Beam Energy (MeV) | 5571 | 5571 |
HMS Momentum (GeV/c) | 5.181 | 5.181 |
HMS Angle | 20.60 | 20.58 |
SOS Momentum (GeV/c) | 1.7395 | 1.7395 |
SOS Angle | 58.21 | 58.21 |
Target NUMBER | 12 | 12 |
HMS Q1 Set Current | -673.162 | -673.06 |
HMS Q2 Set Current | 536.475 | 536.45 |
HMS Q3 Set Current | -264.232 | -263.19 |
HMS Q1 B Field (G) | 0.0000 | -9.2453 |
HMS Q2 B Field (G) | 0.0000 | 10.8986 |
HMS Q3 B Field (G) | 0.0000 | -5.3410 |
HMS D Current Readback | 1630.230 | 1627.95 |
HMS B_true | 0.0000000 | 1.423794 |
SOS Q Set Current | 697.80 | 697.8 |
SOS Q Field | 10892.00 | 10892.00 |
SOS B1 Set Current | 985.38 | 985.38 |
SOS B1 Hall Probe | 19824.50 | 19824.5 |
SOS B2 Set Current | 787.04 | 787.05 |
SOS B2 Hall Probe | -20185.50 | -20185.00 |
SOS 12cm H2; 4% radiator
HMS no PID, SOS no PID
40 uA
ps1 = 10000
ps2 = 1
ps3 = 10000
HMS trigger: 4/4.
SOS trigger: 4/4
echmsq1i_set_s | -673.162 |
echmsq2i_set_s | 536.475 |
echmsq3i_set_s | -264.232 |
echmsdimeas2_s | 1630.23 |
echmsdb_true_s | |
Rast_TargWidth | 2 |
EHCRT_IXPEAK | 24.167 |
EHCRT_IYPEAK | 23.998 |
EHCRT_ENGERY | |
EHCRT_INITENGERY | |
EHCRT_INITILIMIT | 30 |