keyword=Target Shift Checklist
Status of Cryogenic Targets
*****************************
00:09:53 Tue Dec 9 1997
Cryogenics
Coolant Flow 7.59gm/s
Supply EV9130 26.196%
H2 Bypass EV9133 14.258%
D2 Bypass EV9134 3.271%
Supply T TD9131 14.500K
Return T TD9143 21.000K
Supply P PT9144 218.170PSIA
Supply EV9125 74.854%
Return T TI9125 241.600K
H2 Target
Target T TV9196 19.819K
Target T TI9019 18.990K
Target T TI9018 19.000K
Target P PT9013 27.440PSIA
Target P PT9023 26.000PSIA
Pump V P9090 24.75V
Pump I(mA) P9090 1751.00mA
Pump Frequency P9090 0.000Hz
Low Power HR9120 0.000W
High Power HR9121 21.910W
D2 Target
Target T TV9126 21.791K
Target T TI9089 22.000K
Target T TI9088 22.000K
Target P PT9083 19.730PSIA
Target P PT9093 20.550PSIA
Pump V P9020 30.72V
Pump I(mA) P9020 4064.00mA
Pump Frequency P9020 0.000Hz
Low Power HR9190 0.000W
High Power HR9191 16.175W
He Target
Target T TI9182 18.990K
Pump V P9080 8.045V
Pump I P9080 -0.152A
Pump Frequency P9080 0.000Hz
Low Power HR9180 0.000W