Jefferson Lab Hall C Logbook for May 12 - Target
Main INDEX
Thursday
271272 05/31/12 12:27 covrig Target: position measurements warm/cold/warm
Wednesday
Tuesday
271214 05/29/12 09:58 covrig Target: warm position "survey" (the last one)
Monday
Sunday
Saturday
Friday
271153 05/25/12 13:38 smithg Target: warming up target for the very last time (sniff sniff)...
271152 05/25/12 12:58 Silviu/Adesh Target: cold motion measurement
Thursday
271127 05/24/12 18:00 smithg Target: starting 15K cooldown
271126 05/24/12 17:37 Adesh Target: warm gas measurement done
Wednesday
271081 05/23/12 14:56 Adesh Target: tripod intact
Tuesday
270941 05/22/12 09:07 covrig Target: status of 15K cooldown
Monday
270926 05/21/12 15:21 smithg Target: starting 15 K cooldown
270922 05/21/12 12:10 smithg,covri Target: target cold motion status
Sunday
Saturday
Friday
270893 05/18/12 15:52 adesh Target: cold motion measurement plan
270892 05/18/12 13:55 covrig, smit Target: boiling off LH2
270866 05/18/12 08:35 dunne Target: Pump scans
270840 05/18/12 05:23 dunne Target: Target: screenshots during Owl
270827 05/18/12 04:36 dunne Target: Changing pump frequencies during the remainder of shift
270824 05/18/12 04:04 dunne Target: Pump tripped due to pilot error
Thursday
270771 05/17/12 19:53 alee Target: Swing shift screenshot
270662 05/17/12 12:05 smithg Target: disabled low heater power alarms
270560 05/17/12 03:56 covrig Target: s-harp scans done, moved target to LH2
270558 05/17/12 03:44 covrig Target: moved target HOME & target screens shot
270501 05/17/12 00:11 covrig Target: moved to LH2
Wednesday
270488 05/16/12 22:42 alee Target: Target moved to HOME
270470 05/16/12 21:06 alee Target: Moved target to HYDROGEN CELL after energy measurement is done
270469 05/16/12 21:00 alee Target: Swing shift target screenshots
270452 05/16/12 18:25 alee Target: Target moved home to HOME in preparation for energy measurement
270406 05/16/12 14:06 rob Target: more glitches in qw:tempsanitydiff
270379 05/16/12 09:12 rob Target: Target: screenshots at the beginning of Day Shift
270366 05/16/12 07:55 Pitt Target: End of day shift screenshots
270357 05/16/12 04:11 covrig Target: owl screens shot
Tuesday
270350 05/15/12 23:17 jdowd Target: Target screenshots, end of swing shift
270331 05/15/12 19:25 jdowd Target: Target screenshots
270211 05/15/12 08:21 rob Target: Target: screenshots at the beginning of Day Shift
270201 05/15/12 07:37 Pitt Target: Target:screenshots at end of owl shift
270157 05/15/12 03:35 covrig Target: Owl shift target screenshot
Monday
270134 05/14/12 23:30 jdowd Target: Target screenshots
270070 05/14/12 16:06 jdowd Target: Target screenshots, beginning of swing shift
269980 05/14/12 00:42 covrig Target: owl shift target screens shot
Sunday
269949 05/13/12 20:32 rakithab Target: Moved target to HYDROGEN CELL
269935 05/13/12 19:13 rakithab Target: Move out of beam
269912 05/13/12 17:17 rakithab Target: screenshots at the beginning of Swing Shift
269817 05/13/12 03:58 covrig Target: owl screens shot - mid-shift
269798 05/13/12 00:21 Page Target: target screenshots, start of owl shift
Saturday
269774 05/12/12 20:23 Page Target: Glitch in 4K temp - yellow alarm
269750 05/12/12 16:39 Page Target: screen shot, early in swing shift
269705 05/12/12 10:22 dunne Target: target pc crashed
269704 05/12/12 10:19 dunne Target: Target screen shot
269657 05/12/12 02:15 covrig Target: target screens shot (and 4K blip)
Friday
269640 05/11/12 23:52 Page Target: screenshots, end of swing shift
