    User name S. Strauch

    Log entry time 09:02:00 on April 14,1999

    Entry number 11922

    This entry is a followup to: 11897

    keyword=Charge calibration of run #24310.

    Charge calibration of run #24310.
    The results are the following

    run: 24310.
    unser (Hz)
    519514.8
    518765.8
    518696.6
    518890.4
    518887.2
    517376.9
    516902.6
    598289.1
    679024.4
    759303.6
    599042.1
    677325.9
    760087.2
    Current(muA) BCM1(Hz) BCM2(Hz) BCM3(Hz) Weight
    0.0 250306.2 250288.8 249147.1 92.0
    19.9 321877.9 319917.6 287988.6 17.0
    40.1 393946.7 390196.3 327934.6 16.0
    60.2 466542.2 461103.5 368120.4 16.0
    20.1 321771.8 319886.0 287952.8 15.0
    39.7 393179.3 389541.1 327520.1 13.0
    60.4 467185.7 461714.0 368469.5 5.0
    gain factors for three cavity monitors
    gbcm1_gain = 0.00027763 ; microA/Hz
    gbcm2_gain = 0.00028456 ; microA/Hz
    gbcm3_gain = 0.00050127 ; microA/Hz
    gunser_gain = 0.00025006 ; microA/Hz
    zero offsets for BCM s
    gbcm1_offset = 249683. ; Hz
    gbcm2_offset = 249504. ; Hz
    gbcm3_offset = 248021. ; Hz
    gunser_offset = 518520. ; Hz