• Main INDEX
  • Monthly INDEX
  • PREV
  • NEXT

    User name cdaq

    Log entry time 03:36:55 on June 29, 1998

    Entry number 6181

    Followups:

    keyword=Run 20104: Check of the 0,0 beam position after beam tuning

    Run #20104 (main) - ./

    Beam Energy (MeV) 4.1064.106
    HMS Momentum (GeV/c) 3.89623.8962
    HMS Angle 15.5015.50
    Q1 Set Current 506.588506.48
    Q2 Set Current -403.038-403.03
    Q3 Set Current 198.545197.9
    Q1 B Field (G) 6936.39996936.4
    Q2 B Field (G) -8204.3000-8204.3
    Q3 B Field (G) 4006.70004006.9
    D Current Readback -1198.230-1198.3
    B_true -1.0676979-1.0676900
    Target Encoder 1059510595

    Check of the 0,0 beam position after beam tuning

    echmsq1i_set_s506.588
    echmsq2i_set_s-403.038
    echmsq3i_set_s198.545
    echmsdimeas2_s-1198.23
    echmsdb_true_s-1.0677
    Rast_TargWidth1
    EHCRT_IXPEAK
    EHCRT_IYPEAK
    EHCRT_ENGERY
    EHCRT_INITENGERY
    EHCRT_INITILIMIT1.2