269608 05/11/12 18:17 Page Target: target ladders heating up according to plan
269605 05/11/12 17:50 Page Target: Moved target to US Al 2%
269573 05/11/12 15:34 vardan Target: closed 15K JT valve by 1.5% (late entry)
269571 05/11/12 15:26 vardan Target: moved LH2 target in
269551 05/11/12 14:26 vardan Target: moved to DS-4% Al
269531 05/11/12 12:52 vardan Target: oscillations during the Moller solenoid warm up
269495 05/11/12 08:50 vardan Target: Target: screenshots at the beginning of Day Shift
269483 05/11/12 07:18 covrig Target: moved to Liquid Hydrogen target
269463 05/11/12 06:32 covrig Target: US-2%-Al at 110 uA
269453 05/11/12 06:02 covrig Target: moved to DS-4%-Al
269434 05/11/12 02:37 covrig Target: owl target screens shot
269425 05/11/12 01:10 covrig Target: moved to US2%Al
Thursday
269389 05/10/12 21:30 Page Target: Low heater power oscillations
269366 05/10/12 20:14 Page Target: Screenshots, beam back at 180 uA
269353 05/10/12 19:24 Page Target: adjusted Moller quad alarm settings for normal production
269352 05/10/12 19:17 Page Target: Moved target to HYDROGEN CELL
269320 05/10/12 16:59 Page Target: target screenshots, Moller studies, target out of beam
269298 05/10/12 14:29 vardan Target: camera flickering
269291 05/10/12 13:41 vardan Target: day shift screenshot
269281 05/10/12 11:58 rob Target: "target controls" camera still flickers after replacement
269254 05/10/12 08:50 vardan Target: Changed Moller quad alarm limits
269251 05/10/12 08:25 vardan Target: moved out of beam
269241 05/10/12 07:46 alee Target: High power heater alarms after beam trip
269218 05/10/12 04:01 alee Target: Owl shift target screenshot
Wednesday
269182 05/09/12 22:01 Page Target: Beam back, target ion chamber rates a little high - upped yellow alarm from 200 to 210 r/h
269174 05/09/12 20:09 Page Target: Screenshots, getting ready for beam, middle of swing shift
269172 05/09/12 20:00 Page Target: Change to operational restrictions for 2% US Al targets
269152 05/09/12 15:44 neven Target: screenshots at the end of Day Shift
269111 05/09/12 08:17 neven Target: screenshots at the beginning of Day Shift
269078 05/09/12 04:26 alee Target: Target Control camera seems to be occasionally flickering
269075 05/09/12 04:10 alee Target: Owl shift target screenshot
Tuesday
268976 05/08/12 15:46 neven Target: screenshots at the end of Day Shift
268925 05/08/12 09:25 neven Target: changed Moller Quad current limits
268916 05/08/12 08:20 neven Target: moved target to LIQUID HYDROGEN
268915 05/08/12 08:17 neven Target: screenshots at the beginning of Day Shift
268892 05/08/12 04:32 alee Target: Owl shift target screenshot
Monday
268859 05/07/12 23:53 Pitt Target: Target screenshots at end of swing shift
268856 05/07/12 23:43 Pitt Target: Tungsten plug return temp was alarming, but fixed with vmec1 reboot
268821 05/07/12 18:29 Pitt Target: Changed HIGH limit on Horizontal Resistive Pot Stepper Mismatch
268818 05/07/12 18:23 Pitt Target: Changed large Moller quad alarm limits
268815 05/07/12 18:00 Pitt Target: Move target to DS-4% Al - late entry
268814 05/07/12 17:59 Pitt Target: Upstream dummy central target temperature alarm during 2% US Al running
268798 05/07/12 16:58 Pitt Target: Move target to US - 2% Aluminum
268777 05/07/12 15:44 neven Target: screenshots at the end of Day Shift
268771 05/07/12 14:46 covrig Target: what's in a name?
268768 05/07/12 14:05 neven Target: moved target to LIQUID HYDROGEN
268760 05/07/12 13:33 wdconinc Target: MCC asks: "what's the hole made of?"
