Beam Energy (MeV) | 5.498 | 5.498 |
HMS Momentum (GeV/c) | -3.901 | -3.901 |
HMS Angle | 15.50 | 15.50 |
SOS Momentum (GeV/c) | +1.661 | +1.661 |
SOS Angle | 46.91 | 46.91 |
Target NUMBER | 11 | 11 |
HMS Q1 Set Current | 506.800 | 506.71 |
HMS Q2 Set Current | -402.850 | -402.90 |
HMS Q3 Set Current | 198.783 | 198.10 |
HMS Q1 B Field (G) | 6961.0000 | 6960.9000 |
HMS Q2 B Field (G) | -8200.1000 | -8200.1000 |
HMS Q3 B Field (G) | 4011.4000 | 4011.5000 |
HMS D Current Readback | -1196.130 | -1196.16 |
HMS B_true | -1.0691407 | -1.0691406 |
SOS Q Set Current | 661.81 | 661.81 |
SOS Q Field | 10416.00 | 10416.00 |
SOS B1 Set Current | 897.96 | 897.96 |
SOS B1 Hall Probe | 18928.00 | 18928.00 |
SOS B2 Set Current | 712.28 | 712.28 |
SOS B2 Hall Probe | -19268.50 | -19268.50 |
e94-110 production dummy (W2, Q2, eps = 2.35,1.53,0.91)
singles
beam current=60 uA
HMS 3/4 electron + prescaled pions (A+B)
SOS 3/4 electron + prescaled pions (A+B)
ps1=25
ps2 = 5
ps3 = 9999999
echmsq1i_set_s | 506.8 |
echmsq2i_set_s | -402.863 |
echmsq3i_set_s | 198.783 |
echmsdimeas2_s | -1196.22 |
echmsdb_true_s | -1.06914 |
Rast_TargWidth | |
EHCRT_IXPEAK | 24.038 |
EHCRT_IYPEAK | 11.662 |
EHCRT_ENGERY | |
EHCRT_INITENGERY | |
EHCRT_INITILIMIT | 60 |