Difference between revisions of "Electron Detector DAQ"
From PolWiki
Jump to navigationJump to searchLine 10: | Line 10: | ||
## [[pin mappings in Mezzanine A395D]] | ## [[pin mappings in Mezzanine A395D]] | ||
− | + | == Firmware Revision History == | |
+ | === Slave Board === | ||
+ | |||
All the documented firmware revisions that are updated here, can be found in the SVN mentioning their revision numbers. | All the documented firmware revisions that are updated here, can be found in the SVN mentioning their revision numbers. | ||
#2005: fully working and checked with Readout. | #2005: fully working and checked with Readout. | ||
#2006[Jan 29 '10]: added an added feature of minimum width rejection in the Reconditioning module of the firmware | #2006[Jan 29 '10]: added an added feature of minimum width rejection in the Reconditioning module of the firmware | ||
+ | |||
+ | === Master Board === | ||
+ | #AA07 : unlike v.AA06, the buf_busy signal does not affect the generation of trigger signals from the master board.(needs to be investigated further) |
Revision as of 02:49, 1 October 2010
- Nomenclature Conventions
- Pin Plan of v1495
- Library of functions
- Signal Flow Layout
- Output data structure in CODA
- Generic info: v1495
Firmware Revision History
Slave Board
All the documented firmware revisions that are updated here, can be found in the SVN mentioning their revision numbers.
- 2005: fully working and checked with Readout.
- 2006[Jan 29 '10]: added an added feature of minimum width rejection in the Reconditioning module of the firmware
Master Board
- AA07 : unlike v.AA06, the buf_busy signal does not affect the generation of trigger signals from the master board.(needs to be investigated further)