==Qweak==
+
==General Information==
 +
This is the spot for all things moller polarimetry. Information on how to take moller measurements, spin dance and polarimetry results, and system specs will eventually be put here. This page is currently under construction, and will be updated frequently in the upcoming weeks.
  
Put Qweak results, hardware changes, notes, here!
+
==Moller info for Qweak==
 +
#The Qweak Moller "how to" is officially up and ready for viewing. (version 1, updated jan. 26, 2011): [http://www.jlab.org/~magee/moller/qweak_moller_sbys.v1.pdf Qweak Moller "How-To"]
 +
#The following is a plot showing good tune of the apparatus. It was taken from run 700, hallc:p ~ 1159 MeV, with a 1um target. (Jan. 30, 2011)
 +
 
 +
[[Image:Moller_plot_jan30_2011.png]]
 +
 
 +
==Moller test summaries==
 +
===Jan. 30, 2011===
 +
Today we adjusted the Moller HV, performed a collimator scan, and took some polarization data. See immediately above for a picture of the tune plot. The hallcp_ ~1159 MeV. The full reports can be found in the following Qweak ELOG entries: [https://qweak.jlab.org/elog/Moller/14 Polarization study], [https://qweak.jlab.org/elog/Moller/13 Updated collimator values].
 +
 
 +
The new quad currents and collimator positions are as follows:
 +
 
 +
<pre>
 +
Quad 1: 93 A
 +
Quad 3: 129 A
 +
Col # Position (cm)
 +
1 -1.55
 +
2 -1.55
 +
3 -4.05
 +
4 -4.15
 +
5 Out of beam
 +
6 -3.20
 +
7 -3.20
 +
</pre>
 +
The overall polarization was 89.38 +/- 0.2621%. The real/random ratio (in kHz/uA): 81.
 +
 
 +
<pre>
 +
Run Polarization (%) Comments
 +
702      (-90.07 +- 0.63) New HV L 1510V, R 1535V
 +
703      (-88.75 +- 1.31) New HV L 1510V, R 1535V 
 +
704      (-90.48 +- 0.71)        New HV L 1510V, R 1535V
 +
 +
705      (-89.84 +- 1.15) Old HV L 1480V, R 1520V tripped at end
 +
706      (-89.31 +- 1.09) Old HV L 1480V, R 1520V tripped at end
 +
707      (-89.46 +- 1.52) junk - Not included in the plot
 +
708      (-89.37 +- 0.78) Old HV L 1480V, R 1520V
 +
 +
709      (-89.92 +- 1.50) HV L 1530V, R 1555V
 +
 +
710      (-88.15 +- 0.72) HV L 1610V, R 1655V
 +
711      (-89.77 +- 0.72) HV L 1610V, R 1655V
 +
712      (-88.08 +- 0.72) HV L 1610V, R 1655V
 +
</pre>
 +
 
 +
 
 +
===Jan. 21, 2011===
 +
This was our first straight Moller measurement after the holiday down. Only a series of simple measurements were taken at varying currents were taken, no systematic studies. It was also hoped we could use this data to (eventually) calibrate BCM 17. Notice also the backgrounds remain consistent and reproducible from the December measurements.
 +
 
 +
Conditions: INHWP: In, QE=0.32%, HALLC:p=1159.82 MeV. Collimator 5 was out.
 +
<pre>
 +
Run    Polarization      Note
 +
686    -90.46 +/- 0.52  1 uA
 +
687    -91.36 +/- 0.69  1.5 uA
 +
688    -90.60 +/- 0.67  2.0 uA
 +
689    -91.64 +/- 0.99  1.5 uA
 +
690    -88.56 +/- 1.36  0.5 uA - bad beam position
 +
691    -91.28 +/- 1.43  0.5 uA
 +
</pre>
 +
Excluding run 690, the average polarization is -90.86+/-0.32%.
 +
 
 +
 
 +
 
 +
 
 +
==Spin dances==
 +
The initial Qweak Moller spin dance occurred November 23, 2010. Originally scheduled to coincide with Hall A, beam tune issues (on their end only) prevented a joint study.
 +
 
