* We are using a stepping motor identified as KML062S04 for vertical motion ([[Media:Edet_motion_motor_KML062S04.pdf | data sheet]] ) of detector using a MDC accuator ( [[Media:MDC_Vacuum_Products_-_Produ...pdf| specifications ]]). This motor is being controlled by a single axis IDC Controller ([[Media:Microstepping_SmartDrives_S6961_UserManual.pdf|User Manual]]) | * We are using a stepping motor identified as KML062S04 for vertical motion ([[Media:Edet_motion_motor_KML062S04.pdf | data sheet]] ) of detector using a MDC accuator ( [[Media:MDC_Vacuum_Products_-_Produ...pdf| specifications ]]). This motor is being controlled by a single axis IDC Controller ([[Media:Microstepping_SmartDrives_S6961_UserManual.pdf|User Manual]]) | ||
− | Current Controller Settings: | + | * Motion Controller: |
− | + | ** Vertically downward motion of the actuator is referred to as 'positive' direction based on the current settings of the controller. | |
− | + | ** All numbers displayed on the controller uses appropriate units of inch and second | |
− | + | **The Actuator has 3 physically verifiable positions which correspond to a switch on the actuator. | |
− | + | *** EOT+ (end of travel switch in positive direction) | |
− | + | *** EOT- (end of travel switch in negative direction) | |
− | + | *** Home | |
− | + | ** Current Controller Settings: | |
− | + | #Current: 1.5A | |
− | + | #Resolution: 18000 | |
− | + | #Inductance: 16 mH | |
− | + | #Direction: positive | |
− | + | #Distance Unit: inch | |
− | + | #Velocity: inch/s | |
− | + | #Acceleration Unit: in/s^2 | |
− | + | #Gear Ratio: (GR) = 25:1 |
Revision as of 08:55, 25 August 2010
- The electron detector is connected to the QWAD using the custom made Flex-cable. The detector is placed inside the vacuum-can whereas the QWAD is placed outside using appropriate flanges used between the Flex-cable and the QWAD. The connection between e-detector and the QWAD (if the vacuum - can was transparent) can be depicted as in the attached picture.
- The electron detector vacuum - can has a motion mechanism to allow us to move the detector vertically in and out of the beam along with the ability to rotate the detector facing the beam. A schematic view of the assembly can be seen here.
- We are using a stepping motor identified as KML062S04 for vertical motion ( data sheet ) of detector using a MDC accuator ( specifications ). This motor is being controlled by a single axis IDC Controller (User Manual)
- Motion Controller:
- Vertically downward motion of the actuator is referred to as 'positive' direction based on the current settings of the controller.
- All numbers displayed on the controller uses appropriate units of inch and second
- The Actuator has 3 physically verifiable positions which correspond to a switch on the actuator.
- EOT+ (end of travel switch in positive direction)
- EOT- (end of travel switch in negative direction)
- Home
- Current Controller Settings:
- Current: 1.5A
- Resolution: 18000
- Inductance: 16 mH
- Direction: positive
- Distance Unit: inch
- Velocity: inch/s
- Acceleration Unit: in/s^2
- Gear Ratio: (GR) = 25:1