268759 05/07/12 13:30 neven Target: Moved to DS- Centering hole
268752 05/07/12 13:17 neven Target: power stage error on the end of horizontal motion
268749 05/07/12 13:07 neven Target: moved target to HOME (Out of beam)
268705 05/07/12 08:20 neven Target: screenshots at the beginning of Day Shift
268675 05/07/12 05:40 alee Target: Owl shift sceenshot
268662 05/07/12 03:42 alee Target: Tungsten plug return temp is alarming
268645 05/07/12 00:45 alee Target: Beeping alarm continues after alarm is silenced/ fixed
Sunday
268622 05/06/12 22:28 Page Target: Screen shot, 60 uA on 4% DS Al
268615 05/06/12 21:58 Page Target: Moved to DS Al 4% target
268611 05/06/12 21:40 Page Target: dump window tdiff issue
268552 05/06/12 16:14 Page Target: Moved target to HYDROGEN CELL
268542 05/06/12 15:45 neven Target: screenshots at the end of Day Shift
268541 05/06/12 15:44 neven Target: moved to DS -1.6% Carbon
268525 05/06/12 14:49 neven Target: moved target to LIQUID HYDROGEN
268518 05/06/12 14:39 neven Target: moved target to OPTICS-15
268507 05/06/12 14:11 neven Target: Moved to DS- 4% Aluminum target
268488 05/06/12 12:43 neven Target: moved target to LIQUID HYDROGEN
268479 05/06/12 12:18 nenen Target: Moved to DS - 4% Aluminum
268471 05/06/12 12:02 neven Target: Moved to US- 2% Aluminum
268463 05/06/12 11:44 neven Target: Moved to US - 4% Aluminum
268453 05/06/12 11:26 neven Target: Moved to US - 1% Aluminum target
268435 05/06/12 10:50 neven Target: Moved US - 2% Aluminum target
268393 05/06/12 08:01 neven Target: screenshots at the beginning of Day Shift
268385 05/06/12 07:03 alee Target: Moved target to DS-4% Al
268378 05/06/12 06:46 alee Target: Target moved to optics 135
268369 05/06/12 06:22 alee Target: Target moved to Optics 15
268364 05/06/12 05:57 alee Target: Target moved to DS-1.6%-C
268333 05/06/12 03:31 alee Target: Owls shift target screenshot
Saturday
268282 05/05/12 23:14 Page Target: Horizontal motion power stage error and recovery -- move to HYDROGEN CELL
268272 05/05/12 22:43 Page Target: Moved to 4 % DS aluminum
268268 05/05/12 22:31 Page Target: Moved target to OPTICS-135
268262 05/05/12 22:20 Page Target: moved to OPTICS-15 target
268237 05/05/12 20:14 Page Target: screenshots, middle of swing shift
268185 05/05/12 17:57 Page Target: Move target to HYDROGEN
268166 05/05/12 17:30 Page Target: moved to 1.6% DS C target
268153 05/05/12 16:55 Page Target: vertical motion amp fault - and remedy --> LH2 in
268138 05/05/12 15:51 neven Target: moved target to OPTICS-135
268136 05/05/12 15:42 neven Target: target scan at the end of the Day Shift
268134 05/05/12 15:37 neven Target: moved target to OPTICS-15
268132 05/05/12 15:35 neven Target: motion alarm
268130 05/05/12 15:27 neven Target: Moved to DS- 4% Aluminum target
268104 05/05/12 13:29 neven Target: tungsten plug diff -0.7
268102 05/05/12 13:20 neven Target: moved target to HYDROGEN
268095 05/05/12 13:06 neven Target: moved target to OPTICS-135
268089 05/05/12 12:52 neven Target: moved target to OPTICS-15
268085 05/05/12 12:39 neven Target: moved to DS 4% Aluminum
268056 05/05/12 10:13 neven Target: moved target to HYDROGEN
268054 05/05/12 10:09 neven Target: Moved DS- 4% Aluminum target IN
268051 05/05/12 10:07 neven Target: Moved DS- 4% target IN
268015 05/05/12 08:00 neven Target: target scan at the beginnig of the Day Shift
267993 05/05/12 06:02 alee Target: Target move to LH2
267965 05/05/12 04:15 alee Target: Target moved to HOME
267958 05/05/12 03:54 alee Target: Owl shift target screenshot
Friday
267913 05/04/12 20:19 Page Target: mid shift screen shots for target
267865 05/04/12 15:38 vardan Target: target screenshot at the end of day shift
267858 05/04/12 15:10 vardan Target: moved LH2 target in
267786 05/04/12 09:21 vadan Target: Large moller quad high limits changed
267785 05/04/12 09:03 vardan Target: moved LH2 target out
267775 05/04/12 08:33 vardan Target: target screenshots, beginning of day shift
Thursday
267696 05/03/12 20:16 Page Target: mid shift screen shots for target
267658 05/03/12 15:45 vardan Target: end of day shift screenshots
267637 05/03/12 12:28 Nuruzzaman Target: Online target status page is UP now.