 +
Test setup: IHWP=OUT, QE=0.35%, Hallc:p 1159.66 MeV +/- 0.03. Solenoid at 3.5T, with 1 um foil.
 +
The current was adjusted using the laser attenuator, slit was wide open. Quoted polarizations are
 +
from the Dave G. scaler-bank-3-only analysis.
 +
 
 +
<pre>
 +
Run  Wein    Polarization      Comments
 +
508  -0.1    40.04 +/- 1.23    200 nA
 +
509  -0.1    40.05 +/- 1.88    1.05 uA
 +
510  -0.1    40.40 +/- 1.03    1 uA
 +
511  -0.1    40.13 +/- 0.68    0.9 uA
 +
512  -0.1    40.19 +/- 0.70    0.9 uA
 +
513  -0.1    40.13 +/- 0.70    0.9 uA
 +
514  -0.1    40.14 +/- 0.65    0.57 uA
 +
515  -0.1    N/A (junk)        Hall C laser off - no Hall A bleedthrough
 +
 
 +
517  +29.0    -2.75 +/- 0.65    0.9 uA
 +
518  +29.0    N/A                Hall C laser off
 +
519  +29.0    -3.70 +/- 0.69    0.9 uA
 +
520  +29.0    -3.48 +/- 0.68    0.9 uA
 +
 
 +
521  -31.0    75.85 +/- 0.88    0.9 uA
 +
522  -31.0    76.81 +/- 0.69    0.9 uA
 +
523  -31.0    75.61 +/- 0.69    0.9 uA
 +
524  -31.0    75.50 +/- 1.25    0.9 uA
 +
525  -31.0    74.54 +/- 0.96    0.9 uA
 +
526  -31.0    75.37 +/- 0.67    0.9 uA
 +
 
 +
527  -75.0    87.89 +/- 0.70    0.9 uA
 +
528  -75.0    87.63 +/- 0.69    0.9 uA
 +
529  -75.0    86.69 +/- 0.69    0.9 uA
 +
530  -75.0    86.83 +/- 0.79    0.9 uA
 +
 
 +
531  -63.20  88.64 +/- 0.74    0.9 uA
 +
532  -63.20  89.65 +/- 1.12    0.9 uA
 +
533  -63.20  90.32 +/- 0.69    0.9 uA
 +
534  -63.20  89.51 +/- 0.68    0.9 uA
 +
535  -63.20  89.73 +/- 1.90    0.9 uA
 +
536  -63.20  90.04 +/- 0.91    0.9 uA
 +
</pre>
 +
 
 +
The ideal horizontal wein angle was calculated to be -63.2 degrees. The measured polarization value at this wein was 89.62 +/- 0.35 (stat)%. Below the fit of polarization vs. Wein angle.
 +
 
 +
[[Image:Pol_vs_wein_dance1.gif|600px]]
 +
 
 +
The original hclog result entries are #208285 and #208394.
 +
 
 +
 
 +
===Moller Commissioning - Nov. 14, 2010===
 +
 
 +
Initial Moller commissioning was on on November 14th, 2010. Polarizations up to 89% occurred. It consisted mainly from runs 476-490. Several targets, currents, and pre-scales were used. Collimator 5 was also removed for several runs to determine if scraping occurred. The following is a run summary:
 +
 
 +
<pre>
 +
Run    target  current(uA)  Camac prescale  Polarization (%)  Comments
 +
477    1um      0.2          100            89.99+/-0.88 
 +
478    1um      0.2          100            88.17+/-0.89 
 +
479    1um      1.0          100            NA              junk
 +
480    1um      1.0          1000          87.20+/-0.69 
 +
481    1um      1.0          1000          88.91+/-0.71 
 +
482    4um      0.2          1000          89.05+/-0.77    collimator 5 out
 +
483    4um      0.2          1000          89.61+/-0.80    collimator 5 out
 +
484    no tgt  1.0          1000          NA              collimator 5 out
 +
485    no tgt  1.0          1000          NA              collimator 5 in
 +
486    1um      0.6          1000          88.68+/-0.80    collimator 5 in
 +
487    1um      0.6          1000          87.95+/-0.82    solenoid at 3.5 T, collimator 5 in
 +
488    1um      0.6          1000          89.12+/-0.90    solenoid at 3.5 T, collimator 5 in
 +
489    1um      0.6          1000          89.69+/-0.80    solenoid at 3.5 T, collimator 5 in, fast raster 2x
 +
490    1um      0.6          1000          89.39+/-0.81    solenoid at 3.5 T, collimator 5 in, fast raster 2x2
 +
491    1um      0.2          1              NA              solenoid at 3.5 T, collimator 5 in, fast raster 2x2
 +
</pre>
 +
 
