Difference between revisions of "Compton Meeting, August 13, 2013"

From PolWiki
Jump to navigationJump to search
 
(One intermediate revision by the same user not shown)
Line 20: Line 20:
 
=== Laser ===
 
=== Laser ===
  
==Polarimetry plan:==
+
====Polarimetry plan:====
  
 
As the final step in measuring the laser polarization and constraining the uncertainty we aim to measure or   
 
As the final step in measuring the laser polarization and constraining the uncertainty we aim to measure or   
Line 34: Line 34:
 
#  Remove elements used for standard mapping.
 
#  Remove elements used for standard mapping.
 
#  Install the Thorlabs polarimeter head in the interaction region and measure the stokes parameters, including degree of polarization at the maximum circular polarization of both signs.  Spot check other polarizations to check against fit results.  Further characterize polarimeter by measuring the power dependence, angle dependence etc.
 
#  Install the Thorlabs polarimeter head in the interaction region and measure the stokes parameters, including degree of polarization at the maximum circular polarization of both signs.  Spot check other polarizations to check against fit results.  Further characterize polarimeter by measuring the power dependence, angle dependence etc.
## Assuming results make sense, there is no depolarization, we are done.
+
# Check measurement of DOP in-situ directly, by installing a GL polarizer immediately upstream (should get 100% linear, 100% DOP).
## If there is a unrealistic result for DOP (quite possible) then attempt to measure DOP directly after GL polarizer to check device.
+
## Assuming all results make sense, we have measured or bounded the depolarization, we are done.
 
#  (Optional for if Thorlabs polarimeter untrustworthy) We may be able to make some clever measurements with a QWP and only 1 detector.  Need to be smart to aviod this becoming a multi-day effort with a Babinet compensator.
 
#  (Optional for if Thorlabs polarimeter untrustworthy) We may be able to make some clever measurements with a QWP and only 1 detector.  Need to be smart to aviod this becoming a multi-day effort with a Babinet compensator.
  

Latest revision as of 12:59, 19 August 2013

1. Dial Toll-Free Number: 866-740-1260 (U.S. & Canada)
2. International participants dial:
Toll Number: 303-248-0285=
Or International Toll-Free Number: http://www.readytalk.com/intl
3. Enter your 7-digit access code, followed by “#”

 --> our access code is 3227471

Agenda

No meeting room. Call in, or come to Dave's office.

Miscellaneous

  • Need to pick new meeting time
  • Amrendra will come to NN the week of August 26 to help with QWAD removal
  • Need to schedule time to make laser table ready for beamline work.

Laser

Polarimetry plan:

As the final step in measuring the laser polarization and constraining the uncertainty we aim to measure or bound any loss of polarization occurring between the polarizing cube and the interaction point. Assuming that we have remote control of the elements on the table and the previous scan routines work.

This will be done with a Thorlabs polarimeter head. In order to gain confidence in this device, we will expect to see it duplicate the already extracted results for the polarized component.

  1. Run the usual polarization mapping procedure (elements are already installed)
    1. Large scale, coarse steps (to determine the regions of maximum circular polarization and to compare to previous maps.)
    2. Smaller scale, fine steps (to precisely determine the position of maximum circular polarization.)
  2. Remove elements used for standard mapping.
  3. Install the Thorlabs polarimeter head in the interaction region and measure the stokes parameters, including degree of polarization at the maximum circular polarization of both signs. Spot check other polarizations to check against fit results. Further characterize polarimeter by measuring the power dependence, angle dependence etc.
  4. Check measurement of DOP in-situ directly, by installing a GL polarizer immediately upstream (should get 100% linear, 100% DOP).
    1. Assuming all results make sense, we have measured or bounded the depolarization, we are done.
  5. (Optional for if Thorlabs polarimeter untrustworthy) We may be able to make some clever measurements with a QWP and only 1 detector. Need to be smart to aviod this becoming a multi-day effort with a Babinet compensator.

Photon Detector

  • Certifying the Monte Carlo
  • Linearity plans - CH available.
  • Data analysis?

Electron detector