    keyword=HMS Dipole Temp

    HMS dipole warning light is flashing due to high LN2 temp. It is currently at
    107.2K. Lassiter reports that it was reading 119K yesterday so appears to be
    oscillating. He thinks that together with the recent vacuum oscillations this
    may be the first signs of a thermal short at the nitrogen shield, which may require
    attention during the next long down.

    Check the nitrogen temp periodically and let Lassiter know if it starts to rise.