Beam Energy (MeV) | 5571 | 5571 |
HMS Momentum (GeV/c) | 5.15 | 5.15 |
HMS Angle | -1.00 | 12.84 |
SOS Momentum (GeV/c) | -1.268 | -1.268 |
SOS Angle | -1.00 | 64.65 |
Target NUMBER | 11 | 11 |
HMS Q1 Set Current | -669.100 | -669.02 |
HMS Q2 Set Current | 533.125 | 533.100 |
HMS Q3 Set Current | -262.624 | -261.61 |
HMS Q1 B Field (G) | -9167.4004 | -91669 |
HMS Q2 B Field (G) | 10825.4000 | 10824.2 |
HMS Q3 B Field (G) | -5295.3000 | -5.2976 |
HMS D Current Readback | 1618.110 | 1618.11 |
HMS B_true | 1.4151223 | 1.4151236 |
SOS Q Set Current | 497.47 | 497.47 |
SOS Q Field | -8014.00 | -8014.00 |
SOS B1 Set Current | 603.98 | 603.98 |
SOS B1 Hall Probe | -14454.00 | -14453.5 |
SOS B2 Set Current | 509.82 | 509.82 |
SOS B2 Hall Probe | 14714.00 | 14714.50 |
H(e,e'p) Some HMS Cal HV off
raster size = 1.0 mm
I=52uA
HMS trigger 3/4
SOS 3/4
ps1=20
ps2=1
ps3=1
echmsq1i_set_s | -669.1 |
echmsq2i_set_s | 533.125 |
echmsq3i_set_s | -262.636 |
echmsdimeas2_s | 1618.2 |
echmsdb_true_s | 1.41512 |
Rast_TargWidth | 1 |
EHCRT_IXPEAK | 11.999 |
EHCRT_IYPEAK | 12.675 |
EHCRT_ENGERY | |
EHCRT_INITENGERY | |
EHCRT_INITILIMIT | 50 |