267634 05/03/12 11:46 vardan Target: target ion chamber rates high
267618 05/03/12 10:06 vardan Target: target screenshot by 2 hours in day shift
Wednesday
267517 05/02/12 15:51 smithg Target: 4K return improved again
267512 05/02/12 15:23 vardan Target: changed HI limit on Qtor current difference
267511 05/02/12 15:22 smithg Target: xfer line pumping helped, then got worse again
267508 05/02/12 14:45 vardan Target: Changed Moller quad alarm limits
267499 05/02/12 13:24 vardan Target: drop in 4K flow
267495 05/02/12 12:18 vardan Target: target screenshot at the middle of day shift
267453 05/02/12 07:15 wsduvall Target: Moved target to LH2
267410 05/02/12 05:44 wsduvall Target: Moved target to DS-4% Al
Tuesday
267329 05/01/12 22:38 magee Target: moved to lh2
267320 05/01/12 21:47 magee Target: moved to DS 1.6% carbon
267317 05/01/12 21:15 magee Target: moved to US 4% Aluminum
267309 05/01/12 20:43 magee Target: moved to 2% US aluminum
267302 05/01/12 20:11 magee Target: moved to 1% US aluminum
267295 05/01/12 19:46 magee Target: moved to DS 8% Aluminum
267289 05/01/12 19:16 magee Target: moved to 2% DS aluminum
267286 05/01/12 18:54 magee Target: Appears to be back at full power
267276 05/01/12 17:20 smithg Target: Should be back to full power in ~ 1/2h
267275 05/01/12 17:18 magee Target: Back to 29 Hz on the pump
267261 05/01/12 16:04 rob Target: alarm limit change reverted
267259 05/01/12 15:54 smithg Target: CHL C6 recovered. Beginning to recover 4K flow to Hall C.
267254 05/01/12 15:18 rob Target: changed LOWLOW alarm on QW_FI_4K from 7 g/s to 5 g/s
267252 05/01/12 15:08 rob Target: changed LOWLOW alarm on QW_FI_4K from 6 g/s to 7 g/s
267251 05/01/12 15:03 rob Target: the adventure begins
267249 05/01/12 14:59 smithg Target: Recovered. But a new problem at CHL means 4K flow will be cut again
267248 05/01/12 14:59 rob Target: another CHL trip
267239 05/01/12 14:08 rob Target: alarm limit change reverted
267237 05/01/12 13:56 rob Target: alarm limit change reverted
267236 05/01/12 13:51 smithg Target: Cryo starting to slowly restore our 4K flow
267234 05/01/12 13:26 rob Target: changed LOW alarm on QW_FI_4K from 8 g/s to 11 g/s
267233 05/01/12 13:25 smithg Target: Cryo has restarted C6, we're off the SBR. SHould start to recover.
267232 05/01/12 13:06 rob Target: no alarms for about 20 minutes
267231 05/01/12 12:36 rob Target: red alarm: 4k flow dipped below 6 g/s
267230 05/01/12 12:21 smithg Target: CHL compressor problems: preparing tgt for a rough ride
267229 05/01/12 12:20 rob Target: screenshot
267228 05/01/12 12:19 rob Target: fasten seat belts, trouble at cryo; pump speed reduced
267223 05/01/12 09:32 rob Target: target screenshots, beginning of day shift
267171 05/01/12 00:15 narayan Target: auxilliary heater's pot set to 940