Difference between revisions of "Simulation"

From PolWiki
Jump to navigationJump to search
 
(12 intermediate revisions by one other user not shown)
Line 1: Line 1:
==The electron detector==
+
* [[CVS instructions]]
  
* The electron detector is placed 5 mm above the primary electron beam. To check that, I forced the energy of the scattered electrons to be the one of the primary beam (E=1.165 GeV). The figure below demonstrates that the electron detector is effectively located above the primary beam (ignore the photon detector and scattered photons).
+
* [[Patricia]]
  
[[Image:Electron_beam_position.gif|400px]]
+
* [[Amber]]
 
 
 
 
* Then after restoring the scattered electron energy formula, 100 events are generated in the following figures:
 
[[Image:scattered_beam_3.gif|400px]]        -----        [[Image:scattered_beam_1.gif|400px]]
 
 
 
 
 
* A close-up on the electron detector
 
 
 
[[Image:scattered_beam_4.gif|200px]]          -----      [[Image:scattered_beam_2.gif|200px]]
 
 
 
 
 
* Now looking at some distributions and numbers. The simulation was run with the following inputs:
 
    Beam energy = 1.165 GeV
 
    Beam polarization = 80%
 
    Dipole length and height: 125cm x 4.125"
 
    Laser: 532nm, 1kW and alpha_c=35.28 mrad
 
    Nevt generated: 20000
 
 
 
 
 
 
 
{|border="1" cellpadding="5"
 
|-
 
!
 
!Ne
 
|-
 
|no cut
 
|19909
 
|-
 
|require trigger the e detector
 
|16457
 
|-
 
|and cut on k'/kmax min
 
|9612
 
|-
 
|and cut on 4 hits in the e detector
 
|9612
 
|}
 
 
 
[[Image:apower.gif|200px]]
 
 
 
[[Image:egamma_edet.gif|200px]]
 

Latest revision as of 12:10, 15 August 2012