Main INDEX
Monthly INDEX
PREV
NEXT
User name cdaq
Log entry time 00:36:02 on March 16, 1998
Entry number 4421
keyword=Target Shift Checklist
Status of Cryogenic Targets
*****************************
00:20:41 Mon Mar 16 1998
Cryogenics
Coolant Flow 8.55gm/s
Supply EV9130 26.221%
H2 Bypass EV9133 11.035%
D2 Bypass EV9134 2.734%
Supply T TD9131 13.900K
Return T TD9143 20.100K
Supply P PT9144 22.850PSIA
Supply EV9125 71.729%
Return T TI9125 0.000K
JTswitch Sup TD9180 14.300K
JTswitch Ret TD9178 21.700K
H2 Target
Target T TI9020 15.730K
Target T TI9019 15.690K
Target T TI9018 15.690K
Target P PT9013 22.710PSIA
Target P PT9023 22.690PSIA
He4 Target P PI9103 29.040PSIA
Pump V P9090 5.94V
Pump I(mA) P9090 0.00mA
Pump Frequency P9090 0.000Hz
Low Power HR9120 0.000W
High Power HR9121 0.046W
D2 Target
Target T TI9090 22.290K
Target T TI9089 22.010K
Target T TI9088 22.000K
Target P PT9083 19.520PSIA
Target P PT9093 19.530PSIA
Pump V P9020 32.00V
Pump I(mA) P9020 3753.00mA
Pump Frequency P9020 63.000Hz
Low Power HR9190 0.000W
High Power HR9191 90.091W
He Target
Target T TI9182 18.030K
Target T TI9183 18.000K
Target T TI9184 18.020K
Target P PI9714 20.480PSIA
Compressor T TD9701 301.900K
Compressor P PI9715 14.730PSIA
Pump V P9080 3.599V
Pump I P9080 0.489A
Pump Frequency P9080 62.000Hz
Low Power HR9180 0.000W
High Power HR9181 -130.740W