Beam Energy (MeV) | 5571 | 5571 |
HMS Momentum (GeV/c) | 5.15 | 5.15 |
HMS Angle | ERR | 12.84 |
SOS Momentum (GeV/c) | -1.268 | -1.268 |
SOS Angle | ERR | 64.65 |
Target NUMBER | 17 | 17 |
HMS Q1 Set Current | ERR | -669.02 |
HMS Q2 Set Current | ERR | 533.100 |
HMS Q3 Set Current | ERR | -261.61 |
HMS Q1 B Field (G) | -9168.2998 | -91669 |
HMS Q2 B Field (G) | 10824.8000 | 10824.2 |
HMS Q3 B Field (G) | -5294.7000 | -5.2976 |
HMS D Current Readback | ERR | 1618.11 |
HMS B_true | ERR | 1.4151236 |
SOS Q Set Current | 497.47 | 497.47 |
SOS Q Field | -8014.00 | -8014.00 |
SOS B1 Set Current | 603.98 | 603.98 |
SOS B1 Hall Probe | -14453.50 | -14453.5 |
SOS B2 Set Current | 509.82 | 509.82 |
SOS B2 Hall Probe | 14713.50 | 14714.50 |
(e,e'p) 60 uA, Dummy Target
raster size = 1.0 mm
I=60uA
HMS trigger 3/4
SOS 3/4
ps1=200
ps2=10
ps3=1
echmsq1i_set_s | |
echmsq2i_set_s | |
echmsq3i_set_s | |
echmsdimeas2_s | |
echmsdb_true_s | |
Rast_TargWidth | 1 |
EHCRT_IXPEAK | 11.83 |
EHCRT_IYPEAK | 12.844 |
EHCRT_ENGERY | |
EHCRT_INITENGERY | |
EHCRT_INITILIMIT | 50 |