Beam Energy (MeV) | 5.571 | 5.571 |
HMS Momentum (GeV/c) | 5.150 | 5.150 |
HMS Angle | -1.00 | -1.00 |
SOS Momentum (GeV/c) | -1.286 | -1.286 |
SOS Angle | -1.00 | -1.00 |
Target NUMBER | 2 | 2 |
HMS Q1 Set Current | -669.100 | -669.100 |
HMS Q2 Set Current | 533.125 | 533.125 |
HMS Q3 Set Current | -262.599 | -262.599 |
HMS Q1 B Field (G) | -9168.5000 | -9168.5000 |
HMS Q2 B Field (G) | 10822.8000 | 10822.8000 |
HMS Q3 B Field (G) | -5287.1000 | -5287.1000 |
HMS D Current Readback | 1618.110 | 1618.110 |
HMS B_true | 1.4151216 | 1.4151216 |
SOS Q Set Current | 497.47 | 497.47 |
SOS Q Field | -8018.00 | -8018.00 |
SOS B1 Set Current | 604.47 | 604.47 |
SOS B1 Hall Probe | -14452.00 | -14452.00 |
SOS B2 Set Current | 510.13 | 510.13 |
SOS B2 Hall Probe | 14713.50 | 14713.50 |
(e,e'p) - 30 muA, (x>1) Fe target
(approx 2 mm higher than nominal)
raster size = 1.0 mm, 63 HZ
HMS trigger 3/4
SOS PID (C)
ps1=200
ps2=1
ps3=1
echmsq1i_set_s | -669.1 |
echmsq2i_set_s | 533.125 |
echmsq3i_set_s | -262.599 |
echmsdimeas2_s | 1618.11 |
echmsdb_true_s | 1.41512 |
Rast_TargWidth | 1 |
EHCRT_IXPEAK | 11.83 |
EHCRT_IYPEAK | 11.323 |
EHCRT_ENGERY | |
EHCRT_INITENGERY | |
EHCRT_INITILIMIT | 65 |