    Log entry time 08:27:10 on July 22, 1999

    Entry number 14520

    keyword=Run 25660: test run to check DAQ at start of energy measurement.

    Run #25660 (coin) - /cdaqs1/data4/daq99_25660.log

    Beam Energy (MeV) 5.4985.498
    HMS Momentum (GeV/c) -4.650-4.650
    HMS Angle 13.0013.02
    SOS Momentum (GeV/c) +1.368+1.368
    SOS Angle 46.9146.91
    Target NUMBER 1111
    HMS Q1 Set Current 534.500604.02
    HMS Q2 Set Current -424.987-480.37
    HMS Q3 Set Current 209.737236.19
    HMS Q1 B Field (G) 7342.500038.2979
    HMS Q2 B Field (G) -8650.7000-9.7742
    HMS Q3 B Field (G) 4231.60004.7801
    HMS D Current Readback -1267.050-1435.9
    HMS B_true -1.1280261-1.27589
    SOS Q Set Current 661.29661.29
    SOS Q Field 10412.0010412.00
    SOS B1 Set Current 897.96897.97
    SOS B1 Hall Probe 18930.5018931.50
    SOS B2 Set Current 712.28712.28
    SOS B2 Hall Probe -19272.00-19272.50

    test run to check DAQ at start of energy measurement.
    e94-110 production LH2 (W2, Q2, eps = 1.19, 1.31, 0.96)
    beam current=60 uA
    HMS 3/4 electron + prescaled pions (A+B)
    SOS 3/4electron + prescaled pions (A+B)

    ps1=8
    ps2 = 8
    ps3 = 9999999
    echmsq1i_set_s534.5
    echmsq2i_set_s-424.987
    echmsq3i_set_s209.737
    echmsdimeas2_s-1267.08
    echmsdb_true_s-1.12803
    Rast_TargWidth
    EHCRT_IXPEAK24.038
    EHCRT_IYPEAK11.662
    EHCRT_ENGERY
    EHCRT_INITENGERY
    EHCRT_INITILIMIT60