Pattern Readout [HELPATTERNd ]: Quartet Helicity TSettle Readout (us) [HELTSETTLEd ]: 70 Helicity TStable Readout (us) [HELTSTABLEd ]: 971.65 Helicity Frequency (Hz) [HELFREQ ]: 960.015 ************ Qweak DAQ TS Prescale Factors PS1 (Helicity Window) : 0 (0.000000) PS2 (Trigger Scintillator) : 250 (0.000015) PS3 (GEM Trigger Out) : 0 (0.000000) PS4 (Main Detector AND-OR) : 16777215 (1.000000) PS5 (Region 2 Scintillator) : 65535 (1.000000) PS6 (Scanner Event Mode) : 65535 (1.000000) PS7 (Charlotte) : 65535 (1.000000) PS8 () : 0 (0.000000) TS0 keywords: no_tsprogram1 ************ Qweak DAQ VQWK Settings TS0 vqwksamples : 4170 TS0 vqwkdelay : 20 TS0 vqwkblocks : 4 TS0 vqwkperiod : 0 TS0 vqwkinternal : 3 ROC1 vqwksamples : 4170 ROC1 vqwkdelay : 20 ROC1 vqwkblocks : 4 ROC1 vqwkperiod : 0 ROC1 vqwkinternal : 3 ROC2 vqwksamples : 4170 ROC2 vqwkdelay : 20 ROC2 vqwkblocks : 4 ROC2 vqwkperiod : 0 ROC2 vqwkinternal : 3 G0INJ vqwksamples : 116 G0INJ vqwkdelay : 20 G0INJ vqwkblocks : 4 G0INJ vqwkperiod : 0 G0INJ vqwkinternal : 2 ************ R3 Vertical Drift Chamber EPICS variables R3 VDC YODA HV (V) [qwvdc1voltage ]: -1.54803 R3 VDC HAN HV (V) [qwvdc2voltage ]: -19.486 R3 VDC LEIA HV (V) [qwvdc3voltage ]: -13.4435 R3 VDC VADER HV (V) [qwvdc4voltage ]: 3.40079 ************ R2 Horizontal Drift Chamber EPICS variables R2 HDC Hokie2 Threshold (V) [qw:hk2_thresh ]: 0 R2 HDC Hokie3 Threshold (V) [qw:hk3_thresh ]: 0 R2 HDC Hokie4 Threshold (V) [qw:hk4_thresh ]: 0 R2 HDC Hokie5 Threshold (V) [qw:hk5_thresh ]: 0