Beam Energy (MeV) | 5510 | 5498 |
HMS Momentum (GeV/c) | -2.482 | -2.482 |
HMS Angle | 28.00 | 28.00 |
SOS Momentum (GeV/c) | +1.661 | +1.661 |
SOS Angle | 46.91 | 46.91 |
Target NUMBER | 11 | 11 |
HMS Q1 Set Current | 322.400 | 322.34 |
HMS Q2 Set Current | -256.188 | -256.25 |
HMS Q3 Set Current | 126.224 | 125.94 |
HMS Q1 B Field (G) | 4425.9000 | 4426.000 |
HMS Q2 B Field (G) | -5215.8000 | -5215.7000 |
HMS Q3 B Field (G) | 2547.3000 | 2546.6000 |
HMS D Current Readback | -765.240 | -757.080 |
HMS B_true | -0.6711195 | -0.6801426 |
SOS Q Set Current | 661.81 | 661.81 |
SOS Q Field | 10418.00 | 10418.00 |
SOS B1 Set Current | 897.96 | 897.96 |
SOS B1 Hall Probe | 18927.50 | 18927.50 |
SOS B2 Set Current | 712.55 | 712.55 |
SOS B2 Hall Probe | -19271.50 | -19271.50 |
e94-110 production H (W2, Q2, eps = 3.37, 3.21, 0.768
beam current= 60 uA
HMS 3/4 electron + prescaled pions (A+B)
SOS 3/4 electron + prescaled pions (A+B)
ps1=1
ps2=2
ps3 = 9999999
pion slit
echmsq1i_set_s | 322.4 |
echmsq2i_set_s | -256.188 |
echmsq3i_set_s | 126.224 |
echmsdimeas2_s | -757.17 |
echmsdb_true_s | -0.680144 |
Rast_TargWidth | |
EHCRT_IXPEAK | 23.8 |
EHCRT_IYPEAK | 11.662 |
EHCRT_ENGERY | |
EHCRT_INITENGERY | |
EHCRT_INITILIMIT | 60 |