 +
Also, here is a screen shot of the moller medm screen. Note the Q1 and Q2 currents, and the location of the collimators. This data may change, but should be accurate for the near term.
 +
 
 +
[[Image:Moller_setup_Nov_14_2010.png|600px]]

Revision as of 15:36, 31 January 2011

General Information

This is the spot for all things moller polarimetry. Information on how to take moller measurements, spin dance and polarimetry results, and system specs will eventually be put here. This page is currently under construction, and will be updated frequently in the upcoming weeks.

Moller info for Qweak

  1. The Qweak Moller "how to" is officially up and ready for viewing. (version 1, updated jan. 26, 2011): Qweak Moller "How-To"
  2. The following is a plot showing good tune of the apparatus. It was taken from run 700, hallc:p ~ 1159 MeV, with a 1um target. (Jan. 30, 2011)

Moller plot jan30 2011.png

Moller test summaries

Jan. 30, 2011

Today we adjusted the Moller HV, performed a collimator scan, and took some polarization data. See immediately above for a picture of the tune plot. The hallcp_ ~1159 MeV. The full reports can be found in the following Qweak ELOG entries: Polarization study, Updated collimator values.

The new quad currents and collimator positions are as follows:

Quad 1: 93 A
Quad 3: 129 A
Col #		Position (cm)
1		-1.55
2		-1.55
3		-4.05
4		-4.15
5		Out of beam
6		-3.20
7		-3.20

The overall polarization was 89.38 +/- 0.2621%. The real/random ratio (in kHz/uA): 81.

 Run 		Polarization (%)	Comments
 702      	(-90.07 +- 0.63)	New HV L 1510V, R 1535V 
 703      	(-88.75 +- 1.31)	New HV L 1510V, R 1535V  
 704      	(-90.48 +- 0.71)        New HV L 1510V, R 1535V 
 
 705      	(-89.84 +- 1.15) 	Old HV L 1480V, R 1520V tripped at end
 706      	(-89.31 +- 1.09) 	Old HV L 1480V, R 1520V tripped at end
 707      	(-89.46 +- 1.52)	junk - Not included in the plot
 708      	(-89.37 +- 0.78)	Old HV L 1480V, R 1520V 
 
 709      	(-89.92 +- 1.50)	HV L 1530V, R 1555V
 
 710      	(-88.15 +- 0.72) 	HV L 1610V, R 1655V
 711      	(-89.77 +- 0.72)	HV L 1610V, R 1655V
 712      	(-88.08 +- 0.72)	HV L 1610V, R 1655V


Jan. 21, 2011

This was our first straight Moller measurement after the holiday down. Only a series of simple measurements were taken at varying currents were taken, no systematic studies. It was also hoped we could use this data to (eventually) calibrate BCM 17. Notice also the backgrounds remain consistent and reproducible from the December measurements.

Conditions: INHWP: In, QE=0.32%, HALLC:p=1159.82 MeV. Collimator 5 was out.

Run     Polarization      Note
686     -90.46 +/- 0.52   1 uA
687     -91.36 +/- 0.69   1.5 uA
688     -90.60 +/- 0.67   2.0 uA
689     -91.64 +/- 0.99   1.5 uA
690     -88.56 +/- 1.36   0.5 uA - bad beam position
691     -91.28 +/- 1.43   0.5 uA

Excluding run 690, the average polarization is -90.86+/-0.32%.



Spin dances

The initial Qweak Moller spin dance occurred November 23, 2010. Originally scheduled to coincide with Hall A, beam tune issues (on their end only) prevented a joint study.

Test setup: IHWP=OUT, QE=0.35%, Hallc:p 1159.66 MeV +/- 0.03. Solenoid at 3.5T, with 1 um foil. The current was adjusted using the laser attenuator, slit was wide open. Quoted polarizations are from the Dave G. scaler-bank-3-only analysis.

Run  Wein     Polarization       Comments
508  -0.1     40.04 +/- 1.23     200 nA
509  -0.1     40.05 +/- 1.88     1.05 uA
510  -0.1     40.40 +/- 1.03     1 uA
511  -0.1     40.13 +/- 0.68     0.9 uA
512  -0.1     40.19 +/- 0.70     0.9 uA
513  -0.1     40.13 +/- 0.70     0.9 uA
514  -0.1     40.14 +/- 0.65     0.57 uA
515  -0.1     N/A (junk)         Hall C laser off - no Hall A bleedthrough

517  +29.0    -2.75 +/- 0.65     0.9 uA
518  +29.0    N/A                Hall C laser off
519  +29.0    -3.70 +/- 0.69     0.9 uA
520  +29.0    -3.48 +/- 0.68     0.9 uA

521  -31.0    75.85 +/- 0.88     0.9 uA
522  -31.0    76.81 +/- 0.69     0.9 uA
523  -31.0    75.61 +/- 0.69     0.9 uA
524  -31.0    75.50 +/- 1.25     0.9 uA
525  -31.0    74.54 +/- 0.96     0.9 uA
526  -31.0    75.37 +/- 0.67     0.9 uA

527  -75.0    87.89 +/- 0.70     0.9 uA
528  -75.0    87.63 +/- 0.69     0.9 uA
529  -75.0    86.69 +/- 0.69     0.9 uA
530  -75.0    86.83 +/- 0.79     0.9 uA

531  -63.20   88.64 +/- 0.74     0.9 uA
532  -63.20   89.65 +/- 1.12     0.9 uA
533  -63.20   90.32 +/- 0.69     0.9 uA
534  -63.20   89.51 +/- 0.68     0.9 uA
535  -63.20   89.73 +/- 1.90     0.9 uA
536  -63.20   90.04 +/- 0.91     0.9 uA

The ideal horizontal wein angle was calculated to be -63.2 degrees. The measured polarization value at this wein was 89.62 +/- 0.35 (stat)%. Below the fit of polarization vs. Wein angle.

Pol vs wein dance1.gif

The original hclog result entries are #208285 and #208394.


Moller Commissioning - Nov. 14, 2010

Initial Moller commissioning was on on November 14th, 2010. Polarizations up to 89% occurred. It consisted mainly from runs 476-490. Several targets, currents, and pre-scales were used. Collimator 5 was also removed for several runs to determine if scraping occurred. The following is a run summary:

Run    target  current(uA)  Camac prescale  Polarization (%)  Comments
477     1um      0.2          100            89.99+/-0.88  
478     1um      0.2          100            88.17+/-0.89  
479     1um      1.0          100            NA               junk
480     1um      1.0          1000           87.20+/-0.69  
481     1um      1.0          1000           88.91+/-0.71  
482     4um      0.2          1000           89.05+/-0.77     collimator 5 out
483     4um      0.2          1000           89.61+/-0.80     collimator 5 out
484     no tgt   1.0          1000           NA               collimator 5 out
485     no tgt   1.0          1000           NA               collimator 5 in
486     1um      0.6          1000           88.68+/-0.80     collimator 5 in
487     1um      0.6          1000           87.95+/-0.82     solenoid at 3.5 T, collimator 5 in
488     1um      0.6          1000           89.12+/-0.90     solenoid at 3.5 T, collimator 5 in
489     1um      0.6          1000           89.69+/-0.80     solenoid at 3.5 T, collimator 5 in, fast raster 2x
490     1um      0.6          1000           89.39+/-0.81     solenoid at 3.5 T, collimator 5 in, fast raster 2x2
491     1um      0.2          1              NA               solenoid at 3.5 T, collimator 5 in, fast raster 2x2

Also, here is a screen shot of the moller medm screen. Note the Q1 and Q2 currents, and the location of the collimators. This data may change, but should be accurate for the near term.

Moller setup Nov 14 2010.png